{"product_id":"aims-power-3000-watt-12-volt-split-phase-120-240vac-low-frequency-pure-sine-power-inverter","title":"AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/front-view-of-the-aims-power-3000-watt-split-phase-low-frequency-inverter-showing-battery-terminals-fan-and-120-240v-output-terminal.jpg\" alt=\"Front view of the AIMS Power 3000 Watt split phase low frequency inverter showing battery terminals, fan and 120\/240V output terminal\" width=\"864\" height=\"663\" style=\"display: block; width: 100%; max-width: 864px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter Delivers Both 120V and 240V From One 12V Battery Bank\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter turns 12V battery power into 120\/240VAC split phase pure sine power with a true neutral. It is rated 3000W continuous with a 9000W surge for up to 20 seconds, and it is ETL listed. Each hot leg gives 120Vac to neutral, and the two hot legs together give 240Vac.\u003c\/p\u003e\n\u003cp\u003eAIMS built it for homes, shops and backup power, including off-grid homes, mobile work vehicles and construction sites that need 240V for motors and pumps alongside everyday 120V loads. Wiring runs through a four-position hardwire terminal block, and a GFCI duplex receptacle covers plug-in loads. It is an inverter only, with no AC input, charger or transfer switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter Features\u003c\/h3\u003e\n\u003ch4\u003eTrue Split Phase Output\u003c\/h4\u003e\n\u003cp\u003eThe AC terminal block is marked ground, HOT1, HOT2 and N. HOT1 to N and HOT2 to N each measure 120Vac, and HOT1 to HOT2 measures 240Vac. AIMS's installation diagram shows the inverter feeding a sub-panel that serves both 120VAC and 240VAC outlets.\u003c\/p\u003e\n\u003ch4\u003e9000W Surge for High Inrush Loads\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the surge at 3x continuous power for up to 20 seconds, for equipment with high inrush current such as motors, compressors and refrigeration systems. AIMS lists the unit as capable of running a 3.0HP electric motor. Lighter overloads of 110% to 125% run for 15 minutes and 125% to 150% for 1 minute before shutdown.\u003c\/p\u003e\n\u003ch4\u003eHardwire Terminal With Its Own Breaker\u003c\/h4\u003e\n\u003cp\u003eA HOT1~HOT2 output circuit breaker protects the hardwire terminal, and the GFCI receptacle has its own GFCI output circuit breaker. The terminal accepts 8 to 20 AWG wire, and AIMS recommends 10 to 8 AWG. AIMS describes the hardwire connection as the way to use the inverter's full output capacity.\u003c\/p\u003e\n\u003ch4\u003eDSP Control Keeps Voltage Steady\u003c\/h4\u003e\n\u003cp\u003eDigital Signal Processing holds output within ±10% RMS as battery voltage changes. THD is typically under 3% and at most 10% under full linear load, so sensitive electronics, tools and appliances all get clean power. Output frequency is 50 or 60Hz by DIP switch.\u003c\/p\u003e\n\u003ch4\u003ePower Saver and Low Battery Settings\u003c\/h4\u003e\n\u003cp\u003eIn Power Saver Auto, idle draw falls below 2.5W until a resistive load over 50W appears. DIP switches set the low battery alarm and trip pair from 10.5\/10.0Vdc up to 12.5\/12.0Vdc, and the inverter restarts when the battery recovers to 13.0Vdc.\u003c\/p\u003e\n\u003ch4\u003eCoated Electronics and Smart Cooling\u003c\/h4\u003e\n\u003cp\u003eConformal coated circuit boards resist water, rust, dust and corrosion, and a 3-step fan adjusts to temperature and load at under 60 dB at 1 meter. The unit isn't splash proof, so install it in a dry, ventilated spot.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid homes.\u003c\/strong\u003e Feed a split phase sub-panel so 240V pumps and 120V lights and outlets share one battery bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShops.\u003c\/strong\u003e Run motors and pumps that require 240V, plus 120V tools on the same inverter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction sites and work vehicles.\u003c\/strong\u003e Bring split phase power to equipment where there's no grid connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackup power.\u003c\/strong\u003e Supply a dedicated set of 120V and 240V circuits from batteries, wired separately from utility power.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eSplit Phase Versus a 120V Single Phase Inverter\u003c\/h4\u003e\n\u003cp\u003eA single phase inverter gives you 120V only. This model gives you two 120V legs plus 240V between them, so one inverter can serve 240V motors and pumps along with standard 120V circuits.\u003c\/p\u003e\n\u003ch4\u003eLow Frequency Versus High Frequency Inverter\u003c\/h4\u003e\n\u003cp\u003eThe PILF's transformer-based design is what lets it hold 300% surge for 20 seconds, which AIMS says suits power equipment and inductive loads. It also weighs 57.3 lbs. A high frequency inverter is usually lighter and can suit loads with little startup surge.\u003c\/p\u003e\n\u003ch4\u003eHardwire Terminal Versus GFCI Outlets\u003c\/h4\u003e\n\u003cp\u003eThe GFCI duplex receptacle gives you 120V plug-in power. For 240V loads and for the inverter's full output, wire them to the hardwire terminal.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003ePlan the Load on Each Leg\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the inverter at 3000W continuous as a whole and doesn't publish a separate rating for each 120V leg. If you plan to put most of your load on one leg, check with the Outbound Power team first. AIMS's manual also says to keep loads that run longer than an hour at 50% or less, which is 1500W, to prolong the inverter's life.\u003c\/p\u003e\n\u003ch4\u003eDC Cabling for a 300A Input\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the DC input at 12Vdc and 300Adc. Its chart suggests at least 1\/0 AWG cable with a 300A fuse for runs up to 5 feet and from 5 to 10 feet. Keep the battery within 10 feet, ground the chassis with 8 AWG or larger copper wire and have a qualified installer such as a licensed electrician do the wiring.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need 240V and 120V from a 12V battery bank\u003c\/li\u003e\n\u003cli\u003eYou run 240V motors or pumps\u003c\/li\u003e\n\u003cli\u003eYou'll wire it into a split phase \u003cspan style=\"white-space: nowrap;\"\u003esub-panel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eYour steady load stays near 1500W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eHow Do I Get 240V From the Terminal?\u003c\/h4\u003e\n\u003cp\u003eConnect 240V loads between HOT1 and HOT2. Connect 120V circuits between either hot leg and N, and connect the ground to the ground position. AIMS warns not to loosen or touch the rear set screws on the terminal block.\u003c\/p\u003e\n\u003ch4\u003eIs the Terminal Output Ground Fault Protected?\u003c\/h4\u003e\n\u003cp\u003eNo. AIMS notes the AC terminal output is not ground fault protected, so plan any GFCI protection your circuits require and follow all applicable codes. The GFCI duplex receptacle has its own ground fault protection.\u003c\/p\u003e\n\u003ch4\u003eCan It Feed a Panel That's Also on the Grid?\u003c\/h4\u003e\n\u003cp\u003eNo. AIMS says the AC output must never be connected to utility power or a generator, because power fed back into the inverter will damage it instantly and may create a fire hazard.\u003c\/p\u003e\n\u003ch4\u003eWhich Remote Can I Use?\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says to use only the REMOTELF wired LCD remote in the LCD RMT port, on up to 60 feet of cable, and warns that other remotes will damage the inverter. AIMS also lists an optional BT-AIMS-PRO Bluetooth dongle.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Red DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Black DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x AC Terminal Block Cover With 2 Phillips Screws\u003c\/li\u003e\n\u003cli\u003e2 x Flange Nuts (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e4 x Phillips Screws (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e120V and 240V Power From Your 12V Bank\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter gives you split phase output, a 9000W surge and a hardwire terminal in a conformal coated, ETL listed case. If you'd like help planning your sub-panel, cables or battery bank, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003ePILF30W12V240VS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9000W for 20 seconds (300%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapable of Electric Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240Vac split phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOT1 to N\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOT2 to N\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOT1 to HOT2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz (DIP switch selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;3%, max 10% under full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9-1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GFCI duplex receptacle (2 outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGFCI Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC, 60Hz, 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, AC terminal block (ground, HOT1, HOT2, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Terminal Wire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 20 AWG (10 to 8 AWG recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Terminal Ground Fault Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHOT1~HOT2 output circuit breaker and GFCI output circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12Vdc \/ 300Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.0Vdc \/ 11.5Vdc \/ 12.5Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc \/ 10.5Vdc \/ 11.0Vdc \/ 12.0Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Voltage Recover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥13.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Alarm and Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥16.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Input Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdle Consumption, Search Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5W in Power Saver On mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Wake-Up Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 50W resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Search Pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery 3s or 30s (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, Up to 5 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG with 300A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, 5 to 10 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG with 300A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter to Battery Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 10 ft (larger cable beyond 10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5-20.5 Nm (9.25-15.19 lb-ft), 17 Nm (12.6 lb-ft) suggested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, current limit function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 110% to 125%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 125% to 150%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 150% to 300%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat sink ≥221°F (105°C), shuts down after 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Protections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow and high battery voltage alarm, fan lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, on circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eControls and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower On \/ Power Off \/ Power Saver Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-color LEDs (inverter mode, battery level, load level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional REMOTELF wired LCD remote (LCD RMT port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (18 m) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Remote Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery voltage, output voltage, output frequency, output load, fault code, battery capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional BT-AIMS-PRO dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (low battery set points, power saver search, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step intelligent fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 dB at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.9 x 13.5 x 7.2 in (480 x 344 x 184 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs (26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.2 x 17.5 x 10.6 in (590 x 445 x 270 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.6 lbs (28.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted or flat placement, any orientation except upside down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Bolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 1\/4-20 steel bolts with flat and lock washers and nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 in around the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Surface Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 176°F (80°C) in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG or larger copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-pilf-man-071725.pdf\" title=\"AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-3000-watt-12-volt-split-phase-120-240vac-low-frequency-pure-sine-power-inverter-manual.jpg\" alt=\"AIMS Power 3000 Watt 12 Volt Split Phase 120\/240VAC Low Frequency Pure Sine Power Inverter Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662696841465,"sku":"PILF30W12V240VS","price":880.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-3000-watt-12-volt-split-phase-120-240vac-low-frequency-pure-sine-power-inverter-front-panel-with-hot1-hot2-breaker-and-four-position-ac-terminal.jpg?v=1794358864","url":"https:\/\/outboundpower.com\/products\/aims-power-3000-watt-12-volt-split-phase-120-240vac-low-frequency-pure-sine-power-inverter","provider":"Outbound Power","version":"1.0","type":"link"}