{"product_id":"aims-power-1500-watt-12-volt-low-frequency-pure-sine-power-inverter","title":"AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-1500-watt-low-frequency-pure-sine-inverter-showing-its-dc-battery-terminals-cooling-fan-and-blue-steel-case.jpg\" alt=\"AIMS Power 1500 Watt low frequency pure sine inverter showing its DC battery terminals, cooling fan and blue steel case\" width=\"886\" height=\"622\" style=\"display: block; width: 100%; max-width: 886px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter Delivers a 4500W Surge to Start Pumps and Shop Tools on 12V Power\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter is a PILF series inverter that changes 12V DC battery power into clean 120V AC with a true neutral. It runs 1500W continuously, holds a 4500W surge for up to 20 seconds and is listed by AIMS as capable of running a 1.5HP electric motor. It is ETL listed to UL 458.\u003c\/p\u003e\n\u003cp\u003eAIMS aims it at service trucks, mobile workshops, off-grid homes and field installations, where tools, pumps and mid-size appliances share power with sensitive electronics. You plug loads into a GFCI duplex receptacle on the end panel. It is an inverter only, with no AC input, transfer switch or built-in charger, so it works alongside whatever charging your battery bank already has.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter Features\u003c\/h3\u003e\n\u003ch4\u003eSurge Sized for Pumps and Compressors\u003c\/h4\u003e\n\u003cp\u003eMotors and compressors need extra power for a moment as they start. This inverter carries up to 300% of its rating, 4500W, for 20 seconds. Smaller overloads last longer: 110% to 125% for 15 minutes and 125% to 150% for 1 minute, with a beeping alarm before the inverter shuts down.\u003c\/p\u003e\n\u003ch4\u003eSteady Voltage as the Battery Drains\u003c\/h4\u003e\n\u003cp\u003eA DSP (Digital Signal Processing) controller holds the 120VAC output within ±10% RMS while battery voltage falls under load. THD is typically under 3% and at most 10% under full linear load, so electronics get clean power alongside your tools.\u003c\/p\u003e\n\u003ch4\u003eTwo GFCI Outlets on the End Panel\u003c\/h4\u003e\n\u003cp\u003eThe AC end has a GFCI duplex receptacle with two outlets, a GFCI output circuit breaker, the LCD remote port and four DIP switches. There's no hardwire terminal block on this model. Tri-color LEDs show inverter mode, battery level and load level.\u003c\/p\u003e\n\u003ch4\u003ePower Saver Mode for Light Days\u003c\/h4\u003e\n\u003cp\u003eIn Power Saver Auto, the inverter idles at less than 2.5W and pulses the output every 3 or 30 seconds to look for a load. A resistive load over 50W brings it to full output, and it drops back to search mode when the load turns off.\u003c\/p\u003e\n\u003ch4\u003eFan Control That Follows Heat and Load\u003c\/h4\u003e\n\u003cp\u003eThe 3-step fan stays off at light load and low heat sink temperature, then steps to 50% and 100% speed as heat or load rises. AIMS rates fan noise under 60 dB at 1 meter. If the heat sink reaches 221°F (105°C), the inverter shuts its output down after 30 seconds.\u003c\/p\u003e\n\u003ch4\u003eCoated Boards for Dust and Salty Air\u003c\/h4\u003e\n\u003cp\u003eEvery PILF inverter gets a conformal coating on its circuit boards, which AIMS says makes them resistant to water, rust, dust and corrosion, including salty air. AIMS also says the units are not splash proof, so mount it somewhere dry.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eService trucks and mobile workshops.\u003c\/strong\u003e Run drills, grinders, sanders and buffers from the truck's 12V battery bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater pumps.\u003c\/strong\u003e Start and run pumps and variable speed motors that need a strong push at startup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid homes.\u003c\/strong\u003e Power kitchen appliances, lights and electronics from a 12V battery system, within the 1500W rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackup power.\u003c\/strong\u003e Keep essential plug-in loads running from a battery bank when the grid goes down.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003ePILF15W12V120V Versus a High Frequency Inverter\u003c\/h4\u003e\n\u003cp\u003eThe PILF's heavy transformer is what lets it hold 300% surge for 20 seconds, and AIMS says this design suits power equipment and other inductive loads. That transformer also makes it heavier at 33 lbs. A high frequency inverter is usually lighter, which can suit electronics-only setups with little startup surge.\u003c\/p\u003e\n\u003ch4\u003ePure Sine Versus a Modified Sine Inverter\u003c\/h4\u003e\n\u003cp\u003eModified sine inverters make a stepped waveform that some motors, chargers and electronics don't run well on. The PILF15W12V120V makes a pure sine wave much like utility power, so pumps, tools and electronics can share one inverter.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eKeep Long Runs at 750W or Less\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says not to run the output at 100% continuously. For loads that run longer than an hour, keep them at 50% or less, which is 750W here, to prolong the inverter's life. Turn the inverter on first, wait a few seconds, then switch loads on one at a time.\u003c\/p\u003e\n\u003ch4\u003eBattery Bank and Cables\u003c\/h4\u003e\n\u003cp\u003eAIMS says battery capacity, cable size and fuse size all decide whether the inverter can deliver the power you need. This model is rated 12Vdc at 150Adc, and AIMS's chart suggests at least 4 AWG cable with a 150A fuse for runs up to 5 feet and from 5 to 10 feet. Keep the battery within 10 feet, and twist the DC cables or tape them together to cut interference and inductance.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need to start pumps, compressors or shop tools\u003c\/li\u003e\n\u003cli\u003eYour steady load stays near 750W or below\u003c\/li\u003e\n\u003cli\u003ePlug-in GFCI outlets cover your wiring needs\u003c\/li\u003e\n\u003cli\u003eYou want pure sine power from a 12V bank\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat Do the LED Lights Mean?\u003c\/h4\u003e\n\u003cp\u003eEach of the three LEDs uses green, yellow and red. Inverter mode shows normal, alarm or fault. Battery level shows normal, low or high voltage. Load level shows 0% to 50% load in green, 50% to 100% in yellow and overload in red.\u003c\/p\u003e\n\u003ch4\u003eHow Do I Reset It After a Fault?\u003c\/h4\u003e\n\u003cp\u003eAfter an over temperature or overload shutdown, clear the cause, turn the power switch off, wait 5 seconds and turn it back on.\u003c\/p\u003e\n\u003ch4\u003eCan It Go in the Same Compartment as My Batteries?\u003c\/h4\u003e\n\u003cp\u003eNo. The inverter has capacitors that can spark when first connected, and some batteries vent gases. Mount it on a secure surface as close to the batteries as you can, but outside their compartment and with good ventilation.\u003c\/p\u003e\n\u003ch4\u003eIs It Reverse Polarity Protected?\u003c\/h4\u003e\n\u003cp\u003eNo. Reversed battery cables cause permanent damage that AIMS does not cover, so double-check polarity before connecting.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Red DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Black DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e2 x Flange Nuts (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e4 x Phillips Screws (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eStrong Startup Power for Tools and Pumps\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter gives your 12V system a 4500W surge, steady DSP regulated output and two GFCI outlets in a coated, ETL listed case. If you'd like help sizing a battery bank or choosing cables and fuses, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003ePILF15W12V120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4500W for 20 seconds (300%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapable of Electric Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz (DIP switch selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;3%, max 10% under full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9-1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GFCI duplex receptacle (2 outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGFCI Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC, 60Hz, 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI output circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12Vdc \/ 150Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.0Vdc \/ 11.5Vdc \/ 12.5Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc \/ 10.5Vdc \/ 11.0Vdc \/ 12.0Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Voltage Recover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥13.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Alarm and Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥16.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Input Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdle Consumption, Search Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5W in Power Saver On mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Wake-Up Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 50W resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Search Pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery 3s or 30s (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, Up to 5 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AWG with 150A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, 5 to 10 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AWG with 150A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter to Battery Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 10 ft (larger cable beyond 10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5-20.5 Nm (9.25-15.19 lb-ft), 17 Nm (12.6 lb-ft) suggested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, current limit function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 110% to 125%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 125% to 150%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 150% to 300%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat sink ≥221°F (105°C), shuts down after 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Protections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow and high battery voltage alarm, fan lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, on circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eControls and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower On \/ Power Off \/ Power Saver Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-color LEDs (inverter mode, battery level, load level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional REMOTELF wired LCD remote (LCD RMT port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (18 m) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Remote Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery voltage, output voltage, output frequency, output load, fault code, battery capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional BT-AIMS-PRO dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (low battery set points, power saver search, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step intelligent fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 dB at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 x 7.1 x 5.4 in (385 x 181 x 136 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 lbs (14.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 x 9.1 x 8.3 in (495 x 230 x 210 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.2 lbs (15.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted or flat placement, any orientation except upside down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Bolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 1\/4-20 steel bolts with flat and lock washers and nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 in around the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Surface Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 176°F (80°C) in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG or larger copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed to UL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-pilf-man-071725.pdf\" title=\"AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-1500-watt-12-volt-low-frequency-pure-sine-power-inverter-manual.jpg\" alt=\"AIMS Power 1500 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662686847225,"sku":"PILF15W12V120V","price":660.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-1500-watt-12-volt-low-frequency-pure-sine-power-inverter-angled-from-the-battery-end-with-rating-label-on-the-side.jpg?v=1794358689","url":"https:\/\/outboundpower.com\/products\/aims-power-1500-watt-12-volt-low-frequency-pure-sine-power-inverter","provider":"Outbound Power","version":"1.0","type":"link"}