{"product_id":"generac-breather-heater-for-air-cooled-home-standby-generators-120v-6-5w-2013-to-2025-units","title":"Generac Breather Heater for Air-Cooled Home Standby Generators | 120V 6.5W | 2013 to 2025 Units","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-breather-heater-7103-cable-with-spiral-element-for-standby-generator-engines.jpg?v=1793847694\" alt=\"Generac breather heater 7103 cable with spiral element for standby generator engines\" width=\"1500\" height=\"1500\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Generac Breather Heater for Air-Cooled Home Standby Generators Fights Icing in Extreme Cold\u003c\/h2\u003e\n\u003cp\u003eThe Generac Breather Heater, kit 7103, is a 120V heater that wraps around the engine breather hose. It is only for use in extreme cold weather applications, with icing in mind.\u003c\/p\u003e\n\u003cp\u003eGenerac says it is only compatible with units manufactured 2013 to 2025. It needs an Evolution controller. Generac lists it for Guardian Series 10 kW to 26 kW and Next Generation Series 10 kW to 28 kW air-cooled units.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eGenerac Breather Heater for Air-Cooled Home Standby Generators Features\u003c\/h3\u003e\n\u003ch4\u003eMade for Extreme Cold\u003c\/h4\u003e\n\u003cp\u003eGenerac recommends it at 0 degrees F or below. It is meant for extreme cold weather applications only.\u003c\/p\u003e\n\u003ch4\u003eLow Power Draw\u003c\/h4\u003e\n\u003cp\u003eGenerac lists 120V, 6.5 watts and 0.054 amps at 60 Hz. It connects to T1 and Neutral.\u003c\/p\u003e\n\u003ch4\u003eAutomatic Control\u003c\/h4\u003e\n\u003cp\u003eIt turns on at 40 degrees F and off at 55 degrees F.\u003c\/p\u003e\n\u003ch4\u003eSilicone Tape Provided\u003c\/h4\u003e\n\u003cp\u003eThe heater wraps around the breather hose and is secured with the silicone tape that comes with it.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDeep Winter Climates.\u003c\/strong\u003e Add it where temperatures drop to 0 degrees F or below.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandby Units With Evolution Controllers.\u003c\/strong\u003e Generac says the heater requires the Evolution controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cold Weather Setup.\u003c\/strong\u003e Pair it with the battery and oil filter heaters if your climate calls for all three.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVersus the Battery and Oil Filter Heaters.\u003c\/strong\u003e Those two are recommended at 32 degrees F or below. The breather heater is for extreme cold at 0 degrees F or below.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersus No Breather Heater.\u003c\/strong\u003e In extreme cold the breather can ice up. This heater warms it as the thermostat calls for heat.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eIs the Breather Heater the Right Fit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits.\u003c\/strong\u003e Units manufactured 2013 to 2025 with the Evolution controller, Guardian 10 kW to 26 kW and Next Generation 10 kW to 28 kW air-cooled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil change required.\u003c\/strong\u003e Generac requires that the oil be replaced with 5W-30 synthetic when you install any cold weather item.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation.\u003c\/strong\u003e Qualified personnel only. Leads connect to T1 and the neutral stud in the customer connection panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis May Be a Good Fit If\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYour generator is a 2013 to 2025 unit with an Evolution controller.\u003c\/li\u003e\n\u003cli\u003eYou face extreme cold with icing at 0 degrees F or below.\u003c\/li\u003e\n\u003cli\u003eYou want a low-wattage heater that cycles by itself.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhich generators does this fit?\u003c\/h4\u003e\n\u003cp\u003eGenerac lists units manufactured 2013 to 2025, Guardian Series 10 kW to 26 kW and Next Generation Series 10 kW to 28 kW. It requires the Evolution controller.\u003c\/p\u003e\n\u003ch4\u003eWhen do I need it?\u003c\/h4\u003e\n\u003cp\u003eGenerac recommends it only in extreme cold, 0 degrees F or below.\u003c\/p\u003e\n\u003ch4\u003eWhat oil is required?\u003c\/h4\u003e\n\u003cp\u003eGenerac requires that the oil be replaced with 5W-30 synthetic when you install any cold weather item.\u003c\/p\u003e\n\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\n\u003cp\u003eThe heater has a one-year limited warranty.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Breather Heater\u003c\/li\u003e\n\u003cli\u003e1 x Silicone Tape\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eProtection Against Breather Icing\u003c\/h3\u003e\n\u003cp\u003eThe Generac Breather Heater for Air-Cooled Home Standby Generators is built for the cold-weather needs of your standby generator. Questions about fit for your unit? The Outbound Power team is glad to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eGenerac Breather Heater for Air-Cooled Home Standby Generators Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG0071032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGenerac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreather heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnits manufactured 2013 to 2025; requires Evolution controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGuardian 10 kW to 26 kW and Next Generation 10 kW to 28 kW air-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWattage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.054 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHertz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection in Generator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT1 and Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurns ON \/ OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 F (4 C) \/ 55 F (13 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Climate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 F (-18 C) or below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5W-30 synthetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreather heater, silicone tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eGenerac 7103 Breather Heater Spec Sheet\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-cold-weather-kits-spec-sheet.pdf?v=1793847695\" title=\"Generac 7103 Breather Heater Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-7103-breather-heater-spec-sheet.jpg?v=1793847694\" alt=\"Generac 7103 Breather Heater Spec Sheet\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Generac","offers":[{"title":"Default Title","offer_id":67602842190073,"sku":"7103","price":150.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-7103-breather-heater-a-coiled-white-cable-with-an-orange-spiral-heating-element-and-ring-terminal-leads.jpg?v=1793847694","url":"https:\/\/outboundpower.com\/products\/generac-breather-heater-for-air-cooled-home-standby-generators-120v-6-5w-2013-to-2025-units","provider":"Outbound Power","version":"1.0","type":"link"}