{"product_id":"firman-p01204-gasoline-1200w-1500w-portable-generator-recoil-start-co-alert","title":"Firman P01204 Gasoline 1200W\/1500W Portable Generator | Recoil Start | CO Alert","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p01204-gasoline-open-frame-generator-on-pine-needles-in-front-of-a-log-cabin-porch.jpg\" alt=\"Firman P01204 gasoline open frame generator on pine needles in front of a log cabin porch\" width=\"1800\" height=\"1800\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Firman P01204 Gasoline 1200W\/1500W Portable Generator Gives You Simple, Light Power for Camping and Tailgating\u003c\/h2\u003e\n\u003cp\u003eThe Firman P01204 is a compact 120V gasoline open frame generator built on an 80cc Firman OHV engine. It delivers 1500 starting watts and 1200 running watts, and its 1.7-gallon steel tank gives you up to 10 hours of run time at 50% load.\u003c\/p\u003e\n\u003cp\u003eAt 54 lbs, it's made for people on the go who want basic power for camping, tailgating and other outdoor activities. Recoil start means there's no starter battery to keep charged, and Firman CO Alert shutdown comes standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eFirman P01204 Gasoline 1200W\/1500W Portable Generator Features\u003c\/h3\u003e\n\u003ch4\u003e80cc OHV Engine With Recoil Start\u003c\/h4\u003e\n\u003cp\u003eThe single cylinder, 4-stroke Firman engine has a cast iron sleeve and a float carburetor. To start it, open the fuel valve, flip the engine switch to ON, set the choke and pull the recoil starter. With no electric start system, there's no battery to look after between trips.\u003c\/p\u003e\n\u003ch4\u003eCO Alert Automatic Shutdown\u003c\/h4\u003e\n\u003cp\u003eCO Alert shuts the engine down when harmful levels of carbon monoxide build up around the generator, or if a CO Alert fault occurs. A yellow light blinks for five seconds at startup to show the system is working, and a red light tells you the engine stopped because CO built up. CO Alert does not replace carbon monoxide alarms, so Firman tells you to install battery-powered CO alarms in your home.\u003c\/p\u003e\n\u003ch4\u003eOne 5-20R Duplex for Everyday Plugs\u003c\/h4\u003e\n\u003cp\u003eThe covered control panel has a 5-20R 120V 20A duplex, so you can plug in two cords at once. A circuit breaker protects the receptacles if the generator is overloaded or a short occurs. Keep the total load within the 1200 running watts, since the combined draw must not exceed the data decal rating.\u003c\/p\u003e\n\u003ch4\u003e1.7-Gallon Steel Tank With Fuel Gauge\u003c\/h4\u003e\n\u003cp\u003eThe steel tank holds 1.7 U.S. gallons (6.4L) and gives you up to 10 hours at 50% load. A fuel gauge shows the level at a glance, and a red fuel level indicator shows where to stop filling so there's room for fuel expansion.\u003c\/p\u003e\n\u003ch4\u003eLight Open Frame at 54 Lbs\u003c\/h4\u003e\n\u003cp\u003eFirman built the P01204 around a lightweight open frame, and the whole unit weighs 54 lbs. That makes it easy to bring along in the car for a weekend away or a game day.\u003c\/p\u003e\n\u003ch4\u003eLow Oil Shutdown Protection\u003c\/h4\u003e\n\u003cp\u003eIf the oil level drops below the minimum, a sensor stops the engine before damage can happen. Check the oil before each use or at least every 8 hours of running, change it after the first 25 hours, then every 100 hours.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCamping.\u003c\/strong\u003e Run lights and small appliances at the campsite, with the generator set at least 20 ft from tents and campers and the exhaust pointed away.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTailgating.\u003c\/strong\u003e Power lights, small appliances and device chargers in the parking lot through an outdoor-rated extension cord.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutdoor chores and hobbies.\u003c\/strong\u003e Plug in a work light or a small corded tool away from an outlet, as long as its starting load fits within 1500 watts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLast-minute power.\u003c\/strong\u003e Keep it on hand for events and recreation where you need a little power without a large generator.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eFirman P01204 Versus Firman W02081\u003c\/h4\u003e\n\u003cp\u003eThe W02081 is a 2000 running and 2500 starting watt inverter generator that weighs 42.9 lbs. It adds an L5-30R outlet, USB-A and USB-C ports, a 12V DC outlet, economy mode and parallel capability. The P01204 is a simpler open frame design with a larger 1.7-gallon tank, versus 1.1 gallons on the W02081.\u003c\/p\u003e\n\u003ch4\u003eFirman P01204 Versus Firman P03504\u003c\/h4\u003e\n\u003cp\u003eThe P03504 steps up to a 208cc engine, 3550 running and 4450 starting watts, a 5-gallon tank and L5-30R and TT-30R outlets for RVs. It weighs 108 lbs on 8\" wheels. The P01204 is half that weight, which matters when you carry it by hand.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003ePlacement and Extension Cords\u003c\/h4\u003e\n\u003cp\u003eRun the generator outdoors only, at least 20 ft from occupied spaces with the exhaust pointed away, and at least 5 ft from structures, trees or tall vegetation. Use grounded, outdoor-rated extension cords sized for your load. Firman does not recommend running extension cords directly into your home to power indoor items. The manual also says the generator is not intended for use at a construction site as defined by NEC section 590.6.\u003c\/p\u003e\n\u003ch4\u003eFloating Neutral and California\u003c\/h4\u003e\n\u003cp\u003eThe neutral is floating, so the outlet ground pins are not functional, and devices that need a working ground pin, such as a plug-in GFCI, won't operate. The duplex itself is not GFCI protected. Firman states this unit is not certified to ship to California, so it can't be sold or shipped there.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou want a light gasoline generator you can carry by hand\u003c\/li\u003e\n\u003cli\u003eYour loads add up to 1200 running watts or less\u003c\/li\u003e\n\u003cli\u003eYou prefer recoil start with no battery to maintain\u003c\/li\u003e\n\u003cli\u003eYou want automatic CO shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eHow Long Does the P01204 Run on a Tank?\u003c\/h4\u003e\n\u003cp\u003eFirman rates it at up to 10 hours of run time at 50% load on the 1.7-gallon tank.\u003c\/p\u003e\n\u003ch4\u003eHow Loud Is It?\u003c\/h4\u003e\n\u003cp\u003eFirman lists 74 dB at 7m and 75% load.\u003c\/p\u003e\n\u003ch4\u003eWhat About Sensitive Electronics?\u003c\/h4\u003e\n\u003cp\u003eFirman notes a remote chance that voltage fluctuations may affect sensitive electronics such as computers. It recommends a plug-in surge suppressor on the receptacle feeding that equipment.\u003c\/p\u003e\n\u003ch4\u003eCan I Use It at High Altitude?\u003c\/h4\u003e\n\u003cp\u003eYes, with reduced output. Engine power and generator output drop by about 3.5% for every 1,000 feet above sea level. Firman can supply high altitude carburetor main jets for 3,000 to 8,000 feet through customer support.\u003c\/p\u003e\n\u003ch4\u003eWhat Warranty Does It Have?\u003c\/h4\u003e\n\u003cp\u003eThe P01204 has a Firman 3-year limited warranty, with 1 year of parts and labor and 3 years of parts and technical support for the original purchaser. Commercial and industrial use is covered for 90 days parts and labor and 180 days parts. Register within 10 days of purchase.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Firman P01204 Gasoline Portable Generator\u003c\/li\u003e\n\u003cli\u003e1 x Engine Oil Bottle\u003c\/li\u003e\n\u003cli\u003e1 x Oil Funnel\u003c\/li\u003e\n\u003cli\u003e1 x Spark Plug Wrench\u003c\/li\u003e\n\u003cli\u003e1 x Set of Double Open-Ended Wrenches (10mm x 12mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eSimple Power You Can Carry\u003c\/h3\u003e\n\u003cp\u003eThe Firman P01204 Gasoline 1200W\/1500W Portable Generator gives you recoil start simplicity, a 1.7-gallon steel tank, CO Alert shutdown and a 54 lb open frame you can take almost anywhere. If you'd like help adding up your watts or picking the right size, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eFirman P01204 Videos\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ciframe title=\"Firman Performance Series Overview\" loading=\"lazy\" height=\"300\" width=\"550\" style=\"max-width: 100%; max-height: 100%; padding: 5px; margin: 20px auto;\" src=\"https:\/\/player.vimeo.com\/video\/1116915102\" allow=\"fullscreen; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003ciframe title=\"Firman Performance Series unboxing\" loading=\"lazy\" height=\"300\" width=\"550\" style=\"max-width: 100%; max-height: 100%; padding: 5px; margin: 20px auto;\" src=\"https:\/\/player.vimeo.com\/video\/1116924544\" allow=\"fullscreen; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003ciframe title=\"Firman CO Alert Safety Information\" loading=\"lazy\" height=\"300\" width=\"550\" style=\"max-width: 100%; max-height: 100%; padding: 5px; margin: 20px auto;\" src=\"https:\/\/player.vimeo.com\/video\/754833137\" allow=\"fullscreen; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eFirman P01204 Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eStarting Watts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e1500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Watts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated AC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Regulator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrushless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eEngine and Fuel\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFIRMAN single cylinder, 4-stroke OHV, air cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCylinder Sleeve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecoil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreakless ignition, flywheel magneto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnleaded automotive gasoline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasoline Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 octane minimum, no more than 10% ethanol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 U.S. gallons (6.4L), steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10 hours at 50% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLubricating Oil Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.9 oz (0.38L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarburetor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Cleaner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyurethane type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 dB at 7m and 75% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous operation up to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutlets and Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5-20R 120V 20A Duplex (Not GFCI Protected)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChoke Lever\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO Alert Indicator Light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlet Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSafety and Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO Alert\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, automatic engine shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Oil Shutdown\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Grounding System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloating neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpark Arrester\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Capable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo parallel port listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL, EPA, NOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 100-14; ANSI\/PGMA G300-2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalifornia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot certified to ship to California\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidential Coverage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year parts and labor; 3 years parts and technical support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommercial and Industrial Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 days parts and labor; 180 days parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmissions Control System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eFirman P01204 Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p01204-manual.pdf\" title=\"Firman P01204 Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p01204-manual.jpg\" alt=\"Firman P01204 Manual\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch4\u003eFirman P01204 Quick Start Guide\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p01204-quick-start-guide.pdf\" title=\"Firman P01204 Quick Start Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p01204-quick-start-guide.jpg\" alt=\"Firman P01204 Quick Start Guide\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003e⚠ WARNING:\u003c\/strong\u003e Cancer and Reproductive \u003cspan style=\"white-space: nowrap;\"\u003eHarm – \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\" title=\"California Proposition 65 warnings\" rel=\"noopener\" target=\"_blank\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Firman Power Equipment","offers":[{"title":"Default Title","offer_id":67595971395833,"sku":"P01204","price":469.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p01204-gasoline-1200w-1500w-portable-generator-front-three-quarter-view-showing-the-co-alert-control-panel-and-open-frame.jpg?v=1793776276","url":"https:\/\/outboundpower.com\/products\/firman-p01204-gasoline-1200w-1500w-portable-generator-recoil-start-co-alert","provider":"Outbound Power","version":"1.0","type":"link"}