{"product_id":"generac-next-gen-10kw-home-standby-generator-air-cooled-cellular-bluetooth-wifi-enabled","title":"Generac Next-Gen 10kW Home Standby Generator | Air-Cooled | Cellular, Bluetooth \u0026 WiFi Enabled","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10kw-air-cooled-standby-generator-viewed-from-the-front-corner.jpg?v=1793844951\" alt=\"Generac Next-Gen 10kW air-cooled standby generator viewed from the front corner\" width=\"1500\" height=\"1500\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Generac Next-Gen 10kW Home Standby Generator Restores Power to Smaller Homes Automatically Within Seconds of an Outage\u003c\/h2\u003e\n\u003cp\u003eThe Generac Next-Gen 10kW (model G0072570) is the smallest model in Generac's Next-Gen air-cooled standby line. It is rated for 10kW on liquid propane (LP) and 9kW on natural gas (NG), starts on its own when utility power fails and shuts down after the grid returns. A single-cylinder 459cc G-Force engine keeps it compact and quiet, at 61 dB(A) under normal load.\u003c\/p\u003e\n\u003cp\u003eGenerac's own sizing guide points a 10kW unit at whole-house backup for homes up to about 1,500 square feet, or essential circuits in a larger home. You can order it alone or bundled with a 100A automatic transfer switch that has a 16-space, 24-circuit load center built in.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eGenerac Next-Gen 10kW Home Standby Generator Features\u003c\/h3\u003e\n\u003ch4\u003eAutomatic Starts When the Power Goes Out\u003c\/h4\u003e\n\u003cp\u003eThe Power Zone 200 controller watches utility voltage around the clock. When voltage drops below the dropout setting (75 to 80% of nominal), the generator starts, warms up and takes the load through the transfer switch. When utility power returns, it transfers back and cools down before shutting off, with no one needing to be home.\u003c\/p\u003e\n\u003ch4\u003eCellular Monitoring Is Standard\u003c\/h4\u003e\n\u003cp\u003eA Generac Generator Connectivity Accessory with cellular service ships in the box, and the unit also has Wi-Fi and Bluetooth capability. Through the Mobile Link app you can check generator status, exercise and run hours, maintenance information and monthly reports, and you can connect your account to an authorized service dealer. Some Mobile Link features require a premium subscription.\u003c\/p\u003e\n\u003ch4\u003eElectronic Fuel and Ignition Control\u003c\/h4\u003e\n\u003cp\u003eElectronic fuel and ignition control (EFIC) adjusts the engine for changing conditions. Generac says it improves fuel efficiency and lowers emissions on average compared with its Guardian Series units, and hydraulic lifters keep valve spacing set so you never adjust valves by hand.\u003c\/p\u003e\n\u003ch4\u003eClean Power for Sensitive Electronics\u003c\/h4\u003e\n\u003cp\u003eGenerac's True Power technology holds total harmonic distortion below 5%, and digital voltage regulation holds output within about 1%. That clean sine wave suits computers, smart appliances and variable-speed HVAC equipment.\u003c\/p\u003e\n\u003ch4\u003eLower Maintenance and Smarter Exercise\u003c\/h4\u003e\n\u003cp\u003eOil change intervals run up to 2 years or 200 hours, and an oil level sensor reports oil level for you. Smart Exercise runs the engine for 5 minutes each week by default, or bi-weekly or monthly for 5 to 20 minutes, and it skips a scheduled run if the generator already ran more than 5 minutes in the prior 72 hours.\u003c\/p\u003e\n\u003ch4\u003eBuilt for Snow, Wind and Tight Lots\u003c\/h4\u003e\n\u003cp\u003eA sloped roof and rear air intake reduce snow and ice intrusion, and Generac rates the sound-attenuated aluminum enclosure for winds up to 150 mph. The unit is listed by the Southwest Research Institute for installation as close as 18 in from a structure, away from doors, windows and fresh air intakes and in line with local codes.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSmaller homes and condos.\u003c\/strong\u003e Generac's sizing guide lists a 10kW unit for a 3-ton air conditioner, kitchen, furnace, sump pump, one bathroom, two bedrooms, living areas and a well pump or water heater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEssential circuits in a larger home.\u003c\/strong\u003e Pair it with the 16-circuit transfer switch to back up the circuits that matter most, such as the furnace, refrigerator, sump pump and lights.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorm-prone areas.\u003c\/strong\u003e Automatic starts and cellular monitoring mean the house stays powered and you get status updates even when you are away.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHomes on natural gas.\u003c\/strong\u003e Run it from your existing gas service for long outages without refueling.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eHow the 10kW Compares\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVersus the \u003ca href=\"\/products\/generac-next-gen-14kw-home-standby-generator-air-cooled-cellular-bluetooth-wifi-enabled\"\u003eGenerac Next-Gen 14kW\u003c\/a\u003e.\u003c\/strong\u003e The 14kW uses a two-cylinder 817cc engine and is rated 14kW on both fuels with a 60A breaker. The 10kW uses a single-cylinder 459cc engine, weighs 344 lb instead of 391 lb and runs quieter at 61 dB(A) versus 65 dB(A). Both share the same 46.4 x 26.3 x 30.7 in enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersus a portable generator.\u003c\/strong\u003e A portable generator has to be wheeled out, refueled and connected by hand during every outage. A home standby generator is permanently installed, runs on your gas supply and starts on its own, even when you are away or an outage lasts for days.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eIs the Generac Next-Gen 10kW the Right Fit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel.\u003c\/strong\u003e Natural gas service, or an LP tank sized for full-load fuel use. The unit is factory-configured for natural gas and is converted on site for LP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSite.\u003c\/strong\u003e A level base of pea gravel, crushed stone or concrete, 3 ft of clearance at the front and ends, 18 in at the rear and 5 ft overhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation.\u003c\/strong\u003e Installation by a licensed electrician or authorized Generac dealer, following local codes. Installation is not included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery.\u003c\/strong\u003e A 12V AGM Group BTX30L battery with at least 400 CCA, sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis May Be a Good Fit If\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou want automatic backup for a home up to about 1,500 sq ft\u003c\/li\u003e\n\u003cli\u003eYou want to back up essential circuits in a larger home\u003c\/li\u003e\n\u003cli\u003eYou prefer a quieter single-cylinder unit\u003c\/li\u003e\n\u003cli\u003eYou want cellular monitoring included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eIs a Battery Included?\u003c\/h4\u003e\n\u003cp\u003eNo. Generac specifies a 12V AGM Powersport Group BTX30L battery with at least 400 CCA. The generator includes the battery tray, cables and a positive terminal cover.\u003c\/p\u003e\n\u003ch4\u003eDoes It Need Wi-Fi to Connect?\u003c\/h4\u003e\n\u003cp\u003eNo. Cellular connectivity is standard, so Mobile Link works without your home network, and the unit can also use Wi-Fi and Bluetooth. Some Mobile Link features require a premium subscription.\u003c\/p\u003e\n\u003ch4\u003eWhat Maintenance Does It Need?\u003c\/h4\u003e\n\u003cp\u003eOil changes run up to every 2 years or 200 hours, and the unit exercises itself on the schedule you set. Generac's spec sheet lists scheduled maintenance kit G006482-0 for this model, with oil sold separately.\u003c\/p\u003e\n\u003ch4\u003eWhat Is the Warranty?\u003c\/h4\u003e\n\u003cp\u003eGenerac's 5-year limited warranty covers the generator and Generac transfer switch for 5 years or 2,000 hours. Years 1 and 2 cover parts, labor and limited travel, year 3 covers parts, and years 4 and 5 cover major engine and alternator components. The unit must be registered and serviced by an Independent Authorized Service Dealer.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Generac Next-Gen 10kW Home Standby Generator With Pre-Mounted Base Pad\u003c\/li\u003e\n\u003cli\u003e1 x Generac Generator Connectivity Accessory, Cellular\u003c\/li\u003e\n\u003cli\u003e1 x Flexible Fuel Line\u003c\/li\u003e\n\u003cli\u003e1 x Battery Tray\u003c\/li\u003e\n\u003cli\u003e1 x Positive Battery Terminal Cover\u003c\/li\u003e\n\u003cli\u003e1 x Set of Keys\u003c\/li\u003e\n\u003cli\u003e1 x Set of Back Panel Plugs\u003c\/li\u003e\n\u003cli\u003e1 x Owner's Manual and Installation Manual\u003c\/li\u003e\n\u003cli\u003e1 x 100A 16-Circuit Automatic Transfer Switch (Transfer Switch Option Only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe starting battery is sold separately.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eDependable Backup Power for Your Home\u003c\/h3\u003e\n\u003cp\u003eThe Generac Next-Gen 10kW gives your home automatic, monitored backup power on natural gas or propane, with Generac's 5-year limited warranty behind it. At Outbound Power we help you match the right generator size and transfer switch to your home. If you have questions before you order, our team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eGenerac Next-Gen 10kW Home Standby Generator Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7257 (generator only), 7321 (with transfer switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG0072570, G0073210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Capacity (LP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Capacity (NG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Maximum Load Current, 240V (LP \/ NG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 \/ 38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Line Circuit Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGenerac G-Force 400 Series, 1 cylinder, 459cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompression Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Capacity With Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.4 qt (1.3 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Zone 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCellular (standard), Wi-Fi and Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Requirement (Not Included)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V AGM Powersport Group BTX30L, 400 CCA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound at 23 ft, Normal Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound at 23 ft, Quiet-Test Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExercise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable 5 to 20 min (5 min default), weekly, bi-weekly or monthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Pressure at Inlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNG 3.5 to 7 in water column, LP 10 to 12 in water column\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNG Consumption, 1\/2 Load \/ Full Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 (2.77) \/ 132 (3.74) ft³\/hr (m³\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLP Consumption, 1\/2 Load \/ Full Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 (0.94) [3.55] \/ 58 (1.60) [6.07] ft³\/hr (gal\/hr) [L\/hr]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46.4 x 26.3 x 30.7 in (117.9 x 66.8 x 77.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e344 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum, Metro Gray, sound attenuated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2200, Southwest Research Institute (18 in to structure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 years or 2,000 hours, limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A, NEMA 3R, 16 spaces \/ 24 circuits (breakers not included), 10,000 AIC, cETLus, 39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eGenerac Next-Gen 10kW Home Standby Generator Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10-28kw-air-cooled-home-standby-generator-owners-manual.pdf?v=1793844929\" title=\"Generac Next-Gen 10kW Home Standby Generator Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10kw-home-standby-generator-manual.jpg?v=1793844951\" alt=\"Generac Next-Gen 10kW Home Standby Generator Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eGenerac Next-Gen 10kW Home Standby Generator Spec Sheet\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10-18kw-home-standby-generator-spec-sheet.pdf?v=1793844928\" title=\"Generac Next-Gen 10kW Home Standby Generator Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10kw-home-standby-generator-spec-sheet.jpg?v=1793844951\" alt=\"Generac Next-Gen 10kW Home Standby Generator Spec Sheet\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eGenerac Next-Gen 10kW Home Standby Generator Installation Manual\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10-28kw-air-cooled-home-standby-generator-installation-manual.pdf?v=1793844929\" title=\"Generac Next-Gen 10kW Home Standby Generator Installation Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10kw-home-standby-generator-installation-manual.jpg?v=1793844951\" alt=\"Generac Next-Gen 10kW Home Standby Generator Installation Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eGenerac Next-Gen 10kW Home Standby Generator Transfer Switch Manual\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-100a-16-circuit-nema-3r-automatic-transfer-switch-owners-manual.pdf?v=1793844929\" title=\"Generac Next-Gen 10kW Home Standby Generator Transfer Switch Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10kw-home-standby-generator-transfer-switch-manual.jpg?v=1793844951\" alt=\"Generac Next-Gen 10kW Home Standby Generator Transfer Switch Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Generac","offers":[{"title":"No Transfer Switch","offer_id":67602541117689,"sku":"7257","price":3916.59,"currency_code":"USD","in_stock":true},{"title":"100A 16-Circuit Transfer Switch","offer_id":67602541150457,"sku":"7321","price":4583.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/generac-next-gen-10kw-home-standby-generator-in-its-metro-gray-aluminum-enclosure.jpg?v=1793844951","url":"https:\/\/outboundpower.com\/products\/generac-next-gen-10kw-home-standby-generator-air-cooled-cellular-bluetooth-wifi-enabled","provider":"Outbound Power","version":"1.0","type":"link"}