{"product_id":"aims-power-600-watt-12-volt-low-frequency-pure-sine-power-inverter","title":"AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/end-view-of-the-aims-power-600-watt-low-frequency-pure-sine-inverter-showing-the-gfci-receptacle-lcd-remote-port-and-dip-switches.jpg\" alt=\"End view of the AIMS Power 600 Watt low frequency pure sine inverter showing the GFCI receptacle, LCD remote port and DIP switches\" width=\"547\" height=\"600\" style=\"display: block; width: 100%; max-width: 547px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter Gives Compact Work Truck Setups 1800W of Motor Starting Surge\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter turns 12V DC battery power into 120V AC pure sine power at 600W continuous and 5A. Its low frequency transformer design holds an 1800W surge for up to 20 seconds, which is 300% of its rating, so small motors, tools and appliances can start. AIMS lists it as capable of running a 0.6HP electric motor, and it is ETL listed to UL 458.\u003c\/p\u003e\n\u003cp\u003eAIMS built this PILF series model for work trucks and mobile setups, and it also fits remote job sites, food trucks, off-grid cabins and emergency backup systems. The case is 12.8 inches long and weighs 17 lbs, and power comes out of a GFCI duplex receptacle on the end panel. It is an inverter only, with no AC input or battery charger, so you'll charge your batteries with separate equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter Features\u003c\/h3\u003e\n\u003ch4\u003e300% Surge Gets Motors Up to Speed\u003c\/h4\u003e\n\u003cp\u003eThe 1800W surge lasts up to 20 seconds, which gives motors, compressors and tools time to start. Past the 600W rating, the inverter carries 110% to 125% load for 15 minutes, 125% to 150% for 1 minute and up to 300% for 20 seconds before it shuts down. A beeping alarm warns you first.\u003c\/p\u003e\n\u003ch4\u003ePure Sine Output With DSP Voltage Control\u003c\/h4\u003e\n\u003cp\u003eOutput is a 120VAC pure sine wave with a true neutral at 50 or 60Hz. A DSP (Digital Signal Processing) controller holds voltage regulation within ±10% RMS as your battery voltage rises and falls. AIMS lists THD as typically under 3%, with a 10% maximum under full linear load, so the output suits sensitive electronics as well as tools.\u003c\/p\u003e\n\u003ch4\u003eGFCI Outlets With Their Own Breaker\u003c\/h4\u003e\n\u003cp\u003eThe AC end panel has a GFCI duplex receptacle with two outlets and a GFCI output circuit breaker. This model has no hardwire terminal, so you plug loads straight into the inverter.\u003c\/p\u003e\n\u003ch4\u003ePower Saver Mode Cuts Idle Draw\u003c\/h4\u003e\n\u003cp\u003eSet the power switch to Power Saver Auto and the inverter pulses its output to look for a load, drawing less than 2.5W while it waits. A resistive load above 50W wakes it to full output. A DIP switch sets the search pulse to every 3 or 30 seconds.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Low Battery Cutoff\u003c\/h4\u003e\n\u003cp\u003eTwo DIP switches set the low battery alarm and trip pair to 10.5\/10.0Vdc, 11.0\/10.5Vdc, 11.5\/11.0Vdc or 12.5\/12.0Vdc. AIMS notes that solar users may want a higher cutoff to limit depth of discharge. After a low voltage shutdown, the inverter restarts on its own when the battery recovers to 13.0Vdc, as long as the switch is still on.\u003c\/p\u003e\n\u003ch4\u003eCoated Circuit Boards and a 3-Step Fan\u003c\/h4\u003e\n\u003cp\u003eAIMS conformal coats the circuit boards to resist water, rust, dust and corrosion, and a 3-step fan speeds up with heat sink temperature and load. The coating is not splash protection, though. AIMS says to keep the unit away from water and damp environments.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWork trucks.\u003c\/strong\u003e Run smaller corded tools, chargers and work lights from the truck's 12V battery bank, within the 600W rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFood trucks and mobile setups.\u003c\/strong\u003e Power small 120V appliances and electronics where there is no outlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid cabins.\u003c\/strong\u003e Add pure sine AC to a small 12V battery system for lights, fans and electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency backup.\u003c\/strong\u003e Keep a computer, router and lights going from a battery bank during an outage.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eLow Frequency PILF Versus a High Frequency Inverter\u003c\/h4\u003e\n\u003cp\u003eA low frequency inverter is built around a heavy transformer, which is where the PILF's 300% surge for 20 seconds comes from. AIMS says this design pays off with power equipment and other inductive loads that surge at startup. A high frequency inverter is usually lighter, which can suit loads with little startup surge.\u003c\/p\u003e\n\u003ch4\u003ePure Sine Versus a Modified Sine Inverter\u003c\/h4\u003e\n\u003cp\u003eA modified sine inverter puts out a stepped waveform that some electronics, chargers and motors don't run well on. The PILF6W12V120V puts out a pure sine wave with low distortion, much like utility power, so the same unit can run your tools and your electronics.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eSize for the Load You Run Longest\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says not to run the output at 100% continuously. For runs longer than an hour, keep the load at 50% or less, which is 300W on this model, to prolong the inverter's life. Surges also create heat and lower efficiency, so if efficiency matters, AIMS recommends a larger inverter.\u003c\/p\u003e\n\u003ch4\u003eBattery Cables and Fusing\u003c\/h4\u003e\n\u003cp\u003eAIMS rates this model's DC input at 12Vdc and 60Adc. For cable runs up to 5 feet, its chart suggests at least 6 AWG cable with an 80A fuse, and from 5 to 10 feet, 4 AWG with an 80A fuse. Keep the battery within 10 feet, ground the chassis with 8 AWG or larger copper wire, and confirm your cable and fuse ratings, since AIMS calls the chart a reference.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need pure sine 120V power from a 12V battery\u003c\/li\u003e\n\u003cli\u003eYour loads stay under 600W but surge at startup\u003c\/li\u003e\n\u003cli\u003eYou want plug-in GFCI outlets, not hardwiring\u003c\/li\u003e\n\u003cli\u003eSpace and weight are tight in your vehicle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eShould I Turn the Inverter On Before Plugging In Loads?\u003c\/h4\u003e\n\u003cp\u003eYes. The inverter runs a short self-check when it powers up, so wait a few seconds before switching loads on. Switch several loads on one at a time so their surges don't stack.\u003c\/p\u003e\n\u003ch4\u003eIs It Reverse Polarity Protected?\u003c\/h4\u003e\n\u003cp\u003eNo. Reversing the battery cables on the DC terminals causes permanent damage that AIMS does not cover, so check polarity before you connect.\u003c\/p\u003e\n\u003ch4\u003eWhich Remote Works With This Inverter?\u003c\/h4\u003e\n\u003cp\u003eAIMS's manual says to use only the REMOTELF wired LCD remote in the port labeled LCD RMT, and warns that any other remote will damage the inverter. The remote cable can be up to 60 feet long, and the display shows battery and output voltage, load and fault codes. AIMS also mentions an optional Bluetooth dongle for monitoring.\u003c\/p\u003e\n\u003ch4\u003eHow Can It Be Mounted?\u003c\/h4\u003e\n\u003cp\u003eMount it on a wall or set it flat in any orientation except upside down, using four 1\/4-20 steel bolts with flat and lock washers and nuts. Keep it out of battery compartments, leave about 12 inches of clearance for airflow, and place it where people can't touch the case, which can reach 176°F (80°C).\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Red DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Black DC Terminal Cover\u003c\/li\u003e\n\u003cli\u003e2 x Flange Nuts (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e4 x Phillips Screws (Installed on the DC Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eClean Pure Sine Power in a Compact Package\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter pairs an 1800W surge with GFCI outlets, DSP voltage control and coated circuit boards in a 17 lb case. If you'd like help sizing your loads, battery bank or cables, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003ePILF6W12V120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800W for 20 seconds (300%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapable of Electric Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120Vac single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz (DIP switch selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;3%, max 10% under full linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 88%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9-1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GFCI duplex receptacle (2 outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGFCI Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC, 60Hz, 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI output circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12Vdc \/ 60Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.0Vdc \/ 11.5Vdc \/ 12.5Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0Vdc \/ 10.5Vdc \/ 11.0Vdc \/ 12.0Vdc (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Battery Voltage Recover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥13.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Alarm and Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥16.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Input Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdle Consumption, Search Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5W in Power Saver On mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Wake-Up Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 50W resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Saver Search Pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery 3s or 30s (DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, Up to 5 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 AWG with 80A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested DC Cable, 5 to 10 ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AWG with 80A fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter to Battery Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 10 ft (larger cable beyond 10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5-20.5 Nm (9.25-15.19 lb-ft), 17 Nm (12.6 lb-ft) suggested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, current limit function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 110% to 125%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 125% to 150%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload 150% to 300%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts down after 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat sink ≥221°F (105°C), shuts down after 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Protections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow and high battery voltage alarm, fan lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, on circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eControls and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower On \/ Power Off \/ Power Saver Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-color LEDs (inverter mode, battery level, load level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional REMOTELF wired LCD remote (LCD RMT port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (18 m) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Remote Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery voltage, output voltage, output frequency, output load, fault code, battery capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (low battery set points, power saver search, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Fan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step intelligent fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFan Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 dB at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.8 x 7.1 x 5.4 in (325 x 181 x 136 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 lbs (7.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.1 x 9.1 x 8.3 in (435 x 230 x 210 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 lbs (8.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mounted or flat placement, any orientation except upside down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Bolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 1\/4-20 steel bolts with flat and lock washers and nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 in around the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Surface Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 176°F (80°C) in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG or larger copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed to UL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-pilf-man-071725.pdf\" title=\"AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-600-watt-12-volt-low-frequency-pure-sine-power-inverter-manual.jpg\" alt=\"AIMS Power 600 Watt 12 Volt Low Frequency Pure Sine Power Inverter Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662695301369,"sku":"PILF6W12V120V","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-600-watt-12-volt-low-frequency-pure-sine-power-inverter-ac-end-panel-with-gfci-duplex-outlet-and-output-breaker.jpg?v=1794358806","url":"https:\/\/outboundpower.com\/products\/aims-power-600-watt-12-volt-low-frequency-pure-sine-power-inverter","provider":"Outbound Power","version":"1.0","type":"link"}