{"product_id":"aims-power-2000-watt-12-volt-low-frequency-pure-sine-power-inverter","title":"AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/front-view-of-the-aims-power-2000-watt-low-frequency-pure-sine-inverter-with-power-switch-cooling-fan-and-hardwire-ac-terminal.jpg\" alt=\"Front view of the AIMS Power 2000 Watt low frequency pure sine inverter with power switch, cooling fan and hardwire AC terminal\" width=\"824\" height=\"696\" style=\"display: block; width: 100%; max-width: 824px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Adds a Hardwire AC Terminal and 6000W of Surge for Panel-Fed 12V Systems\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter converts 12V battery power into 120V AC pure sine power with a true neutral at 2000W continuous. Its low frequency design holds a 6000W surge for up to 20 seconds, and AIMS lists it as capable of running a 2.0HP electric motor. It is ETL listed to UL 458.\u003c\/p\u003e\n\u003cp\u003eThis model gives you two ways to connect. A hardwire AC terminal block lets you reach the inverter's full output capacity and feed a sub-panel or built-in circuits, while a GFCI duplex receptacle on the side handles quick plug-in loads. AIMS built it for work trucks and mobile setups, off-grid systems and backup power, whether a professional or the owner does the install.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Features\u003c\/h3\u003e\n\u003ch4\u003eHardwire Terminal for Full Output\u003c\/h4\u003e\n\u003cp\u003eThe AC terminal block takes ground, line and neutral wires from 8 to 20 AWG, and AIMS recommends 10 to 8 AWG. A terminal output circuit breaker on the front panel protects that connection. AIMS points to the hardwire terminal as the way to use the inverter's full output capacity.\u003c\/p\u003e\n\u003ch4\u003eGFCI Outlets on the Side Panel\u003c\/h4\u003e\n\u003cp\u003eA GFCI duplex receptacle gives you two outlets for tools and appliances, with its own GFCI output circuit breaker on the front panel. It's handy for a quick plug-in load even when the main output is hardwired.\u003c\/p\u003e\n\u003ch4\u003e6000W Surge for Motor Starts\u003c\/h4\u003e\n\u003cp\u003eThe 300% surge rating gives motors, compressors and pumps up to 20 seconds to start. For smaller overloads, the inverter runs 110% to 125% load for 15 minutes and 125% to 150% for 1 minute before it shuts down, beeping first as a warning.\u003c\/p\u003e\n\u003ch4\u003eDSP Regulated Pure Sine Output\u003c\/h4\u003e\n\u003cp\u003eDigital Signal Processing keeps the 120VAC output within ±10% RMS as battery voltage changes. AIMS lists THD as typically under 3% and 10% at most under full linear load. A DIP switch sets the output to 50 or 60Hz.\u003c\/p\u003e\n\u003ch4\u003eControls Grouped on the Front Panel\u003c\/h4\u003e\n\u003cp\u003eThe power switch (Power On, Power Off or Power Saver Auto), tri-color LEDs, LCD RMT port and DIP switches sit together on the front panel. Add the optional REMOTELF wired LCD remote on up to 60 feet of cable to watch battery voltage, load and fault codes from another spot. AIMS also lists an optional BT-AIMS-PRO Bluetooth dongle.\u003c\/p\u003e\n\u003ch4\u003eLow Idle Draw and Coated Electronics\u003c\/h4\u003e\n\u003cp\u003eIn Power Saver Auto, idle draw drops below 2.5W until a resistive load over 50W appears. Conformal coated circuit boards resist water, rust, dust and corrosion, and a 3-step fan matches cooling to heat and load.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWork trucks with built-in circuits.\u003c\/strong\u003e Feed the AC outlets wired into a service body or mobile workshop through the hardwire terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid cabins.\u003c\/strong\u003e Supply a small sub-panel from a 12V battery bank for lights, appliances and electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompressors and pumps.\u003c\/strong\u003e Start air compressors, water pumps and other motor loads that need a big push at startup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery backup circuits.\u003c\/strong\u003e Run a dedicated set of essential circuits from batteries, kept fully separate from utility power.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003ePILF20W12V120V Versus an Outlet-Only Inverter\u003c\/h4\u003e\n\u003cp\u003eAn outlet-only inverter limits you to plug-in cords. This model adds a hardwire terminal block, so it can feed a sub-panel or permanent wiring, and it keeps a GFCI duplex receptacle for convenience.\u003c\/p\u003e\n\u003ch4\u003eLow Frequency Versus High Frequency Inverter\u003c\/h4\u003e\n\u003cp\u003eThe PILF's transformer-based design is what lets it hold 300% surge for 20 seconds, and AIMS says that suits power equipment and inductive loads. It also adds weight, at 47.5 lbs for this model. A high frequency inverter is usually lighter, which can suit loads with little startup surge.\u003c\/p\u003e\n\u003ch4\u003ePILF20W12V120V Versus an Inverter Charger\u003c\/h4\u003e\n\u003cp\u003eAn inverter charger adds an AC input, a charger and automatic transfer. This model has none of those, so it suits systems where solar, an alternator or a separate charger keeps the batteries up and the inverter stays off the grid.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eSize for 1000W of Long-Running Load\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says not to run the output at 100% continuously. For loads that run longer than an hour, keep them at 50% or less to prolong the inverter's life, which is 1000W on this model. Use the surge headroom for startups, and switch loads on one at a time.\u003c\/p\u003e\n\u003ch4\u003eDC Cable and Fuse for a 200A Input\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the DC input at 12Vdc and 200Adc. For cable runs up to 5 feet, its chart suggests at least 1\/0 AWG with a 200A fuse, and from 5 to 10 feet, 2\/0 AWG with a 200A fuse. Keep the battery within 10 feet, torque the DC terminals to about 17 Nm (12.6 lb-ft) and ground the chassis with 8 AWG or larger copper wire.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou want to hardwire 120V circuits to a 12V bank\u003c\/li\u003e\n\u003cli\u003eYour loads include compressors, pumps or motors\u003c\/li\u003e\n\u003cli\u003eYour steady load stays near 1000W\u003c\/li\u003e\n\u003cli\u003eYou charge your batteries with separate equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWho Should Wire the Hardwire Terminal?\u003c\/h4\u003e\n\u003cp\u003eAIMS says wiring should meet all local codes and be done by qualified personnel such as a licensed electrician, following the National Electric Code or Canadian Electrical Code. Damage caused by AC wiring mistakes isn't covered, and AIMS warns not to loosen or touch the rear set screws on the terminal block.\u003c\/p\u003e\n\u003ch4\u003eCan I Use It in an RV?\u003c\/h4\u003e\n\u003cp\u003eAIMS notes that the AC terminal output is not ground fault protected and that RV installations require GFCI protection of certain branch circuits. Plan that protection into your RV wiring and follow all applicable codes.\u003c\/p\u003e\n\u003ch4\u003eCan the Output Connect to My Home's Wiring?\u003c\/h4\u003e\n\u003cp\u003eAIMS says the AC output must never be connected to utility power or a generator, because power fed back into the inverter will damage it instantly and may create a fire hazard. Any circuits it feeds must stay separate from those sources.\u003c\/p\u003e\n\u003ch4\u003eIs It Reverse Polarity Protected?\u003c\/h4\u003e\n\u003cp\u003eNo. Reversed battery cables cause permanent damage that AIMS does not cover, so confirm polarity with the inverter and loads off before you connect.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Red DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Black DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x AC Terminal Block Cover With 2 Phillips Screws\u003c\/li\u003e\n\u003cli\u003e2 x Flange Nuts (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e4 x Phillips Screws (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eFlexible AC Wiring From a 12V Bank\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter pairs a hardwire terminal and GFCI outlets with a 6000W surge and DSP regulated pure sine output. If you'd like help planning cables, fuses or AC wiring for your system, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003ePILF20W12V120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000W for 20 seconds (300%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapable of Electric Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz (DIP switch selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;3%, max 10% under full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9-1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GFCI duplex receptacle (2 outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGFCI Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC, 60Hz, 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, AC terminal block (ground, L, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Terminal Wire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 20 AWG (10 to 8 AWG recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Terminal Ground Fault Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal output circuit breaker and GFCI output circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12Vdc \/ 200Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.0Vdc \/ 11.5Vdc \/ 12.5Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc \/ 10.5Vdc \/ 11.0Vdc \/ 12.0Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Voltage Recover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥13.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Alarm and Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥16.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Input Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdle Consumption, Search Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5W in Power Saver On mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Wake-Up Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 50W resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Search Pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery 3s or 30s (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, Up to 5 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG with 200A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, 5 to 10 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0 AWG with 200A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter to Battery Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 10 ft (larger cable beyond 10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5-20.5 Nm (9.25-15.19 lb-ft), 17 Nm (12.6 lb-ft) suggested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, current limit function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 110% to 125%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 125% to 150%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 150% to 300%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat sink ≥221°F (105°C), shuts down after 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Protections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow and high battery voltage alarm, fan lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, on circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eControls and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower On \/ Power Off \/ Power Saver Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-color LEDs (inverter mode, battery level, load level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional REMOTELF wired LCD remote (LCD RMT port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (18 m) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Remote Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery voltage, output voltage, output frequency, output load, fault code, battery capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional BT-AIMS-PRO dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (low battery set points, power saver search, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step intelligent fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 dB at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.9 x 13.5 x 7.2 in (480 x 344 x 184 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.5 lbs (21.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.2 x 17.5 x 10.6 in (590 x 445 x 270 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.1 lbs (24.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted or flat placement, any orientation except upside down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Bolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 1\/4-20 steel bolts with flat and lock washers and nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 in around the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Surface Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 176°F (80°C) in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG or larger copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed to UL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-pilf-man-071725.pdf\" title=\"AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-2000-watt-12-volt-low-frequency-pure-sine-power-inverter-manual.jpg\" alt=\"AIMS Power 2000 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662693662969,"sku":"PILF20W12V120V","price":765.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-2000-watt-12-volt-low-frequency-pure-sine-power-inverter-front-panel-with-dc-terminals-fan-breakers-and-ac-terminal-block.jpg?v=1794358785","url":"https:\/\/outboundpower.com\/products\/aims-power-2000-watt-12-volt-low-frequency-pure-sine-power-inverter","provider":"Outbound Power","version":"1.0","type":"link"}