{"product_id":"renogy-1ft-2ft-anl-fuse-cable-with-double-ring-terminals-for-3-8-in-lugs","title":"Renogy 1ft\/2ft ANL Fuse Cable with Double Ring Terminals for 3\/8 in Lugs","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/red-renogy-fuse-cable-with-double-ring-terminals-on-a-white-background.jpg\" alt=\"Red Renogy fuse cable with double ring terminals on a white background\" width=\"844\" height=\"901\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Renogy 1ft\/2ft ANL Fuse Cable with Double Ring Terminals for 3\/8 in Lugs Links Your ANL Fuse to Your Battery\u003c\/h2\u003e\n\u003cp\u003eThe Renogy 1ft\/2ft ANL Fuse Cable with Double Ring Terminals for 3\/8 in Lugs is a ready-made red cable with a ring terminal on each end. Renogy made it for connecting an ANL fuse to your batteries. One ring connects to the battery and the other connects to the ANL fuse.\u003c\/p\u003e\n\u003cp\u003eChoose 10 AWG, 8 AWG, 4 AWG or 2\/0 AWG to match your system. It is for anyone wiring a fused connection in a solar or battery setup who wants a finished cable instead of crimping their own.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 1ft\/2ft ANL Fuse Cable with Double Ring Terminals for 3\/8 in Lugs Features\u003c\/h3\u003e\n\u003ch4\u003eRing Terminals on Both Ends\u003c\/h4\u003e\n\u003cp\u003eEach cable has a ring terminal at both ends with a red insulating sleeve over the crimp. The rings let you bolt one end to the battery and the other end to the fuse.\u003c\/p\u003e\n\u003ch4\u003eTinned Copper Wire\u003c\/h4\u003e\n\u003cp\u003eRenogy's photo shows high-purity, oxygen-free tinned copper wire under a PVC insulated jacket. Tin plating is shown as an anti-oxidation feature for a long service life.\u003c\/p\u003e\n\u003ch4\u003eUV Resistant and TUV Tested\u003c\/h4\u003e\n\u003cp\u003eThe cable is UV resistant and TUV tested. Renogy says a TUV logo is printed every foot to show that the cable meets TUV standards for PV solar applications. Renogy's photo also shows UL and RoHS marks.\u003c\/p\u003e\n\u003ch4\u003eRated for Wide Temperatures\u003c\/h4\u003e\n\u003cp\u003eRenogy lists a temperature range of -40°F to +194°F. Its rated voltage is AC Uo\/U 0.6\/1 KV and DC 1.8KV.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCharge controller to battery.\u003c\/strong\u003e Renogy's wiring diagram puts a fused cable between a charge controller and the battery positive terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery to fuse connections.\u003c\/strong\u003e Use a short cable to link a battery terminal to an ANL fuse.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eFinished Fuse Cable Versus a Generic Cable You Crimp Yourself\u003c\/h4\u003e\n\u003cp\u003eThis cable arrives with ring terminals already attached, so you skip the crimping step. A generic cable gives you a custom length but needs lugs and a crimper.\u003c\/p\u003e\n\u003ch4\u003eThinner Versus Thicker Gauges\u003c\/h4\u003e\n\u003cp\u003eThe 10 AWG and 8 AWG options suit smaller circuits. The 4 AWG and 2\/0 AWG options use thicker wire for higher-current runs. Match the gauge to your circuit and to the fuse you use.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eChoosing the Gauge\u003c\/h4\u003e\n\u003cp\u003eRenogy offers several gauge sizes so you can get the right size for your system. Follow the cable size in the manual for your charge controller, inverter or battery.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need a short cable between a battery and an ANL fuse\u003c\/li\u003e\n\u003cli\u003eYou want ring terminals already attached\u003c\/li\u003e\n\u003cli\u003eYou want a UV resistant, TUV tested cable\u003c\/li\u003e\n\u003cli\u003eYour terminals take 3\/8 in lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat does this cable connect?\u003c\/h4\u003e\n\u003cp\u003eIt connects an ANL fuse to your batteries, with one ring for each end.\u003c\/p\u003e\n\u003ch4\u003eIs the fuse included?\u003c\/h4\u003e\n\u003cp\u003eNo. The cable is sold on its own, and you add the ANL fuse separately.\u003c\/p\u003e\n\u003ch4\u003eIs the cable UV resistant?\u003c\/h4\u003e\n\u003cp\u003eYes. Renogy lists UV resistance and TUV testing as key features.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Fuse Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach option includes one cable in the wire gauge you choose.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eA Finished Cable for Your Fused Connection\u003c\/h3\u003e\n\u003cp\u003eThe Renogy 1ft\/2ft ANL Fuse Cable with Double Ring Terminals for 3\/8 in Lugs gives you a ready-to-install link between your battery and fuse. If you need help picking a gauge, the Outbound Power team is glad to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRenogy 1ft\/2ft ANL Fuse Cable with Double Ring Terminals for 3\/8 in Lugs Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eWire Gauge Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e10 AWG, 8 AWG, 4 AWG, 2\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10 AWG Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8 AWG Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4 AWG Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC insulated, red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Uo\/U 0.6\/1 KV, DC 1.8KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to +194°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing terminal on each end, for 3\/8 in lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTesting and Marks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTUV tested, UV resistant, UL, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Renogy","offers":[{"title":"4 AWG","offer_id":67614424662265,"sku":"RNG-ANLFUSECB-4-US","price":16.99,"currency_code":"USD","in_stock":true},{"title":"8 AWG","offer_id":67614424695033,"sku":"RNG-ANLFUSECB-8-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"10 AWG","offer_id":67614424727801,"sku":"RNG-ANLFUSECB-10-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"2\/0 AWG","offer_id":67614424760569,"sku":"RPC0220BC-RD-US","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-anl-fuse-cable-in-red-curved-into-a-loop-with-a-ring-terminal-and-red-sleeve-on-each-end.jpg?v=1793974048","url":"https:\/\/outboundpower.com\/products\/renogy-1ft-2ft-anl-fuse-cable-with-double-ring-terminals-for-3-8-in-lugs","provider":"Outbound Power","version":"1.0","type":"link"}