{"product_id":"aims-power-1000-watt-12-volt-low-frequency-pure-sine-power-inverter","title":"AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-1000-watt-low-frequency-pure-sine-inverter-with-gfci-receptacle-output-breaker-and-remote-port-on-its-end-panel.jpg\" alt=\"AIMS Power 1000 Watt low frequency pure sine inverter with GFCI receptacle, output breaker and remote port on its end panel\" width=\"795\" height=\"623\" style=\"display: block; width: 100%; max-width: 795px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Runs Sensitive Electronics and Starts Tools With a 3000W Surge\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter converts a 12V battery bank into 120V AC pure sine power with a true neutral, at 1000W continuous. Its low frequency transformer design gives it a 3000W surge for up to 20 seconds, and AIMS lists it as capable of running a 1.0HP electric motor. It is ETL listed to UL 458.\u003c\/p\u003e\n\u003cp\u003eAIMS designed it for mobile work vehicles, off-grid systems and field installations that need clean power for electronics plus enough surge for motors and compressors. Loads plug into a GFCI duplex receptacle on the end panel, since this model has no hardwire terminal block. If the inverter ends up mounted somewhere hard to reach, an optional wired LCD remote or Bluetooth dongle lets you keep an eye on it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Features\u003c\/h3\u003e\n\u003ch4\u003e3000W of Surge for Motor Starts\u003c\/h4\u003e\n\u003cp\u003eThe surge rating is 300% of continuous power for up to 20 seconds, which helps motors, compressors and heavy equipment start. Above 1000W, the inverter runs 110% to 125% load for 15 minutes, 125% to 150% for 1 minute and up to 300% for 20 seconds, then shuts down. It beeps before it trips.\u003c\/p\u003e\n\u003ch4\u003eClean Output for Electronics\u003c\/h4\u003e\n\u003cp\u003eDigital Signal Processing (DSP) keeps the 120VAC output within ±10% RMS as battery voltage drifts. AIMS lists THD as typically under 3% and 10% at most under full linear load, with nominal efficiency up to 88% and a 92% peak. Output frequency is 50 or 60Hz, set by DIP switch.\u003c\/p\u003e\n\u003ch4\u003eRemote Monitoring From Up to 60 Feet\u003c\/h4\u003e\n\u003cp\u003eThe optional REMOTELF wired LCD remote plugs into the LCD RMT port with up to 60 feet of cable. It shows battery voltage, output voltage, output frequency, output load, battery capacity and fault codes, and it can turn the inverter on, off or into power saver. AIMS also lists an optional BT-AIMS-PRO Bluetooth dongle.\u003c\/p\u003e\n\u003ch4\u003eGFCI Protected Outlets\u003c\/h4\u003e\n\u003cp\u003eA GFCI duplex receptacle gives you two outlets, and a GFCI output circuit breaker sits beside it. Tri-color LEDs on the inverter show inverter mode, battery level and load level at a glance.\u003c\/p\u003e\n\u003ch4\u003eSettings You Choose With DIP Switches\u003c\/h4\u003e\n\u003cp\u003eFour DIP switches set the low battery alarm and trip pair (10.5\/10.0Vdc, 11.0\/10.5Vdc, 11.5\/11.0Vdc or 12.5\/12.0Vdc), how often power saver mode searches for a load (every 3 or 30 seconds) and the 50 or 60Hz output.\u003c\/p\u003e\n\u003ch4\u003eProtection and a Coated Build\u003c\/h4\u003e\n\u003cp\u003eShort circuit protection limits current and faults after 1 second. The inverter also guards against overload, low and high battery voltage, a locked fan and heat sink temperatures of 221°F (105°C) or more. Conformal coated circuit boards resist water, rust, dust and corrosion, and a 3-step fan adjusts to temperature and load.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMobile work vehicles.\u003c\/strong\u003e Run laptops, drills and other corded tools from a 12V bank in a service van or utility truck.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOffice gear on the road.\u003c\/strong\u003e AIMS lists computers, printers, monitors, routers and scanners among the loads the PILF series can run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid and solar systems.\u003c\/strong\u003e Give a 12V battery system pure sine AC for small appliances and electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHome backup.\u003c\/strong\u003e Keep lights, fans, a TV and a router running from a battery bank during an outage.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003ePILF10W12V120V Versus a Modified Sine Inverter\u003c\/h4\u003e\n\u003cp\u003eA modified sine inverter makes a stepped waveform that some electronics, chargers and motors don't handle well. This inverter puts out a pure sine wave close to utility power, so one unit can run your electronics and your tools.\u003c\/p\u003e\n\u003ch4\u003eLow Frequency Versus High Frequency Design\u003c\/h4\u003e\n\u003cp\u003eA low frequency inverter relies on a heavy transformer, which is why this model weighs 26 lbs and holds 300% surge for 20 seconds. AIMS says the design helps with power equipment and other inductive loads. A high frequency inverter is usually lighter, which can make sense when your loads have little startup surge.\u003c\/p\u003e\n\u003ch4\u003ePlug-In Outlets Versus a Hardwire Inverter\u003c\/h4\u003e\n\u003cp\u003eThis model is plug-in only, which keeps installation simple for cord-connected loads. If you need to feed a subpanel or hardwired circuits, look at an inverter with a hardwire terminal block instead.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003ePlan Around 500W for Long Runs\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says not to run the output at 100% for long periods. For runs over an hour, keep the load at 50% or less to prolong the inverter's life, which is 500W on this model. Use the surge for startups, and switch loads on one at a time.\u003c\/p\u003e\n\u003ch4\u003eCable, Fuse and Ground\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the DC input at 12Vdc and 100Adc. Its chart suggests at least 4 AWG cable with a 100A fuse for runs up to 5 feet and for 5 to 10 feet. Keep the battery within 10 feet, use larger cable for longer runs, and ground the chassis with 8 AWG or larger copper wire. AIMS suggests 17 Nm (12.6 lb-ft) of torque on the DC terminals.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou run electronics and tools from one 12V bank\u003c\/li\u003e\n\u003cli\u003eYour steady loads sit well under 1000W\u003c\/li\u003e\n\u003cli\u003eThe inverter will be mounted out of reach\u003c\/li\u003e\n\u003cli\u003eYou don't need a hardwire connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhy Doesn't Power Saver Mode Wake Up for Small Loads?\u003c\/h4\u003e\n\u003cp\u003eIn Power Saver Auto, a load must be resistive and over 50W to bring the inverter to full output. Small fluorescent lights and some electronics can't be detected, so AIMS recommends the Power On setting for those loads.\u003c\/p\u003e\n\u003ch4\u003eWhat Happens When the Battery Runs Low?\u003c\/h4\u003e\n\u003cp\u003eThe inverter beeps at your chosen alarm point and stops at the trip point. Once the battery recovers to 13.0Vdc with the switch still on, it restarts by itself, so AIMS warns not to leave loads such as heaters unattended.\u003c\/p\u003e\n\u003ch4\u003eCan I Connect the Output to Shore Power or a Generator?\u003c\/h4\u003e\n\u003cp\u003eNo. AIMS says the AC output must never be tied to utility power or a generator, because that will damage the inverter. This model has no AC input, transfer switch or built-in charger.\u003c\/p\u003e\n\u003ch4\u003eWhy Does the Inverter Hum With Some Loads?\u003c\/h4\u003e\n\u003cp\u003eHalf wave loads such as hair dryers and some inductive loads can make the transformer or case vibrate. AIMS says the noise doesn't harm the inverter or the load.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Red DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Black DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e2 x Flange Nuts (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e4 x Phillips Screws (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eClean Power for Mobile Work and Backup\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter combines a 3000W surge, DSP voltage control, GFCI outlets and optional remote monitoring in a conformal coated, ETL listed package. For help matching it to your loads and battery bank, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003ePILF10W12V120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000W for 20 seconds (300%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapable of Electric Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz (DIP switch selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;3%, max 10% under full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9-1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GFCI duplex receptacle (2 outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGFCI Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC, 60Hz, 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI output circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12Vdc \/ 100Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.0Vdc \/ 11.5Vdc \/ 12.5Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc \/ 10.5Vdc \/ 11.0Vdc \/ 12.0Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Voltage Recover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥13.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Alarm and Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥16.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Input Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdle Consumption, Search Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5W in Power Saver On mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Wake-Up Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 50W resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Search Pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery 3s or 30s (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, Up to 5 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AWG with 100A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, 5 to 10 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AWG with 100A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter to Battery Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 10 ft (larger cable beyond 10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5-20.5 Nm (9.25-15.19 lb-ft), 17 Nm (12.6 lb-ft) suggested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, current limit function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 110% to 125%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 125% to 150%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 150% to 300%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat sink ≥221°F (105°C), shuts down after 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Protections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow and high battery voltage alarm, fan lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, on circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eControls and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower On \/ Power Off \/ Power Saver Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-color LEDs (inverter mode, battery level, load level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional REMOTELF wired LCD remote (LCD RMT port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (18 m) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Remote Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery voltage, output voltage, output frequency, output load, fault code, battery capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional BT-AIMS-PRO dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (low battery set points, power saver search, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step intelligent fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 dB at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 x 7.1 x 5.4 in (385 x 181 x 136 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 lbs (11.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 x 9.1 x 8.3 in (495 x 230 x 210 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6 lbs (12.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted or flat placement, any orientation except upside down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Bolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 1\/4-20 steel bolts with flat and lock washers and nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 in around the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Surface Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 176°F (80°C) in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG or larger copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed to UL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-pilf-man-071725.pdf\" title=\"AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-1000-watt-12-volt-low-frequency-pure-sine-power-inverter-manual.jpg\" alt=\"AIMS Power 1000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662699364601,"sku":"PILF10W12V120V","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-1000-watt-12-volt-low-frequency-pure-sine-power-inverter-angled-view-of-the-ac-end-with-gfci-outlet.jpg?v=1794358945","url":"https:\/\/outboundpower.com\/products\/aims-power-1000-watt-12-volt-low-frequency-pure-sine-power-inverter","provider":"Outbound Power","version":"1.0","type":"link"}