{"product_id":"renogy-10a-16a-32a-50a-63a-1p-dc-miniature-circuit-breaker","title":"Renogy 10A\/16A\/32A\/50A\/63A 1P DC Miniature Circuit Breaker","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-1p-dc-miniature-circuit-breaker-with-a-gray-body-green-toggle-and-250v-rating-label.jpg\" alt=\"Renogy 1P DC Miniature Circuit Breaker with a gray body, green toggle and 250V rating label\" width=\"566\" height=\"859\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Renogy 10A\/16A\/32A\/50A\/63A 1P DC Miniature Circuit Breaker Protects Your DC Wiring and Resets After a Trip\u003c\/h2\u003e\n\u003cp\u003eThe Renogy 10A\/16A\/32A\/50A\/63A 1P DC Miniature Circuit Breaker is a single pole DIN rail breaker rated for 250V. It guards DC circuits against overloads and short circuits. When it detects a fault, it switches the circuit off to help protect wires and reduce the risk of fire.\u003c\/p\u003e\n\u003cp\u003eIt suits anyone adding circuit protection to a solar, battery or other DC system. Pick the current rating that matches your circuit, from 10A up to 63A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 10A\/16A\/32A\/50A\/63A 1P DC Miniature Circuit Breaker Features\u003c\/h3\u003e\n\u003ch4\u003eThermal and Magnetic Tripping\u003c\/h4\u003e\n\u003cp\u003eThe breaker uses both a thermal and a magnetic trip mechanism. Small overcurrents trip it after a delay, while a large surge trips it instantly. Renogy lists a rated instantaneous tripping current for each rating, and the breaker has a 6KA breaking capacity.\u003c\/p\u003e\n\u003ch4\u003eResets Instead of Replacing\u003c\/h4\u003e\n\u003cp\u003eAfter a trip, you reset the breaker and it is ready again. There is no fuse to replace. You can also switch it off by hand under its full rated load when you need to do electrical maintenance.\u003c\/p\u003e\n\u003ch4\u003eIndicator Window and Wiring Flexibility\u003c\/h4\u003e\n\u003cp\u003eA built-in indicator window shows the contact position at a glance. Renogy shows green for off and red for on. The breaker is built for reversible connection, so you can wire it in either direction, and it works with bidirectional current.\u003c\/p\u003e\n\u003ch4\u003eSnap-On DIN Rail Mounting\u003c\/h4\u003e\n\u003cp\u003eSnap the breaker into the slot of a standard DIN rail, then press the bottom until the buckle locks. To remove it, pull the buckle down. Terminals accept 14 AWG to 4 AWG wire.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCombiner and breaker boxes.\u003c\/strong\u003e Renogy says these breakers are often connected in combiner boxes, breaker boxes and home kits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMobile and off-grid power.\u003c\/strong\u003e Renogy shows RV, marine, camping, outdoor, cabin and truck uses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eController and inverter circuits.\u003c\/strong\u003e Size the breaker to the controller, inverter or DC device it protects.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eRenogy 1P Breaker Versus a Fuse\u003c\/h4\u003e\n\u003cp\u003eA fuse protects against overload and short circuit, but you must replace it after it opens. This breaker resets, and it can also be switched off by hand.\u003c\/p\u003e\n\u003ch4\u003eLower Ratings Versus Higher Ratings\u003c\/h4\u003e\n\u003cp\u003eAll five ratings share the same body, size and 250V rating. They differ in the current at which they trip, so pick the one closest to your circuit's needs.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eSizing the Breaker\u003c\/h4\u003e\n\u003cp\u003eFor a controller, inverter or other DC device, Renogy says to find the maximum continuous current by dividing watts by voltage, multiply by 1.25, and choose the breaker rated above and closest to that result. For a solar panel, multiply the short-circuit current by 1.25 twice and choose the same way.\u003c\/p\u003e\n\u003ch4\u003eTorque and Wire\u003c\/h4\u003e\n\u003cp\u003eRenogy recommends a terminal torque of 17.7 to 20.4 inch pounds (2 to 2.3 N·m). Use wire from 14 AWG to 4 AWG.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need a resettable protection device for a DC circuit\u003c\/li\u003e\n\u003cli\u003eYour enclosure uses a standard DIN rail\u003c\/li\u003e\n\u003cli\u003eYou want to see on or off status at a glance\u003c\/li\u003e\n\u003cli\u003eYour wire is between 14 AWG and 4 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat size wire will it accept?\u003c\/h4\u003e\n\u003cp\u003eThe breaker accepts wire from 14 AWG to 4 AWG.\u003c\/p\u003e\n\u003ch4\u003eWhat is the difference between a 1P and a 2P breaker?\u003c\/h4\u003e\n\u003cp\u003eA 1P breaker connects on the live wire only. Renogy says a 2P breaker connects on both the live and neutral wires and normally handles greater current and voltage.\u003c\/p\u003e\n\u003ch4\u003eWhere is the breaker often connected?\u003c\/h4\u003e\n\u003cp\u003eRenogy lists combiner boxes, breaker boxes and home kits.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1P DC Miniature Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach option includes one breaker in the current rating you choose.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eResettable DC Protection for Your System\u003c\/h3\u003e\n\u003cp\u003eThe Renogy 10A\/16A\/32A\/50A\/63A 1P DC Miniature Circuit Breaker gives your DC circuit protection you can reset. If you need help choosing a rating, the Outbound Power team is glad to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRenogy 10A\/16A\/32A\/50A\/63A 1P DC Miniature Circuit Breaker Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eRated Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frame Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10A Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e16A Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e32A Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50A Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e63A Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Non-Tripping Current (1 h or more)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5A \/ 16.8A \/ 33.6A \/ 52.5A \/ 66.15A for 10A \/ 16A \/ 32A \/ 50A \/ 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Tripping Current (under 1 h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13A \/ 20.8A \/ 41.6A \/ 65A \/ 81.9A for 10A \/ 16A \/ 32A \/ 50A \/ 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Instantaneous Tripping Current (under 0.1 s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60A \/ 96A \/ 192A \/ 300A \/ 378A for 10A \/ 16A \/ 32A \/ 50A \/ 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Short-Circuit Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUltimate Short-Circuit Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 times (under 125VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22°F to 158°F (-30°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 185°F (-40°C to 85°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDamp Heat Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMounting and Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG to 4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Terminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.7 to 20.4 inch pounds (2 to 2.3 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, RoHS, CB, TUV, SAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 x 3.0 x 0.7 in (82 x 76 x 18 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 oz (120 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial and Workmanship Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Renogy","offers":[{"title":"10A","offer_id":67614415257849,"sku":"SUNDCCB10MN1P-US","price":19.99,"currency_code":"USD","in_stock":true},{"title":"16A","offer_id":67614415290617,"sku":"SUNDCCB16MN1P-US","price":19.99,"currency_code":"USD","in_stock":false},{"title":"32A","offer_id":67614415323385,"sku":"SUNDCCB32MN1P-US","price":19.99,"currency_code":"USD","in_stock":true},{"title":"50A","offer_id":67614415356153,"sku":"SUNDCCB50MN1P-US","price":19.99,"currency_code":"USD","in_stock":false},{"title":"63A","offer_id":67614415388921,"sku":"SUNDCCB63MN1P-US","price":19.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-16a-1p-dc-miniature-circuit-breaker-in-gray-with-a-green-toggle-lever-and-rating-label-angled-front-view.jpg?v=1793973840","url":"https:\/\/outboundpower.com\/products\/renogy-10a-16a-32a-50a-63a-1p-dc-miniature-circuit-breaker","provider":"Outbound Power","version":"1.0","type":"link"}