{"product_id":"aims-power-boundary-sentinel-solar-kit-720w-solar-4000w-inverter-charger-7-68kwh-agm-battery","title":"AIMS Power Boundary Sentinel Solar Kit | 720W Solar, 4000W Inverter Charger, 7.68kWh AGM Battery","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/every-component-of-the-aims-power-boundary-sentinel-solar-kit-laid-out-from-the-six-120-watt-panels-to-the-three-agm-batteries-and-split-phase-inverter-charger.jpg\" alt=\"Every component of the AIMS Power Boundary Sentinel Solar Kit laid out, from the six 120 watt panels to the three AGM batteries and split-phase inverter charger\" width=\"1000\" height=\"1000\" style=\"display: block; width: 100%; max-width: 1000px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power Boundary Sentinel Solar Kit Runs Larger Appliances, Tools and Pumps With 720 Watts of Solar, 7.68 kWh of AGM Storage and a 4000 Watt Split-Phase Inverter Charger\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power Boundary Sentinel Solar Kit is a complete off-grid and backup solar power system from AIMS's Sentinel Class. It includes six 120 watt solar panels, a combiner box, a quick DC disconnect, a 60 amp charge controller with 8 foot cables, three deep cycle AGM 12V 200 amp batteries for 7.68 kWh of storage, and a 4000 watt low frequency inverter charger with 120\/240V output, 240V input and 6 foot cables. Fuses, an inline solar fuse, PV wire and a battery temperature sensor complete the kit.\u003c\/p\u003e\n\u003cp\u003eAIMS built the Boundary for do-it-yourself owners and installers who need dependable power for homes, cabins, workshops and remote sites. It suits people who move between solar battery power and utility or generator backup, and anyone who wants split-phase power for larger appliances, tools and pumps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power Boundary Sentinel Solar Kit Features\u003c\/h3\u003e\n\u003ch4\u003e4000 Watts of 120\/240V Split-Phase Power\u003c\/h4\u003e\n\u003cp\u003eThe 4000 watt inverter charger outputs up to 33 amps of 120\/240V power for common appliances, tools, pumps and larger electrical loads. It runs from a 12V battery bank, accepts 240V AC input and comes with 6 foot cables. AIMS's split-phase photo shows hardwire AC input and output terminals with separate HOT1 and HOT2 output breakers.\u003c\/p\u003e\n\u003ch4\u003e7.68 kWh of Deep Cycle AGM Storage\u003c\/h4\u003e\n\u003cp\u003eThree AIMS AGM12V200A 12V 200Ah batteries make up the 7.68 kWh bank for longer runtime during outages or off-grid use. The battery label identifies them as valve regulated, with a cycle use charge of 14.4 to 14.7V and an initial charging current of less than 60A.\u003c\/p\u003e\n\u003ch4\u003eSix Panels That Are Easier to Handle\u003c\/h4\u003e\n\u003cp\u003eThe 720 watt array uses six 120 watt panels instead of fewer large ones. AIMS chose this layout for a more manageable panel size and more flexibility around roof obstacles, limited mounting space or unusual layouts. The array needs about 44 square feet.\u003c\/p\u003e\n\u003ch4\u003eA 60 Amp MPPT Charge Controller\u003c\/h4\u003e\n\u003cp\u003eThe 60 amp MPPT charge controller comes with 8 foot cables. Its screen shows solar input voltage, wattage and amperage, battery voltage, battery capacity and a daily kWh total, and alarm, charge and load lights sit beside it.\u003c\/p\u003e\n\u003ch4\u003eCombiner Box and Quick DC Disconnect\u003c\/h4\u003e\n\u003cp\u003eThe PV combiner box gathers the panel wiring in one place and comes with connectors. The quick DC disconnect, marked DC Disconnect PV Array, lets you isolate the array for service. PV wire for the controller, disconnect and combiner box is included in 100 foot and 20 foot lengths.\u003c\/p\u003e\n\u003ch4\u003eFlexible Power Management\u003c\/h4\u003e\n\u003cp\u003eAIMS designed the Boundary for users who switch between solar battery power and utility or generator backup. The included battery temperature sensor, a 500A battery to inverter fuse, an 80A charge controller to battery fuse and an inline solar fuse round out the system.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRVs and boats.\u003c\/strong\u003e Support extended boondocking in medium-sized RVs, fifth wheels and travel trailers, or power liveaboard sailboats and cruiser catamarans.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHome backup.\u003c\/strong\u003e Keep high-surge critical loads such as full-size refrigerators, sump pumps, well pumps and medical equipment running during outages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabins and farms.\u003c\/strong\u003e Power mid-sized off-grid cabins, tiny homes and hunting lodges, or supply well water pumps, livestock feeding automation and barn power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWork and commercial rigs.\u003c\/strong\u003e Run food trucks, coffee rigs and espresso vans, heavy-duty mobile workshops and service rigs, or jobsite stations for corded tools and battery charging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvents and emergencies.\u003c\/strong\u003e Supply pop-up event stages, festival lighting and vendor stalls, disaster relief command centers, radio repeaters and field research labs.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eSix Smaller Panels Versus Fewer Large Panels\u003c\/h4\u003e\n\u003cp\u003eLarger panels are harder to handle and to fit around roof obstacles. The Boundary's six 120 watt panels are easier to handle and give you more ways to arrange the array in tight or unusual spaces.\u003c\/p\u003e\n\u003ch4\u003eSplit-Phase Inverter Charger Versus a 120V Only Inverter\u003c\/h4\u003e\n\u003cp\u003eA 120V only inverter can't power equipment that needs 240V. The Boundary's inverter charger provides 120\/240V output for larger electrical loads as well as standard appliances.\u003c\/p\u003e\n\u003ch4\u003eComplete Kit Versus Sourcing Each Part\u003c\/h4\u003e\n\u003cp\u003ePutting together panels, a combiner box, a disconnect, a controller, batteries, an inverter charger, fuses and wire on your own takes careful matching. AIMS selected the Boundary's components to work together, which simplifies installation.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eSize Your Loads\u003c\/h4\u003e\n\u003cp\u003eKeep everything you run at once within the inverter charger's 4000 watt rating and its 33 amp output. The 7.68 kWh bank sets how much energy is stored, and AIMS notes that daytime solar replenishes the AGM bank between high-surge, intermittent loads.\u003c\/p\u003e\n\u003ch4\u003ePlan the Array and Mounting\u003c\/h4\u003e\n\u003cp\u003eAllow about 44 square feet for the six panels. Panel mounting brackets appear in AIMS's kit graphic but aren't on its component list, so confirm your mounting hardware before you install.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need 120\/240V power for appliances, tools or pumps\u003c\/li\u003e\n\u003cli\u003eYou want a 12V AGM battery bank\u003c\/li\u003e\n\u003cli\u003eYou'd like smaller panels that are easier to place\u003c\/li\u003e\n\u003cli\u003eYou switch between solar, utility and generator power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eHow Much Current Can the Inverter Supply?\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the 4000 watt inverter charger for up to 33 amps of 120\/240V output.\u003c\/p\u003e\n\u003ch4\u003eWhy Does the Kit Use Six 120 Watt Panels?\u003c\/h4\u003e\n\u003cp\u003eSmaller panels are easier to handle and give you more flexibility when designing around roof obstacles, limited mounting space or unusual layouts.\u003c\/p\u003e\n\u003ch4\u003eWhich Fuses Come With the Kit?\u003c\/h4\u003e\n\u003cp\u003eThe kit includes a 500A battery to inverter fuse, an 80A charge controller to battery fuse and an inline solar fuse.\u003c\/p\u003e\n\u003ch4\u003eHow Much Space Do the Panels Need?\u003c\/h4\u003e\n\u003cp\u003eAIMS recommends about 44 square feet for the six panels.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6 x 120 Watt Solar Panel\u003c\/li\u003e\n\u003cli\u003e1 x 60 Amp Charge Controller With 8FT Cables\u003c\/li\u003e\n\u003cli\u003e3 x Deep Cycle AGM 12V 200 Amp Battery (AGM12V200A)\u003c\/li\u003e\n\u003cli\u003e1 x Battery to Inverter Fuse 500A\u003c\/li\u003e\n\u003cli\u003e1 x Inline Solar Fuse\u003c\/li\u003e\n\u003cli\u003e1 x Charge Controller to Battery Fuse 80A\u003c\/li\u003e\n\u003cli\u003e1 x Set of PV Wires 100FT and 20FT\u003c\/li\u003e\n\u003cli\u003e1 x 4000 Watt Inverter Charger 120\/240V AC Output 240V AC Input 12V With 6FT Cables\u003c\/li\u003e\n\u003cli\u003e1 x Quick DC Disconnect\u003c\/li\u003e\n\u003cli\u003e1 x Combiner Box\u003c\/li\u003e\n\u003cli\u003e1 x Battery Temp Sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eSplit-Phase Power for Homes, Cabins and Rigs\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power Boundary Sentinel Solar Kit brings together 720 watts of easy-to-place solar, a 60 amp MPPT controller, 7.68 kWh of AGM storage and a 4000 watt split-phase inverter charger for homes, cabins, rigs and remote sites. If you'd like help sizing your loads or planning the install, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power Boundary Sentinel Solar Kit | 720W Solar, 4000W Inverter Charger, 7.68kWh AGM Battery Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eKit Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eSolar Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e6 x 120 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 60 Amp, with 8FT cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x deep cycle AGM 12V 200 amp, 7.68 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery to Inverter Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInline Solar Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Controller to Battery Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100FT and 20FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 4000 Watt, 120\/240V AC output, 240V AC input, 12V, with 6FT cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuick DC Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Temp Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Space Needed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbout 44 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSolar Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Solar Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow frequency inverter charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V split-phase, up to 33 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardwire terminal block, AC input HOT1 and HOT2, AC output HOT1, HOT2 and N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHOT1 output protect, HOT2 output protect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAGM12V200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeep cycle AGM, valve regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage and Capacity (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V 200Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBank Energy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.68 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Voltage, Cycle Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.4-14.7V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Voltage, Standby Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.62-13.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial Charge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCharge Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolar input voltage, solar input wattage, battery voltage, solar input amperage, battery capacity, daily kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator Lights\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, charge, load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCables and Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePV combiner box, connectors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 7\/8 x 17 3\/8 x 7 5\/8 in (14 5\/8 in overall width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombiner Box Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuick DC Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC disconnect PV array, marked IP66NW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wires\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100FT and 20FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInline Solar Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery to Inverter Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Controller to Battery Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Temp Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662694580473,"sku":"SCBOUNDARY","price":5625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-boundary-sentinel-solar-kit-contents-with-six-solar-panels-charge-controller-combiner-box-disconnect-switch-three-agm-batteries-inverter-charger-pv-wires-and-fuses.jpg?v=1794358791","url":"https:\/\/outboundpower.com\/products\/aims-power-boundary-sentinel-solar-kit-720w-solar-4000w-inverter-charger-7-68kwh-agm-battery","provider":"Outbound Power","version":"1.0","type":"link"}