{"product_id":"aims-power-pihy9600-hybrid-inverter-solar-kit-9-6kw-120-240v-inverter-30-x-330w-mono-panels-9900w-solar","title":"AIMS Power PIHY9600 Hybrid Inverter Solar Kit | 9.6kW 120\/240V Inverter, 30 x 330W Mono Panels, 9900W Solar","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-pihy9600-kit-contents-laid-out-a-9.6kw-hybrid-inverter-with-9900w-of-solar-panels-and-pv-wire.jpg\" alt=\"AIMS Power PIHY9600 kit contents laid out, a 9.6kW hybrid inverter with 9900W of solar panels and PV wire\" width=\"1000\" height=\"1000\" style=\"display: block; width: 100%; max-width: 1000px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe AIMS Power PIHY9600 Hybrid Inverter Solar Kit Gives Your Home 9900 Watts of Solar and 9.6kW of Split Phase Power\u003c\/h2\u003e\n\u003cp\u003eThe AIMS Power PIHY9600 Hybrid Inverter Solar Kit pairs AIMS's 9.6kW PIHY9600 hybrid inverter charger with thirty 330 watt monocrystalline solar panels, for 9900 watts of solar in one order. Two 100 foot PV wire sets with MC4 connectors carry power from the array to the inverter.\u003c\/p\u003e\n\u003cp\u003eIt's meant for homeowners and solar installers planning a larger grid-tied system that can also take a battery bank and a generator. The inverter connects to 120\/240V split phase service (AIMS also rates it for 208V, not three phase), shares load with the grid and keeps an isolated backup output for the circuits you define. The kit has no batteries, so you choose a lithium or lead battery bank that suits the inverter's high voltage battery port.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eAIMS Power PIHY9600 Hybrid Inverter Solar Kit Features\u003c\/h3\u003e\n\u003ch4\u003eThirty 330W Mono Panels for 9900 Watts\u003c\/h4\u003e\n\u003cp\u003eEvery panel is rated 330 watts at an optimum power voltage of 33.9 volts and an optimum operating current of 9.73 amps, with an open circuit voltage of 41.5 volts and a short circuit current of 10.22 amps. Sixty monocrystalline cells reach a module efficiency of 19.78 percent. The panels use 3.2 mm front glass, carry a 6000Pa surface load rating and measure 65.35 x 39.37 x 1.4 inches at 39.7 lbs each.\u003c\/p\u003e\n\u003ch4\u003eDirect 3 String PV Input Rated to 15 kW\u003c\/h4\u003e\n\u003cp\u003eThe PV side accepts up to 15 kW of solar input. Maximum PV voltage is 660 volts, the MPPT range is 80 to 550 volts and startup begins at 100 volts. Maximum input current is 15.5 amps x 3, with a maximum short circuit current of 26 amps x 3.\u003c\/p\u003e\n\u003ch4\u003e9.6 kVA of Grid Tie Output\u003c\/h4\u003e\n\u003cp\u003eThe grid connection is rated 9.6 kVA continuous, with a peak of 11.5 kVA at 240 volts or 10.3 kVA at 208 volts for 10 minutes. The power factor is 0.99 and adjustable, current THD stays under 3 percent, and you can set charge and load times to match your local utility's recommendations. Load sharing is built in.\u003c\/p\u003e\n\u003ch4\u003eBackup and Generator Power on One Output\u003c\/h4\u003e\n\u003cp\u003eThe isolated emergency backup output runs the loads you define at 240 volts line to line and 120 volts line to neutral, 60 Hz, with under 3 percent voltage THD. It's rated 9.6 kVA continuous and switches over in under 10 milliseconds. A generator input accepts 240VAC for backup.\u003c\/p\u003e\n\u003ch4\u003eA 230 Volt Battery Port for Lithium or Lead\u003c\/h4\u003e\n\u003cp\u003eThe battery port is designed around a 230 volt nominal bank, with an 80 to 495 volt range and up to 50 amps of charge and discharge current. You can customize the DC input voltage for battery types including lithium and lead.\u003c\/p\u003e\n\u003ch4\u003eEfficient, Quiet and Built for Outdoors\u003c\/h4\u003e\n\u003cp\u003eAIMS rates the inverter at 97 percent CEC efficiency and 97.6 percent maximum efficiency, with 98.1 percent PV to battery and 96.8 percent battery to AC. Natural convection cooling keeps noise under 25 dB, and the IP65 and NEMA4X enclosure is rated for outdoor installation from -25 to 60°C.\u003c\/p\u003e\n\u003ch4\u003eProtection, Listings and Communication\u003c\/h4\u003e\n\u003cp\u003eBuilt-in protection covers reverse polarity on the PV and battery inputs, over current and over voltage, anti-islanding, AC short circuits, residual current, ground faults, insulation resistance, PV arcs and rapid shutdown, with SunSpec communication to rapid shutdown devices. Certifications and approvals include UL 1741 SA, CSA 22.2 No. 107-01, UL 1998, Rule 21, HECO Rule 14 and CEC. A full color display, RS485, CAN and Wi-Fi handle setup and monitoring, and up to 6 units can be stacked.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLarger grid-tied homes.\u003c\/strong\u003e Put 9900 watts of solar to work on your household loads and share load with the grid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCritical circuit backup.\u003c\/strong\u003e Wire the circuits you choose to the emergency backup output and add a battery bank for power during outages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator backup.\u003c\/strong\u003e Connect a 240VAC generator to the generator input for another backup source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUtility-guided charging.\u003c\/strong\u003e Program charge and load times to follow your utility's recommendations.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003ePIHY9600 Kit Versus a Grid-Tie Only Inverter\u003c\/h4\u003e\n\u003cp\u003eA grid-tie only inverter feeds your home and the grid but has no battery port or backup output. The PIHY9600 adds both, plus a generator input, so the same solar array can support battery backup.\u003c\/p\u003e\n\u003ch4\u003eHybrid Inverter Versus an Off-Grid Inverter\u003c\/h4\u003e\n\u003cp\u003eAn off-grid inverter works only from batteries with no utility connection. The PIHY9600 is built to tie to the grid, with anti-islanding protection and utility approvals, while it also manages solar, batteries and a generator.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eLay Out the Array and Mounting\u003c\/h4\u003e\n\u003cp\u003eThere's no set string layout in the kit, so have your installer arrange the thirty panels so each string stays within the 660 volt maximum PV voltage and the 80 to 550 volt MPPT range. Each panel has an open circuit voltage of 41.5 volts. Racking isn't on the component list, so plan mounting separately. The inverter mounts on a wall bracket, measures about 23 3\/4 x 15 3\/4 x 9 1\/4 inches and weighs about 55 lbs. Leave the grid and panel connections to a qualified electrician.\u003c\/p\u003e\n\u003ch4\u003eChoose a Battery Bank\u003c\/h4\u003e\n\u003cp\u003eBatteries aren't included. For backup power, choose a lithium or lead bank that suits the 230 volt nominal battery port and its 80 to 495 volt range, and keep backup loads within 9.6 kVA continuous.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou have 120\/240V split phase grid service\u003c\/li\u003e\n\u003cli\u003eYou want 9900 watts of solar with one inverter\u003c\/li\u003e\n\u003cli\u003eYou plan to add a high voltage battery bank\u003c\/li\u003e\n\u003cli\u003eYou want a backup output for chosen circuits\u003c\/li\u003e\n\u003cli\u003eYou have space for thirty 330W panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eAre Batteries Part of This Kit?\u003c\/h4\u003e\n\u003cp\u003eNo. You get the PIHY9600 hybrid inverter charger, thirty 330 watt panels and two 100 foot PV wire sets. The battery port accepts lithium or lead banks between 80 and 495 volts.\u003c\/p\u003e\n\u003ch4\u003eCan the Inverter Be Mounted Outside?\u003c\/h4\u003e\n\u003cp\u003eYes. The IP65 and NEMA4X enclosure is rated for outdoor installation, and the inverter runs without derating at altitudes under 4000 m (13123 ft).\u003c\/p\u003e\n\u003ch4\u003eHow Fast Does the Backup Output Switch Over?\u003c\/h4\u003e\n\u003cp\u003eThe switching time is under 10 milliseconds.\u003c\/p\u003e\n\u003ch4\u003eWhat Warranty Does AIMS Give?\u003c\/h4\u003e\n\u003cp\u003eAIMS lists a 10 year warranty on the hybrid inverter, and the panels carry a power output warranty of 91.2 percent at 12 years and 80.6 percent at 25 years.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Hybrid Inverter Charger 9.6kW (PIHY9600)\u003c\/li\u003e\n\u003cli\u003e30 x 330 Watt Monocrystalline Solar Panel\u003c\/li\u003e\n\u003cli\u003e2 x 100FT PV Wire Set, MC4 Male to Bare End and MC4 Female to Bare End\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eA Large Solar Array With Room to Grow\u003c\/h3\u003e\n\u003cp\u003eThe AIMS Power PIHY9600 Hybrid Inverter Solar Kit brings together 9900 watts of solar, a 9.6kW split phase hybrid inverter and the PV wire to connect them, with a battery port and generator input ready when you need them. If you'd like help sizing strings or a battery bank, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eAIMS Power PIHY9600 Hybrid Inverter Solar Kit | 9.6kW 120\/240V Inverter, 30 x 330W Mono Panels, 9900W Solar Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eKit Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eHybrid Inverter Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e1 x 9.6kW (PIHY9600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolar Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 x 330W monocrystalline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Solar Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9900W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 sets, 100FT, MC4 male to bare end and MC4 female to bare end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSolar Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptimum Power Voltage (Vmp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.9V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptimum Operating Current (Imp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.73A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Voltage (Voc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current (Isc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.22A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolar Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158.75 x 158.75 mm mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 (6 x 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCell Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.47%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.78%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFill Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70-76%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient of Isc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.048%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient of Voc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.29%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient of Pm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.37%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Glass Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface Maximum Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Hail Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45mm at 30.7m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBypass Diode Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Test Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM1.5, 1000W\/m2, 25 +\/-2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.35 x 39.37 x 1.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (Each)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.7 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter PV Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax PV Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e660V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPPT Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.5A x 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Short Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26A x 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect 3 string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Battery Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80-495V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLithium or lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Charge\/Discharge Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 \/ 10.3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Charge\/Discharge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter AC Grid\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Continuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Peak Power (10 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 kVA at 240V, 10.3 kVA at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Continuous Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A at 240V, 46.5A at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Peak Current (10 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.9A at 240V, 49.5A at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Grid Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e211-264V at 240V, 183-229V at 208V (split phase, not 3 phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Grid Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent THD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter AC Backup and Generator\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Continuous Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Continuous Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A at 240V, 46.5A at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Peak Current (10 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.9A at 240V, 49.5A at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Peak Power (10 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 kVA at 240V, 10.3 kVA at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal AC Voltage L-L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V or 208V (not 3 phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal AC Voltage L-N\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal AC Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage THD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC for backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmergency Backup Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated, for defined loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCEC Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV to Battery Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery to AC Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Reverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Reverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver Current\/Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnti-Islanding Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Short Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Fault Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Arc Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRapid Shutdown\/Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, NEMA4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter General\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4000 m (\u0026lt;13123 ft) without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Emission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication With RSD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSunSpec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay and Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull color display, RS485, CAN, Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Sharing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStackable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 3\/4 x 15 3\/4 x 9 1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications and Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1741 SA, CSA 22.2 No. 107-01, UL 1998, Rule 21, HECO Rule 14, CEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHybrid Inverter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolar Panel Power Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91.2% at 12 years, 80.6% at 25 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIMS Power","offers":[{"title":"Default Title","offer_id":67662613774585,"sku":"KIT-HY96SOL","price":14849.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/aims-power-pihy9600-hybrid-inverter-solar-kit-graphic-with-the-9.6kw-hybrid-inverter-thirty-330w-panels-and-pv-wire-sets.jpg?v=1794358260","url":"https:\/\/outboundpower.com\/products\/aims-power-pihy9600-hybrid-inverter-solar-kit-9-6kw-120-240v-inverter-30-x-330w-mono-panels-9900w-solar","provider":"Outbound Power","version":"1.0","type":"link"}