{"product_id":"bluetti-epanel-smart-distribution-panel-for-rv5","title":"BLUETTI Epanel Smart Distribution Panel for RV5","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/bluetti-epanel-smart-ac-and-dc-distribution-panel-for-the-rv5-system.jpg\" alt=\"BLUETTI Epanel smart AC and DC distribution panel for the RV5 system\" width=\"616\" height=\"516\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe BLUETTI Epanel Smart Distribution Panel Puts 8 AC and 20 DC Circuits in One Box You Can Monitor and Switch From the App\u003c\/h2\u003e\n\u003cp\u003eThe BLUETTI Epanel Smart Distribution Panel combines AC and DC power distribution with communication modules in a single unit. It has 8 AC output circuits and 20 DC output circuits, and 4 AC and 6 DC smart circuits can be monitored and switched in real time from the BLUETTI app or the Epad.\u003c\/p\u003e\n\u003cp\u003eBLUETTI designed it for RVs, boats, off-grid buildings and other compact power systems, and it links to the BLUETTI RV5 and Epad through its communication ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eBLUETTI Epanel Smart Distribution Panel Features\u003c\/h3\u003e\n\u003ch4\u003eSmart Circuits With Power Metering\u003c\/h4\u003e\n\u003cp\u003eFour AC outlets and six DC outlets have internal switches and power metering, so you can see what each one draws and turn it on or off remotely. All smart circuits turn on automatically when the Epanel powers on.\u003c\/p\u003e\n\u003ch4\u003e120V or 240V Split-Phase AC Input\u003c\/h4\u003e\n\u003cp\u003eMAIN1 and MAIN2 breakers allow dual AC input up to 50A. With the copper busbar in place, the Epanel takes 120V single-phase input. Remove the busbar for 240V split-phase input.\u003c\/p\u003e\n\u003ch4\u003e20 Fused DC Circuits\u003c\/h4\u003e\n\u003cp\u003eThe DC side accepts 10V to 30V at up to 100A through a bolt-on main fuse, and each of its 20 outputs has its own blade fuse rated for up to 20A per circuit. A red indicator lights if a fuse is missing or blown while DC power is on.\u003c\/p\u003e\n\u003ch4\u003eBuilt-In Overcurrent Alerts\u003c\/h4\u003e\n\u003cp\u003eSmart DC circuits warn at 20A and shut off at 25A, and smart AC circuits warn at 30A and shut off at 35A. An input overvoltage warning also appears in the app or on the Epad.\u003c\/p\u003e\n\u003ch4\u003eRJ45 Links to the RV5 and Epad\u003c\/h4\u003e\n\u003cp\u003eTwo RJ45 communication ports carry CAN communication with the RV5 and Epad, and RS485 pins are reserved for third-party communication.\u003c\/p\u003e\n\u003ch4\u003eWall-Mounted or Recessed\u003c\/h4\u003e\n\u003cp\u003eMount the Epanel on a wall or recess it using the included drilling template. Wood screws hold it to wooden walls, and anchors fit concrete walls.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRVs and camper vans.\u003c\/strong\u003e Run your AC and DC loads from one panel and switch smart circuits from the Epad or your phone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoats.\u003c\/strong\u003e Organize onboard AC and DC circuits in one place, with a protective cover mounted above the panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid buildings.\u003c\/strong\u003e Distribute AC and DC power in an off-grid building from one panel.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eEpanel Versus Separate AC and DC Panels\u003c\/h4\u003e\n\u003cp\u003eSeparate panels mean two boxes and no circuit-level monitoring. The Epanel combines both in one 17 x 13.89 x 4.12 in enclosure with smart circuits you can switch remotely.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eInstallation and Breakers\u003c\/h4\u003e\n\u003cp\u003eBLUETTI states that the Epanel must be installed by a certified technician with proven experience. It accepts 1-inch plug-in breakers that are UL Listed, comply with UL 489 and have a 10,000A short-circuit current rating, from the Eaton BR and C, Thomas \u0026amp; Betts TB and TBBD, Siemens QP and QT, Square D HOM and HOMT, Murray MP-T and MH-T, and General Electric THQL lines. Use branch breakers of 30A or less and a main breaker of 50A or less. Tandem breakers allow up to 16 AC output circuits. Leave at least 4 in (10 cm) of space around the unit. It's rated IP20 and isn't ignition-protected, so don't install it in an engine compartment.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou're building a BLUETTI RV5 system\u003c\/li\u003e\n\u003cli\u003eYou want AC and DC distribution in one panel\u003c\/li\u003e\n\u003cli\u003eYou want to switch circuits from an app or the Epad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eAre Circuit Breakers Included?\u003c\/h4\u003e\n\u003cp\u003eNo. You supply the AC breakers and output cables. AC input cables and DC input cables are also sold separately.\u003c\/p\u003e\n\u003ch4\u003eWhat Happens if a Smart Circuit Trips?\u003c\/h4\u003e\n\u003cp\u003eThe circuit shuts off and tries to restart automatically. If it trips 3 times within 30 minutes, it stays off until you clear the error in the app and turn the power back on.\u003c\/p\u003e\n\u003ch4\u003eHow Often Should I Check the Connections?\u003c\/h4\u003e\n\u003cp\u003eCheck and tighten the AC and DC connections every 3 months, or at least once a month for frequent mobile use. Keep the fan and vents clean.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x BLUETTI Epanel Smart Distribution Panel\u003c\/li\u003e\n\u003cli\u003e8 x ST4.8x25 Wood Screw\u003c\/li\u003e\n\u003cli\u003e8 x Anchor\u003c\/li\u003e\n\u003cli\u003e30 x Blade Fuse (5 Each of 5A, 10A, 15A, 20A, 25A and 30A)\u003c\/li\u003e\n\u003cli\u003e1 x 150A Bolt-On DC Main Fuse\u003c\/li\u003e\n\u003cli\u003e1 x RJ45 Communication Cable (7 ft \/ 2.15 m)\u003c\/li\u003e\n\u003cli\u003e1 x Sticker Set\u003c\/li\u003e\n\u003cli\u003e1 x Drilling Template\u003c\/li\u003e\n\u003cli\u003e1 x Documents (User Manual)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eOne Panel for Your Whole RV5 System\u003c\/h3\u003e\n\u003cp\u003eThe BLUETTI Epanel Smart Distribution Panel brings 8 AC and 20 DC circuits together with app and Epad control of its smart circuits. If you're planning breakers, fuses and wiring for an RV5 installation, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eBLUETTI Epanel Smart Distribution Panel for RV5 Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e120 V \/ 240 V (split-phase with copper busbar removed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz ± 3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Input Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (MAIN1, MAIN2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral and Ground Wiring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG to 6 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A max. (user supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eAC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current per Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Output Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (4 smart with internal switches and power metering, 4 standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBranch Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-inch plug-in, UL Listed, UL 489, 10,000 A SCCR, 30 A max. (user supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTandem Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 16 AC output circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Breaker Lines\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton BR, C; Thomas \u0026amp; Betts TB, TBBD; Siemens QP, QT; Square D HOM, HOMT; Murray MP-T, MH-T; General Electric THQL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 V to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Input Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Port Wiring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 AWG to 2 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-on (150 A DC main fuse included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 V to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current per Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Output Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 (6 smart with internal switches and power metering, 14 standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Port Wiring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 AWG to 10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Fuse Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlade, one per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSmart DC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWarning 20 A, protection 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSmart AC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWarning 30 A, protection 35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Overvoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWarning in app or Epad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Restart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStops after 3 trips within 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSmart Circuit Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 AC and 6 DC circuits via BLUETTI app or Epad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (CAN for RV5 and Epad, RS485 reserved), CAN termination DIP switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 x 13.89 x 4.12 in (431.8 x 352.9 x 104.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 7.7 lbs (3.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-4°F to 113°F (-20°C to 45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Operating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBelow 6,561.68 ft (2,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Clearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt least 4 in (10 cm) on all sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eBLUETTI Epanel Smart Distribution Panel for RV5 Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/bluetti-epanel-smart-distribution-panel-for-rv5-user-manual.pdf\" title=\"BLUETTI Epanel Smart Distribution Panel for RV5 Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/bluetti-epanel-smart-distribution-panel-for-rv5-manual.jpg\" alt=\"BLUETTI Epanel Smart Distribution Panel for RV5 Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Bluetti","offers":[{"title":"Default Title","offer_id":67617408352505,"sku":"A-DB-EPANEL-0424","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/bluetti-epanel-smart-distribution-panel-front-with-its-blue-frame-and-clear-breaker-and-fuse-window.jpg?v=1794005746","url":"https:\/\/outboundpower.com\/products\/bluetti-epanel-smart-distribution-panel-for-rv5","provider":"Outbound Power","version":"1.0","type":"link"}