{"product_id":"faraday-defense-defcon-home-switch-emp-protection-system","title":"Faraday Defense DEFCON Home Switch EMP Protection System","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/black-defcon-home-switch-unit-with-forward-backward-and-push-controls-on-the-front.jpg\" alt=\"Black DEFCON Home Switch unit with Forward, Backward and Push controls on the front\" width=\"1800\" height=\"1217\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Faraday Defense DEFCON Home Switch EMP Protection System Detects an EMP or CME and Trips Your Main Breaker Automatically\u003c\/h2\u003e\n\u003cp\u003eThe DEFCON Home Switch is a detector and breaker actuator in one. Its onboard circuitry detects the E1, E2 and E3 disturbances of an electromagnetic pulse (EMP), as well as the E3-like disturbance of a solar coronal mass ejection (CME). When it detects one, it sounds an alarm and drives a linear actuator that mechanically trips your main breaker, disconnecting the building from the power grid.\u003c\/p\u003e\n\u003cp\u003eIt's for homeowners and business owners who want their main breaker opened without having to be there to do it. It can be installed in nearly any facility with a breaker panel, including offices and workshops, and it's designed to trip up to a 200-amp main breaker. It is made in the USA.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eDEFCON Home Switch EMP Protection System Features\u003c\/h3\u003e\n\u003ch4\u003eAutomatic Main Breaker Shutoff\u003c\/h4\u003e\n\u003cp\u003eOnce an EMP is detected, the Home Switch begins to trip the main breaker. Trip time depends on the breaker, but Faraday says it is typically complete in 1-3 seconds. Faraday designed it to protect the entire home from the conducted E3 disturbances that can come in on the power lines from an EMP or CME.\u003c\/p\u003e\n\u003ch4\u003eDetection Built for Powerful Disturbances\u003c\/h4\u003e\n\u003cp\u003eThe detection circuitry is designed to react only to powerful electromagnetic disturbances, such as those of an EMP or CME, not minor interference. Faraday says it can detect the effects of both high-altitude nuclear EMPs and smaller-scale tactical EMP weapons.\u003c\/p\u003e\n\u003ch4\u003eLinear Actuator With 0.83 In Throw\u003c\/h4\u003e\n\u003cp\u003eThe actuator mounts flush with the main breaker while the breaker is closed and power is flowing. Its 0.83 in linear throw is enough to trip most breakers. The actuator is very quiet, and the breaker makes a snapping sound when it trips.\u003c\/p\u003e\n\u003ch4\u003eManual Actuator Control\u003c\/h4\u003e\n\u003cp\u003eA button on the device lets you move the actuator forward or backward manually, and the front panel is marked Forward, Backward and Push. The unit sounds an alarm while it drives the actuator manually.\u003c\/p\u003e\n\u003ch4\u003eGreen Active Light\u003c\/h4\u003e\n\u003cp\u003eOnce power is applied, the green light comes on to show the Home Switch is active and ready. The label reads \"On, system active\" and \"Off, system inactive.\"\u003c\/p\u003e\n\u003ch4\u003ePlug-In or Hard-Wire Installation\u003c\/h4\u003e\n\u003cp\u003eThe Home Switch comes with detailed installation instructions and the mounting hardware it needs, with instructions for two install options, plug-in or hard-wire. Faraday says no special tools are required. If you choose the hard-wire method, Faraday says it should be connected to the breaker by a licensed electrician.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHomes.\u003c\/strong\u003e Mount the actuator at your main breaker so the house is disconnected from the grid if an EMP or CME is detected, even if no one is home.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOffices and workshops.\u003c\/strong\u003e Faraday says it can be installed in nearly any facility that has a breaker panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBusinesses.\u003c\/strong\u003e Faraday designed it for a home or business, tripping the main breaker on detection the same way.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eDEFCON Home Switch Versus an Alarm-Only EMP Detector\u003c\/h4\u003e\n\u003cp\u003eAn alarm-only detector, such as Faraday's DEFCON EMP Alert System, warns you so you can open the main breaker yourself. The Home Switch detects the same kinds of events and trips the breaker for you, which matters when you're away from the building or can't reach the panel.\u003c\/p\u003e\n\u003ch4\u003ePlug-In Install Versus Hard-Wire Install\u003c\/h4\u003e\n\u003cp\u003eThe plug-in method powers the unit from an outlet. The hard-wire method connects the unit to the breaker, and Faraday says that connection should be made by a licensed electrician. Instructions for both are included.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eChecking Your Breaker Panel\u003c\/h4\u003e\n\u003cp\u003eThe Home Switch was designed to work with numerous types of electrical panels and to trip up to a 200-amp breaker. The actuator's 0.83 in throw trips most breakers. If you're unsure about your panel, have a larger main breaker or need a longer actuator throw, ask our team before you order. If you're not comfortable working at your breaker panel, have a licensed electrician mount it.\u003c\/p\u003e\n\u003ch4\u003ePlacement and Power\u003c\/h4\u003e\n\u003cp\u003eIt isn't designed for outdoor installation, so plan an indoor spot near your panel. It operates from -20 to 100°F and uses about 5 watts normally and about 20 watts while driving the actuator. Faraday's installation instructions cover size and space requirements.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou want your main breaker tripped automatically\u003c\/li\u003e\n\u003cli\u003eYour main breaker is 200 amps or smaller\u003c\/li\u003e\n\u003cli\u003eYou're often away from the building\u003c\/li\u003e\n\u003cli\u003eYour panel is indoors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eCan Lightning Trip the Breaker?\u003c\/h4\u003e\n\u003cp\u003eIt can. Faraday notes that a very strong disturbance, such as a nearby lightning strike, could be detected and cause the device to trip the breaker.\u003c\/p\u003e\n\u003ch4\u003eDoes It Have a Battery Backup?\u003c\/h4\u003e\n\u003cp\u003eNo. When power fails, the unit stops detection and won't trip the breaker until voltage on the power lines rises above its turn-on levels.\u003c\/p\u003e\n\u003ch4\u003eHow Do I Turn It Off?\u003c\/h4\u003e\n\u003cp\u003eUnplug it, or disconnect the wires from the breaker if it's hard-wired. You can also disconnect the actuator using the red and black quick-disconnect connectors built into the actuator cable. To relocate it, remove the actuator and disconnect the power.\u003c\/p\u003e\n\u003ch4\u003eDoes It Need Maintenance?\u003c\/h4\u003e\n\u003cp\u003eNo periodic testing is required or recommended. Faraday lists an expected lifespan of 10-20 years.\u003c\/p\u003e\n\u003ch4\u003eWhat Warranty Does It Have?\u003c\/h4\u003e\n\u003cp\u003eFaraday Defense lists a 1-year warranty.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Faraday Defense DEFCON Home Switch\u003c\/li\u003e\n\u003cli\u003e1 x Linear Actuator With Quick-Disconnect Cable\u003c\/li\u003e\n\u003cli\u003e1 x Mounting Hardware\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eAutomatic Breaker Protection for Your Home\u003c\/h3\u003e\n\u003cp\u003eThe Faraday Defense DEFCON Home Switch EMP Protection System detects EMP and CME disturbances, sounds an alarm and trips main breakers up to 200 amps, typically in 1-3 seconds. If you'd like help confirming it fits your panel or choosing between the plug-in and hard-wire install, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eFaraday Defense DEFCON Home Switch EMP Protection System Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eFit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eFacilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003eHomes, businesses, offices, workshops with a breaker panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned for numerous electrical panel types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor only, not for outdoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDetection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvents Detected\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEMP (E1, E2, E3) and CME (E3-like)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMP Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-altitude nuclear and smaller-scale tactical EMP weapons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReacts only to powerful electromagnetic disturbances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePossible False Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVery strong disturbance such as a nearby lightning strike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSounds alarm and trips main breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 1-3 seconds, depends on breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Throw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlush with breaker in closed position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoves actuator forward or backward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen light, system active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed and black quick-disconnect connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Use, Normal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbout 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Use, Driving Actuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbout 20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 100°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstall Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in or hard-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHard-Wire Install\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy a licensed electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial Tools\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetailed installation instructions included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.25 x 3.75 x 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth Across Mounting Tabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTYPE-H1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMade In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Lifespan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo periodic testing required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Faraday Defense","offers":[{"title":"Default Title","offer_id":67619946397945,"sku":"14053","price":589.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/faraday-defense-defcon-home-switch-emp-protection-system-front-panel-with-green-active-light-and-three-prong-power-cord.jpg?v=1794020709","url":"https:\/\/outboundpower.com\/products\/faraday-defense-defcon-home-switch-emp-protection-system","provider":"Outbound Power","version":"1.0","type":"link"}