{"product_id":"firman-p03504-gasoline-3550w-4450w-portable-generator-recoil-start-co-alert","title":"Firman P03504 Gasoline 3550W\/4450W Portable Generator | Recoil Start | CO Alert","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p03504-gasoline-generator-running-a-welder-in-the-snow-beside-a-ranch-fence.jpg\" alt=\"Firman P03504 gasoline generator running a welder in the snow beside a ranch fence\" width=\"1800\" height=\"1800\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Firman P03504 Gasoline 3550W\/4450W Portable Generator Delivers RV Ready 120V Power With Recoil Start and CO Alert\u003c\/h2\u003e\n\u003cp\u003eThe Firman P03504 is a 120V gasoline open frame generator built on a 208cc Firman OHV engine. It delivers 4450 starting watts and 3550 running watts, and its 5-gallon steel tank gives you up to 14 hours of run time at 50% load.\u003c\/p\u003e\n\u003cp\u003eIt's made for outdoor trips, home projects and backup use where you want simple, dependable 120V power. Recoil start means there's no starter battery to keep charged, and an RV ready TT-30R outlet, an L5-30R twist lock, a 4-1 Data-Minder and Firman CO Alert shutdown all come standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eFirman P03504 Gasoline 3550W\/4450W Portable Generator Features\u003c\/h3\u003e\n\u003ch4\u003eRV Ready Control Panel\u003c\/h4\u003e\n\u003cp\u003eThe covered panel has a TT-30R 120V 30A RV outlet, an L5-30R 120V 30A twist lock and a 5-20R 120V 20A duplex. Circuit breakers protect the receptacles if the generator is overloaded or a short occurs. Keep the total load within 3550 running watts, since the combined draw must not exceed the data decal rating.\u003c\/p\u003e\n\u003ch4\u003eCO Alert Automatic Shutdown\u003c\/h4\u003e\n\u003cp\u003eCO Alert shuts the engine down when harmful levels of carbon monoxide build up around the generator, or if a CO Alert fault occurs. A yellow light blinks for five seconds at startup to show the system is working. CO Alert does not replace carbon monoxide alarms, so Firman tells you to install battery-powered CO alarms in your home.\u003c\/p\u003e\n\u003ch4\u003e4-1 Data-Minder\u003c\/h4\u003e\n\u003cp\u003ePress SELECT to see voltage, hertz, running hours and the low oil alarm on one display. Running hours help you track the first oil change at 25 hours and each 100-hour change after that.\u003c\/p\u003e\n\u003ch4\u003eSimple Recoil Start\u003c\/h4\u003e\n\u003cp\u003eOpen the fuel valve, flip the engine switch to ON, set the choke and pull the recoil starter. With no electric start system, there's no battery to maintain between uses.\u003c\/p\u003e\n\u003ch4\u003e5-Gallon Steel Tank With Fuel Gauge\u003c\/h4\u003e\n\u003cp\u003eThe steel tank holds 5 U.S. gallons (19L) and gives you up to 14 hours at 50% load. A fuel gauge shows the level, so you know when to refill before the engine runs dry.\u003c\/p\u003e\n\u003ch4\u003eCast Iron Sleeve, AVR and Low Oil Shutdown\u003c\/h4\u003e\n\u003cp\u003eThe 208cc engine has a cast iron sleeve, and an automatic voltage regulator (AVR) controls the output voltage as loads change. If the oil level drops below the minimum, a sensor stops the engine, which helps protect it.\u003c\/p\u003e\n\u003ch4\u003eFlat Free Wheels and a Bottle Opener\u003c\/h4\u003e\n\u003cp\u003eAt 108 lbs, the P03504 rolls on 8.0\" flat free wheels with a handle. It also has a built-in bottle opener, which comes in handy at the campsite.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRV trips and camping.\u003c\/strong\u003e Plug your camper into the TT-30R outlet and run its 120V systems, with the generator at least 20 ft from the RV's windows and doors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHome projects.\u003c\/strong\u003e Power tools, work lights and appliances through outdoor-rated extension cords from the L5-30R or the 5-20R duplex.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackup power.\u003c\/strong\u003e Firman lists backup power among its uses. Keep the generator outdoors at least 20 ft from occupied spaces and follow the manual's extension cord guidance, which does not recommend running cords directly into your home.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eFirman P03504 Versus Firman P03503\u003c\/h4\u003e\n\u003cp\u003eThe P03503 is a close sibling with the same 3550 running and 4450 starting watt rating, 208cc engine, 5-gallon tank, outlet layout and CO Alert. Firman includes a generator cover with the P03503 and lists it at 109 lbs. No cover is listed with the P03504, which comes in at 108 lbs.\u003c\/p\u003e\n\u003ch4\u003eFirman P03504 Versus Firman P03613\u003c\/h4\u003e\n\u003cp\u003eThe P03613 has the same outlets, tank, recoil start and CO Alert, with a higher rating of 3650 running and 4550 starting watts. It weighs 108.5 lbs. Choose the P03613 if you want the extra 100 watts, or the P03504 if 3550 running watts covers your loads.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003ePlacement and Extension Cords\u003c\/h4\u003e\n\u003cp\u003eRun the generator outdoors only, at least 20 ft from occupied spaces with the exhaust pointed away, and at least 5 ft from structures. Use grounded, outdoor-rated extension cords sized for your load. The manual says the generator is not intended for use at a construction site as defined by NEC section 590.6.\u003c\/p\u003e\n\u003ch4\u003eFloating Neutral and California\u003c\/h4\u003e\n\u003cp\u003eThe neutral is floating, so the outlet ground pins are not functional, and devices that need a working ground pin, such as a plug-in GFCI, won't operate. The 5-20R duplex is not GFCI protected. Firman states this unit is not certified to ship to California, so it can't be sold or shipped there.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need a TT-30R outlet for your RV\u003c\/li\u003e\n\u003cli\u003eYou want a gasoline generator with no battery to maintain\u003c\/li\u003e\n\u003cli\u003eYou want automatic CO shutdown\u003c\/li\u003e\n\u003cli\u003eYour loads fit within 3550 running watts at 120V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eHow Long Does the P03504 Run on a Tank?\u003c\/h4\u003e\n\u003cp\u003eFirman rates it at up to 14 hours of run time at 50% load on the 5-gallon tank.\u003c\/p\u003e\n\u003ch4\u003eHow Loud Is It?\u003c\/h4\u003e\n\u003cp\u003eFirman lists 75 dB at 7m and 75% load.\u003c\/p\u003e\n\u003ch4\u003eCan It Power My RV?\u003c\/h4\u003e\n\u003cp\u003eThe TT-30R is a 120V 30A RV outlet. Keep the total load within the generator's 3550 running watts, since total power drawn from all receptacles must not exceed the data decal rating.\u003c\/p\u003e\n\u003ch4\u003eCan I Use It at High Altitude?\u003c\/h4\u003e\n\u003cp\u003eYes, with reduced output. Engine power and generator output drop by about 3.5% for every 1,000 feet above sea level. Firman can supply high altitude carburetor main jets for 3,000 to 8,000 feet through customer support.\u003c\/p\u003e\n\u003ch4\u003eWhat Warranty Does It Have?\u003c\/h4\u003e\n\u003cp\u003eThe P03504 has a Firman 3-year limited warranty, with 1 year of parts and labor and 3 years of parts and technical support for the original purchaser. Commercial and industrial use is covered for 90 days parts and labor and 180 days parts. Register within 10 days of purchase.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Firman P03504 Gasoline Portable Generator\u003c\/li\u003e\n\u003cli\u003e1 x Engine Oil Bottle\u003c\/li\u003e\n\u003cli\u003e1 x Oil Funnel\u003c\/li\u003e\n\u003cli\u003e1 x Spark Plug Wrench\u003c\/li\u003e\n\u003cli\u003e2 x Double Open-Ended Wrench (10mm x 12mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eDependable 120V Power for Trips and Projects\u003c\/h3\u003e\n\u003cp\u003eThe Firman P03504 Gasoline 3550W\/4450W Portable Generator gives you recoil start simplicity, a 5-gallon steel tank, an RV ready TT-30R outlet and CO Alert shutdown. If you have questions about outlets, run time or sizing, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eFirman P03504 Videos\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ciframe title=\"Firman P03504 Overview\" loading=\"lazy\" height=\"300\" width=\"550\" style=\"max-width: 100%; max-height: 100%; padding: 5px; margin: 20px auto;\" src=\"https:\/\/player.vimeo.com\/video\/664933009\" allow=\"fullscreen; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003ciframe title=\"Firman Performance Series Unboxing\" loading=\"lazy\" height=\"300\" width=\"550\" style=\"max-width: 100%; max-height: 100%; padding: 5px; margin: 20px auto;\" src=\"https:\/\/player.vimeo.com\/video\/1116924544\" allow=\"fullscreen; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003ciframe title=\"Firman CO Alert Safety Information\" loading=\"lazy\" height=\"300\" width=\"550\" style=\"max-width: 100%; max-height: 100%; padding: 5px; margin: 20px auto;\" src=\"https:\/\/player.vimeo.com\/video\/754833137\" allow=\"fullscreen; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eFirman P03504 Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eStarting Watts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e4450W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Watts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3550W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated AC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Regulator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrushed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eEngine and Fuel\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFIRMAN single cylinder, 4-stroke OHV, air cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCylinder Sleeve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecoil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreakless ignition, flywheel magneto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnleaded automotive gasoline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasoline Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 octane minimum, no more than 10% ethanol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Tank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 U.S. gallons (19L), steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 14 hours at 50% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLubricating Oil Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.3 oz (0.6L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarburetor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Cleaner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyurethane type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 dB at 7m and 75% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous operation up to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutlets and Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5-20R 120V 20A Duplex (Not GFCI Protected)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eL5-30R 120V 30A Twist Lock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTT-30R 120V 30A RV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData-Minder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-1 (voltage, hertz, running hours, low oil alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Circuit Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlet Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBottle Opener\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWheels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0\" (20.3cm) flat free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHandle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSafety and Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO Alert\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, automatic engine shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Oil Shutdown\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Grounding System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloating neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpark Arrester\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Capable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo parallel port listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL, EPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 100-14; ANSI\/PGMA G300-2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalifornia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot certified to ship to California\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidential Coverage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year parts and labor; 3 years parts and technical support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommercial and Industrial Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 days parts and labor; 180 days parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmissions Control System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eFirman P03504 Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p03504-manual.pdf\" title=\"Firman P03504 Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p03504-manual.jpg\" alt=\"Firman P03504 Manual\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch4\u003eFirman P03504 Electrical Schematic\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p03504-electrical-schematic.pdf\" title=\"Firman P03504 Electrical Schematic\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p03504-electrical-schematic.jpg\" alt=\"Firman P03504 Electrical Schematic\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003e⚠ WARNING:\u003c\/strong\u003e Cancer and Reproductive \u003cspan style=\"white-space: nowrap;\"\u003eHarm – \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\" title=\"California Proposition 65 warnings\" rel=\"noopener\" target=\"_blank\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Firman Power Equipment","offers":[{"title":"Default Title","offer_id":67595974246649,"sku":"P03504","price":749.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/firman-p03504-gasoline-3550w-4450w-portable-generator-front-three-quarter-view-with-the-co-alert-control-panel-and-flat-free-wheels.jpg?v=1793776467","url":"https:\/\/outboundpower.com\/products\/firman-p03504-gasoline-3550w-4450w-portable-generator-recoil-start-co-alert","provider":"Outbound Power","version":"1.0","type":"link"}