{"product_id":"renogy-20a-30a-40a-100a-anl-fuse","title":"Renogy 20A\/30A\/40A\/100A ANL Fuse","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/angled-view-of-a-renogy-anl-fuse-showing-the-fuse-element-window-between-two-gold-colored-mounting-blades.jpg\" alt=\"Angled view of a Renogy ANL fuse showing the fuse element window between two gold colored mounting blades\" width=\"352\" height=\"234\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Renogy 20A\/30A\/40A\/100A ANL Fuse Protects Your Controller, Wire and Battery From Overcurrent\u003c\/h2\u003e\n\u003cp\u003eThe Renogy 20A\/30A\/40A\/100A ANL Fuse is a replaceable ANL fuse for DC systems operating below 72V. It is made of alloy and brass copper, and it has a clear window so you can see whether the fuse has opened.\u003c\/p\u003e\n\u003cp\u003eIt is for anyone fusing a charge controller, battery, inverter or the wires that connect them. Pick the current rating that matches your circuit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 20A\/30A\/40A\/100A ANL Fuse Features\u003c\/h3\u003e\n\u003ch4\u003eOvercurrent Protection for Your Equipment\u003c\/h4\u003e\n\u003cp\u003eRenogy says the ANL fuse protects your controller, wire and battery from overcurrent. The ratings are 20A, 30A, 40A and 100A, each for DC systems under 72V.\u003c\/p\u003e\n\u003ch4\u003eClear Window Shows Open Status\u003c\/h4\u003e\n\u003cp\u003eA visible window lets you identify an open fuse at a glance. Renogy also states the fuse is ignition protected, for use in RVs, boats and other closed environments.\u003c\/p\u003e\n\u003ch4\u003eCorrosion-Resistant Terminal Contacts\u003c\/h4\u003e\n\u003cp\u003eThe terminal contacts are gold and nickel plated for corrosion resistance. The fuse is RoHS compliant.\u003c\/p\u003e\n\u003ch4\u003eMade for the Renogy ANL Fuse Block\u003c\/h4\u003e\n\u003cp\u003eRenogy says the fuse is for use with its ANL fuse block, together with a clear protective non-conductive cover. The fuse can be replaced by itself when it blows.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCharge controller circuits.\u003c\/strong\u003e Fuse the cable between a controller and a battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInverter and battery wiring.\u003c\/strong\u003e Protect the connecting wires from overcurrent.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRVs and boats.\u003c\/strong\u003e Renogy says the ignition protection suits closed environments such as these.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eANL Fuse Versus a Circuit Breaker\u003c\/h4\u003e\n\u003cp\u003eA fuse is replaced after it opens. A breaker can be reset. An ANL fuse is a simple, compact choice when you want a replaceable protection part with a visible window.\u003c\/p\u003e\n\u003ch4\u003e20A Versus 30A Versus 40A Versus 100A\u003c\/h4\u003e\n\u003cp\u003eAll four ratings share a 72V voltage rating. They differ in the rated current and the interrupt capacity, so choose the one that matches your circuit.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eMatch the Rating Exactly\u003c\/h4\u003e\n\u003cp\u003eRenogy says to use fuses with current ratings that exactly match the system's rated current, and to follow the fuse size in the manual for your charge controller, battery charger or inverter. Never use a substitute such as copper wire. Replace a blown fuse with an identical model.\u003c\/p\u003e\n\u003ch4\u003eInstall With the Power Off\u003c\/h4\u003e\n\u003cp\u003eDisconnect all power before you replace a fuse, and wear insulating gloves. Renogy's manual lists 70.8 inch pounds (8 N·m) tightening torque for the nuts, with ring terminals sized for M8 studs. Fuse cables are sold separately.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYour DC system runs below 72V\u003c\/li\u003e\n\u003cli\u003eYou want a fuse you can check through a clear window\u003c\/li\u003e\n\u003cli\u003eYou are using a Renogy ANL fuse block\u003c\/li\u003e\n\u003cli\u003eYou need to replace a fuse without replacing the holder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eCan I replace the fuse by itself?\u003c\/h4\u003e\n\u003cp\u003eYes. Renogy says the fuse alone is replaceable. Replace the holder only if its terminals are damaged.\u003c\/p\u003e\n\u003ch4\u003eHow do I size an ANL fuse?\u003c\/h4\u003e\n\u003cp\u003eFollow the recommended fuse size in the manual for your charge controller, battery charger or inverter. You can also size it from the current going through the fuse.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a fuse cable?\u003c\/h4\u003e\n\u003cp\u003eNo. Renogy says you need to buy a fuse cable separately.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ANL Fuse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach option includes one fuse in the current rating you choose.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eA Replaceable Fuse for Your DC Wiring\u003c\/h3\u003e\n\u003cp\u003eThe Renogy 20A\/30A\/40A\/100A ANL Fuse gives your DC circuit a clear, replaceable point of protection. If you need help choosing a rating, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRenogy 20A\/30A\/40A\/100A ANL Fuse Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e72V or below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20A Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30A Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e40A Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100A Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e40A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlow Time at 220% of Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 seconds at maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlow Time at 250% of Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlow Time at 400% of Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 s to 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlloy and brass copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold and nickel plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Nut Tightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.8 in lbs (8 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRing Terminal Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8 studs (M8 to M10 acceptable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 20A\/30A\/40A\/100A ANL Fuse Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-20a-30a-40a-100a-anl-fuse-user-manual.pdf\" title=\"Renogy 20A\/30A\/40A\/100A ANL Fuse Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-20a-30a-40a-100a-anl-fuse-manual.jpg\" alt=\"Renogy 20A\/30A\/40A\/100A ANL Fuse Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Renogy","offers":[{"title":"20A","offer_id":67614421975289,"sku":"RNG-ANL-FUSE20-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"30A","offer_id":67614422008057,"sku":"RNG-ANL-FUSE30-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"40A","offer_id":67614422040825,"sku":"RNG-ANL-FUSE40-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"100A","offer_id":67614422073593,"sku":"RNG-ANL-FUSE100-US","price":33.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-anl-fuse-with-a-black-center-body-clear-open-status-window-and-gold-plated-terminal-blades.jpg?v=1793973966","url":"https:\/\/outboundpower.com\/products\/renogy-20a-30a-40a-100a-anl-fuse","provider":"Outbound Power","version":"1.0","type":"link"}