{"product_id":"aims-power-badland-reserve-solar-kit-3960w-solar-4000w-48v-inverter-charger-20-4kwh-agm-battery","title":"AIMS Power Badland Reserve Solar Kit | 3960W Solar, 4000W 48V Inverter Charger, 20.4kWh AGM Battery","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/everything-in-the-aims-power-badland-reserve-solar-kit-laid-out-from-the-twelve-330-watt-panels-to-the-eight-agm-batteries-and-4000-watt-inverter-charger.jpg\" alt=\"Everything in the AIMS Power Badland Reserve Solar Kit laid out, from the twelve 330 watt panels to the eight AGM batteries and 4000 watt inverter charger\" width=\"1000\" height=\"1000\" style=\"display: block; width: 100%; max-width: 1000px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power Badland Reserve Solar Kit Stores Deep Backup Energy With 3960 Watts of Solar, Eight 200Ah AGM Batteries and a 4000 Watt 48V Split-Phase Inverter Charger\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power Badland Reserve Solar Kit is a complete 48 volt DC solar power system for sustained off-grid operation and long duration backup. Twelve 330 watt monocrystalline panels feed a combiner box, a quick disconnect switch and an 80 amp charge controller. They charge eight 12V 200Ah AGM batteries that form a 48V, 20.4 kWh bank, and a 4000 watt, 33 amp low frequency inverter charger with an integrated transfer switch delivers 120\/240V split-phase power.\u003c\/p\u003e\n\u003cp\u003eAIMS designed the Badland for do-it-yourself owners and installers who need dependable long term energy for off-grid cabins, remote properties, commercial applications and essential home backup. It works well where daily power demand is low to moderate but the system needs deep reserves and strong daytime solar production.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power Badland Reserve Solar Kit Features\u003c\/h3\u003e\n\u003ch4\u003e3960 Watts of Solar Production\u003c\/h4\u003e\n\u003cp\u003eTwelve 330 watt monocrystalline panels provide 3960 watts of charging for sustained off-grid operation and backup replenishment. Each panel measures 65.35 x 39.25 x 1.37 inches and weighs 40 lbs, and the full array needs about 240 square feet.\u003c\/p\u003e\n\u003ch4\u003eA 48V AGM Battery Bank With Deep Reserves\u003c\/h4\u003e\n\u003cp\u003eEight AGM12V200A 12V 200Ah valve regulated batteries make up the 48V, 20.4 kWh bank, giving you deep energy reserves for long runtime and extended backup. The battery label lists a cycle use charge voltage of 14.4 to 14.7V per battery.\u003c\/p\u003e\n\u003ch4\u003eA 4000 Watt Split-Phase Inverter Charger\u003c\/h4\u003e\n\u003cp\u003eThe 4000 watt, 33 amp, 48V DC inverter charger supplies 120\/240V AC for standard household devices and larger appliances that need 240V. Its integrated transfer switch handles the transition between solar, battery, grid and generator power. It comes with 8 foot cables and a battery temperature sensor, and its AC end has separate HOT1 and HOT2 output breakers.\u003c\/p\u003e\n\u003ch4\u003eAn Efficient 48 Volt Design\u003c\/h4\u003e\n\u003cp\u003eAIMS built the Badland at 48 volts DC to reduce current draw, minimize voltage loss, lower heat generation and support longer cable runs. That makes the system easier to scale and helps the inverter run efficiently on a larger off-grid setup.\u003c\/p\u003e\n\u003ch4\u003eA Combiner Box, Disconnect and Matched Fuses\u003c\/h4\u003e\n\u003cp\u003eThe PV combiner box has six PV input pairs, comes with connectors and simplifies the array wiring. The quick disconnect switch, marked DC Disconnect PV Array, lets you isolate the solar array. The kit includes a 100A battery to inverter fuse and an 80A charge controller to battery fuse, and the 80 amp controller comes with 8 foot cables.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCabins and remote outposts.\u003c\/strong\u003e Power off-grid cabins, tiny homes, hunting cabins and remote outposts with low to moderate daily demand.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEssential home backup.\u003c\/strong\u003e Keep 120V and 240V critical loads such as well pumps, refrigeration and gas furnace blowers running during outages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFarms and ranches.\u003c\/strong\u003e Supply water well pumping, livestock barns and automated gates on remote land.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWork sites and workshops.\u003c\/strong\u003e Run off-grid workshops with moderate power tool use, or provide basecamp power for construction sites and jobsite trailers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeasonal and waterfront property.\u003c\/strong\u003e Support seasonal off-grid properties, fixed marine docks and boat houses where strong daytime solar keeps the AGM bank charged.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eBadland AGM Batteries Versus Lithium Batteries\u003c\/h4\u003e\n\u003cp\u003eLithium batteries are another common way to store solar energy. The Badland uses AGM batteries instead, and AIMS pairs them with a 3960 watt array because AGM batteries recharge more slowly and benefit from high daytime solar production.\u003c\/p\u003e\n\u003ch4\u003e48V System Versus a 12V System\u003c\/h4\u003e\n\u003cp\u003eA 12V system draws much more current for the same power, with more voltage loss, more heat and shorter practical cable runs. The Badland's 48 volt design reduces current draw and wiring strain on a large system.\u003c\/p\u003e\n\u003ch4\u003eComplete Kit Versus Sourcing Each Part\u003c\/h4\u003e\n\u003cp\u003eBuilding a system this size from separate parts means matching panels, a combiner box, a disconnect, a controller, eight batteries, an inverter charger, fuses and wire yourself. The Badland's components are matched for compatibility, which simplifies planning and installation.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eSize Your Loads and Plan for Recharge\u003c\/h4\u003e\n\u003cp\u003eKeep the total of everything you run at the same time within the inverter charger's 4000 watt rating. The 20.4 kWh AGM bank gives you deep reserves, but AGM batteries recharge more slowly, so plan on strong daytime sun or grid and generator charging to refill the bank.\u003c\/p\u003e\n\u003ch4\u003ePlan for Space and Weight\u003c\/h4\u003e\n\u003cp\u003eThe twelve panels need about 240 square feet, and the full kit weighs about 500 lbs. Set aside room for eight batteries, and plan where the combiner box, disconnect, controller and inverter charger will mount before you route the 100 feet and 20 feet of PV wire.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need deep backup reserves\u003c\/li\u003e\n\u003cli\u003eYour daily demand is low to moderate\u003c\/li\u003e\n\u003cli\u003eYou want 120V and 240V power\u003c\/li\u003e\n\u003cli\u003eYou prefer an AGM battery bank\u003c\/li\u003e\n\u003cli\u003eYou have about 240 square feet for panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat Can the Badland Power?\u003c\/h4\u003e\n\u003cp\u003eAIMS lists well pumps, refrigeration, gas furnace blowers, livestock barns, automated gates and moderate power tool use among its uses. What you can run at once, and for how long, depends on your total load and the battery's charge.\u003c\/p\u003e\n\u003ch4\u003eWhat Batteries Come With the Kit?\u003c\/h4\u003e\n\u003cp\u003eYou get eight 12V 200Ah AGM batteries that make up the kit's 48V, 20.4 kWh bank.\u003c\/p\u003e\n\u003ch4\u003eCan the Badland Use Grid or Generator Power?\u003c\/h4\u003e\n\u003cp\u003eYes. The integrated transfer switch handles the transition between solar, battery, grid and generator power sources.\u003c\/p\u003e\n\u003ch4\u003eWhich Fuses Are Included?\u003c\/h4\u003e\n\u003cp\u003eThe kit includes a 100A battery to inverter fuse and an 80A charge controller to battery fuse.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12 x 330 Watt Solar Panel\u003c\/li\u003e\n\u003cli\u003e1 x Combiner Box\u003c\/li\u003e\n\u003cli\u003e1 x 80 Amp Charge Controller With 8ft Cables\u003c\/li\u003e\n\u003cli\u003e8 x AGM 12V 200Ah Battery\u003c\/li\u003e\n\u003cli\u003e1 x Quick Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e1 x Battery to Inverter Fuse 100A\u003c\/li\u003e\n\u003cli\u003e1 x Charge Controller to Battery Fuse 80A\u003c\/li\u003e\n\u003cli\u003e1 x Set of PV Wires 100Ft and 20Ft\u003c\/li\u003e\n\u003cli\u003e1 x 4000 Watt 33 Amp 48V DC 120\/240V AC Inverter Charger With Transfer Switch and 8ft Cables\u003c\/li\u003e\n\u003cli\u003e1 x Battery Temp Sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eDeep Reserves for Long Duration Backup\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power Badland Reserve Solar Kit pairs 3960 watts of solar with a 48V AGM battery bank and a 4000 watt split-phase inverter charger, with the combiner box, disconnect, fuses and temperature sensor already matched. If you'd like help sizing your loads or planning the install, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power Badland Reserve Solar Kit | 3960W Solar, 4000W 48V Inverter Charger, 20.4kWh AGM Battery Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eKit Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eSolar Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e12 x 330 Watt monocrystalline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 80 Amp, with 8ft cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 x AGM 12V 200Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Bank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V, 20.4 kWh total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 4000 Watt, 33 Amp, 48V DC, 120\/240V AC, transfer switch, 8ft cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Temp Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuick Disconnect Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery to Inverter Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Controller to Battery Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100Ft and 20Ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Space Needed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbout 240 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSolar Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePV330MONO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonocrystalline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Solar Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3960 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.35 x 39.25 x 1.37 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLF (low frequency) inverter charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmp Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC split phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated, between solar, battery, grid and generator power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardwire terminal block, HOT1 and HOT2 output breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Temp Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAGM12V200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAGM, valve regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBank Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBank Energy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle Use Charge Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.4-14.7V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Use Charge Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.62-13.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial Charge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCharge Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCables and Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePV combiner box, 6 PV input pairs, connectors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuick Disconnect Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC disconnect for PV array, rotary off and on handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisconnect Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66NW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100Ft and 20Ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery to Inverter Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Controller to Battery Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662677541113,"sku":"RCBADLAND","price":10025.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-badland-reserve-solar-kit-contents-with-twelve-solar-panels-combiner-box-charge-controller-disconnect-switch-eight-agm-batteries-inverter-charger-cables-fuse-and-tempera.jpg?v=1794358585","url":"https:\/\/outboundpower.com\/products\/aims-power-badland-reserve-solar-kit-3960w-solar-4000w-48v-inverter-charger-20-4kwh-agm-battery","provider":"Outbound Power","version":"1.0","type":"link"}