{"product_id":"aims-power-2400-watt-12-volt-low-frequency-pure-sine-power-inverter","title":"AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-2400-watt-low-frequency-pure-sine-inverter-seen-head-on-with-its-terminal-output-and-gfci-output-circuit-breakers.jpg\" alt=\"AIMS Power 2400 Watt low frequency pure sine inverter seen head-on with its terminal output and GFCI output circuit breakers\" width=\"824\" height=\"696\" style=\"display: block; width: 100%; max-width: 824px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter Handles 7200W Startup Loads Like Air Compressors From a 12V Battery Bank\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter delivers 2400W of continuous 120VAC pure sine power with a true neutral from a 12V battery bank. Its low frequency transformer design gives it a 7200W surge for up to 20 seconds, and AIMS lists it as capable of running a 2.4HP electric motor. It is ETL listed to UL 458.\u003c\/p\u003e\n\u003cp\u003eIt is meant for mobile, off-grid and backup systems that run compressors, pumps and motors alongside appliances and sensitive electronics. Output comes through a hardwire terminal block for the inverter's full capacity or a GFCI duplex receptacle for plug-in loads. AIMS points to simple installation and flexible mounting, so it suits professional installers and first-time off-grid owners alike.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter Features\u003c\/h3\u003e\n\u003ch4\u003eA 7200W Surge Window\u003c\/h4\u003e\n\u003cp\u003eUp to 300% of rated power is available for 20 seconds, which gives compressors and other motor loads time to come up to speed. Lighter overloads last longer, with 110% to 125% allowed for 15 minutes and 125% to 150% for 1 minute. AIMS notes that surges make extra heat and lower efficiency.\u003c\/p\u003e\n\u003ch4\u003eTwo Output Options\u003c\/h4\u003e\n\u003cp\u003eA three-position AC terminal block (ground, L and N) accepts 8 to 20 AWG wire, with 10 to 8 AWG recommended, and is protected by a terminal output circuit breaker. A GFCI duplex receptacle on the side gives you two outlets with their own GFCI output circuit breaker.\u003c\/p\u003e\n\u003ch4\u003eVoltage That Holds as Batteries Sag\u003c\/h4\u003e\n\u003cp\u003eDSP (Digital Signal Processing) control keeps output within ±10% RMS as battery voltage drops under heavy load. THD is typically under 3%, with a 10% maximum under full linear load. The inverter starts at 10.0Vdc and raises an alarm and fault at 16.0Vdc or higher.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Settings You Pick\u003c\/h4\u003e\n\u003cp\u003eDIP switches set the low battery alarm and trip pair to 10.5\/10.0Vdc, 11.0\/10.5Vdc, 11.5\/11.0Vdc or 12.5\/12.0Vdc. Once the battery recovers to 13.0Vdc, the inverter restarts on its own if the switch is still on.\u003c\/p\u003e\n\u003ch4\u003eFan Cooling and Heat Protection\u003c\/h4\u003e\n\u003cp\u003eA 3-step fan adjusts speed to heat sink temperature and load and stays under 60 dB at 1 meter. If the heat sink reaches 221°F (105°C), the inverter shuts down its output after 30 seconds. Conformal coated circuit boards resist water, rust, dust and corrosion.\u003c\/p\u003e\n\u003ch4\u003eOptional Remote and Bluetooth Monitoring\u003c\/h4\u003e\n\u003cp\u003eAIMS lists two optional monitoring add-ons for this model, the REMOTELF wired LCD remote and the BT-AIMS-PRO Bluetooth dongle. The LCD remote connects to the LCD RMT port on up to 60 feet of cable and shows battery voltage, output voltage, frequency, load, battery capacity and fault codes.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eService trucks with air compressors.\u003c\/strong\u003e Start and run a compressor and power tools from the truck's 12V battery bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid workshops.\u003c\/strong\u003e Run circular saws, grinders and other shop tools from a battery bank wired to a small panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePumps and motors.\u003c\/strong\u003e Handle pump and motor loads that pull hard for a moment at startup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid homes and backup.\u003c\/strong\u003e Power appliances and electronics from a 12V battery system during outages or full time.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eHardwire Terminal Versus GFCI Outlets\u003c\/h4\u003e\n\u003cp\u003eUse the hardwire terminal when you want to feed a sub-panel or built-in circuits and reach the inverter's full output capacity. The GFCI outlets are quicker for cord-connected tools. AIMS notes the hardwire output is not ground fault protected, so plan any required GFCI protection on those circuits.\u003c\/p\u003e\n\u003ch4\u003eLow Frequency Versus High Frequency Inverter\u003c\/h4\u003e\n\u003cp\u003eThis inverter's transformer-based design is built for high surge loads, and AIMS says it suits power equipment and inductive loads. That design weighs 52.4 lbs here. A high frequency inverter is usually lighter and may suit loads with little startup surge.\u003c\/p\u003e\n\u003ch4\u003ePILF24W12V120V Versus a Modified Sine Inverter\u003c\/h4\u003e\n\u003cp\u003eA modified sine inverter makes a stepped waveform that some motors, chargers and electronics don't run well on. This inverter makes a pure sine wave close to utility power, so compressors and sensitive electronics can share it.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eLeave Headroom for Long Runs\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says not to run the output at 100% continuously. For loads that run longer than an hour, keep them at 50% or less, which is 1200W here, to prolong the inverter's life. If efficiency is a priority, AIMS suggests a larger inverter rather than leaning on surge.\u003c\/p\u003e\n\u003ch4\u003e1\/0 AWG Cable and a 300A Fuse\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the DC input at 12Vdc and 240Adc. Its chart suggests at least 1\/0 AWG cable with a 300A fuse for runs up to 5 feet and from 5 to 10 feet. Keep the battery within 10 feet, and torque the DC terminals within 12.5 to 20.5 Nm, with 17 Nm (12.6 lb-ft) suggested, since over-torquing can break the bolt.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need to start an air compressor on 12V\u003c\/li\u003e\n\u003cli\u003eYou want both hardwire and GFCI outlet options\u003c\/li\u003e\n\u003cli\u003eYour steady load stays near 1200W\u003c\/li\u003e\n\u003cli\u003eYour battery sits within 10 feet of the inverter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhich Way Can I Mount It?\u003c\/h4\u003e\n\u003cp\u003eMount it flat with the top side up, or on a wall with the DC terminals facing left or facing down. Never mount it upside down. AIMS calls for four 1\/4-20 steel bolts with flat and lock washers and nuts, on a surface that can hold at least twice the inverter's weight.\u003c\/p\u003e\n\u003ch4\u003eHow Much Clearance Does It Need?\u003c\/h4\u003e\n\u003cp\u003eAIMS recommends 12 inches of clearance around the inverter and at least 145 CFM of airflow, and says not to install it in a zero-clearance compartment. The case can reach 176°F (80°C), so keep it away from passersby.\u003c\/p\u003e\n\u003ch4\u003eWhy Is There No Power at the Outlets?\u003c\/h4\u003e\n\u003cp\u003eIf the LED is green with no buzzer and no AC output, the GFCI may be tripped, so reset it. If the output circuit breaker has tripped, reset the breaker.\u003c\/p\u003e\n\u003ch4\u003eCan I Extend the Remote Cable?\u003c\/h4\u003e\n\u003cp\u003eNo. AIMS says the LCD remote cable can be up to 60 feet long and shouldn't be extended. Never cut the cable while it's attached to a connected inverter, since a short can damage the remote circuit board inside.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Red DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Black DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x AC Terminal Block Cover With 2 Phillips Screws\u003c\/li\u003e\n\u003cli\u003e2 x Flange Nuts (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e4 x Phillips Screws (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eStartup Power for Compressors and Heavy Loads\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter brings a 7200W surge, hardwire and GFCI outputs and adjustable low battery protection to your 12V system. If you'd like a hand sizing cables, fuses or your battery bank, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003ePILF24W12V120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7200W for 20 seconds (300%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapable of Electric Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz (DIP switch selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;3%, max 10% under full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9-1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GFCI duplex receptacle (2 outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGFCI Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC, 60Hz, 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, AC terminal block (ground, L, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Terminal Wire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 20 AWG (10 to 8 AWG recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Terminal Ground Fault Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal output circuit breaker and GFCI output circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12Vdc \/ 240Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.0Vdc \/ 11.5Vdc \/ 12.5Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc \/ 10.5Vdc \/ 11.0Vdc \/ 12.0Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Voltage Recover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥13.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Alarm and Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥16.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Input Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdle Consumption, Search Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5W in Power Saver On mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Wake-Up Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 50W resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Search Pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery 3s or 30s (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, Up to 5 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG with 300A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, 5 to 10 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG with 300A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter to Battery Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 10 ft (larger cable beyond 10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5-20.5 Nm (9.25-15.19 lb-ft), 17 Nm (12.6 lb-ft) suggested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, current limit function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 110% to 125%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 125% to 150%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 150% to 300%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat sink ≥221°F (105°C), shuts down after 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Protections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow and high battery voltage alarm, fan lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, on circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eControls and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower On \/ Power Off \/ Power Saver Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-color LEDs (inverter mode, battery level, load level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional REMOTELF wired LCD remote (LCD RMT port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (18 m) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Remote Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery voltage, output voltage, output frequency, output load, fault code, battery capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional BT-AIMS-PRO dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (low battery set points, power saver search, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step intelligent fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 dB at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.9 x 13.5 x 7.2 in (480 x 344 x 184 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.4 lbs (23.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.2 x 17.5 x 10.6 in (590 x 445 x 270 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 lbs (26.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted or flat placement, any orientation except upside down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Bolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 1\/4-20 steel bolts with flat and lock washers and nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 in around the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Surface Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 176°F (80°C) in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG or larger copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed to UL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-pilf-man-071725.pdf\" title=\"AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-2400-watt-12-volt-low-frequency-pure-sine-power-inverter-manual.jpg\" alt=\"AIMS Power 2400 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662690287865,"sku":"PILF24W12V120V","price":814.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-2400-watt-12-volt-low-frequency-pure-sine-power-inverter-front-panel-with-battery-terminals-power-switch-fan-and-ac-terminal-block.jpg?v=1794358723","url":"https:\/\/outboundpower.com\/products\/aims-power-2400-watt-12-volt-low-frequency-pure-sine-power-inverter","provider":"Outbound Power","version":"1.0","type":"link"}