{"product_id":"renogy-20a-30a-40a-60a-80a-100a-200a-300a-400a-anl-fuse-set-with-fuse","title":"Renogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-anl-fuse-holder-with-a-clear-non-conductive-cover-brass-studs-and-an-anl-fuse-seen-from-the-front.jpg\" alt=\"Renogy ANL fuse holder with a clear non-conductive cover, brass studs and an ANL fuse seen from the front\" width=\"833\" height=\"782\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Renogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse Gives Your DC Circuit a Covered, Replaceable Fuse\u003c\/h2\u003e\n\u003cp\u003eThe Renogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse pairs an ANL fuse with a clear, non-conductive cover and a base with two 5\/16 inch (M8) studs. It is made for DC systems operating below 72V. Choose the current rating that matches your circuit.\u003c\/p\u003e\n\u003cp\u003eIt is for anyone fusing a charge controller, battery, inverter or the wires that connect them in a solar or battery system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse Features\u003c\/h3\u003e\n\u003ch4\u003eProtects Your Controller, Battery and Wires\u003c\/h4\u003e\n\u003cp\u003eRenogy says the set protects your charge controller, battery, inverter and connecting wires from overcurrent. The ANL fuse is made of high-quality alloy and brass copper.\u003c\/p\u003e\n\u003ch4\u003eClear Cover for Custom Installation\u003c\/h4\u003e\n\u003cp\u003eThe clear protective cover is non-conductive, and Renogy describes it as ideal for custom installation. The same cover is compatible with all of the fuse ratings.\u003c\/p\u003e\n\u003ch4\u003eIgnition Protection for Closed Spaces\u003c\/h4\u003e\n\u003cp\u003eRenogy says ignition protection guarantees safe use of the fuse in RVs, boats or any other closed environments. The fuse is also RoHS compliant.\u003c\/p\u003e\n\u003ch4\u003eFuse Replaces Without the Holder\u003c\/h4\u003e\n\u003cp\u003eWhen a fuse blows, you can replace the fuse alone. Replace the whole set only if the holder or terminals are damaged.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eController to battery wiring.\u003c\/strong\u003e Renogy's wiring diagram places the ANL fuse in the positive cable between a charge controller and a battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInverter circuits.\u003c\/strong\u003e Use the fuse set on the cable feeding an inverter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRVs and boats.\u003c\/strong\u003e The ignition protection suits closed environments like these.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eFuse Set Versus a Bare Fuse\u003c\/h4\u003e\n\u003cp\u003eA bare ANL fuse needs a holder. This set includes the base and the clear cover, so the studs and fuse are covered once it is installed.\u003c\/p\u003e\n\u003ch4\u003eLower Ratings Versus Higher Ratings\u003c\/h4\u003e\n\u003cp\u003eAll nine ratings share a voltage rating below 72V. Higher ratings carry more current and have a higher interrupt capacity, so match the rating to your circuit.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eChoosing the Fuse Size\u003c\/h4\u003e\n\u003cp\u003eFollow the fuse size in the manual for your charge controller, battery charger or inverter. Renogy's page also suggests a fuse rated at 1.25 times the maximum operating current, for example an 80A fuse for a 60A MPPT controller. Use a rating that matches your system's rated current and never install a mismatched fuse.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eDisconnect all power before installing or replacing a fuse, and wear insulating gloves. Use ring terminals sized for M8 studs and tighten the nuts to 70.8 inch pounds (8 N·m). Fuse cables are not included.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYour DC system runs below 72V\u003c\/li\u003e\n\u003cli\u003eYou want a covered fuse holder in one set\u003c\/li\u003e\n\u003cli\u003eYou have ring-terminal cables for 5\/16 inch studs\u003c\/li\u003e\n\u003cli\u003eYou want to replace a blown fuse without replacing the holder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat size are the posts?\u003c\/h4\u003e\n\u003cp\u003eThe posts are 5\/16 inch studs (M8). Renogy recommends ring lugs sized for M8 to M10.\u003c\/p\u003e\n\u003ch4\u003eDoes the set include a fuse cable?\u003c\/h4\u003e\n\u003cp\u003eNo. You need to buy a fuse cable separately.\u003c\/p\u003e\n\u003ch4\u003eCan I replace just the fuse?\u003c\/h4\u003e\n\u003cp\u003eYes. Renogy says the fuse can be removed and replaced on its own.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ANL Fuse\u003c\/li\u003e\n\u003cli\u003e1 x ANL Fuse Cover\u003c\/li\u003e\n\u003cli\u003e1 x ANL Fuse Base with Studs, Nuts and Washers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach option includes one set with the fuse rating you choose.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eA Covered, Replaceable Fuse for Your DC Wiring\u003c\/h3\u003e\n\u003cp\u003eThe Renogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse protects your DC circuit and keeps the connections covered. If you need help choosing a rating, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRenogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e72V or below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e40A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e60A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e80A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e200A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e300A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e400A Interrupt Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A, 30A, 40A, 60A, 80A, 100A, 200A, 300A, 400A (by option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlow Time at 220% of Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 seconds at maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlow Time at 250% of Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlow Time at 400% of Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 s to 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlloy and brass copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClear, non-conductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePost Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16 in studs (M8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRing Terminal Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8 studs (M8 to M10 acceptable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Nut Tightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.8 in lbs (8 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.88 x 1.48 x 1.48 in (124 x 37.6 x 37.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial and Workmanship Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-20a-30a-40a-60a-80a-100a-200a-300a-400a-anl-fuse-set-with-fuse-user-manual.pdf\" title=\"Renogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-20a-30a-40a-60a-80a-100a-200a-300a-400a-anl-fuse-set-with-fuse-manual.jpg\" alt=\"Renogy 20A\/30A\/40A\/60A\/80A\/100A\/200A\/300A\/400A ANL Fuse Set with Fuse Manual\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Renogy","offers":[{"title":"20A","offer_id":67614423449849,"sku":"RNG-SET-ANL20-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"30A","offer_id":67614423482617,"sku":"RNG-SET-ANL30-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"40A","offer_id":67614423515385,"sku":"RNG-SET-ANL40-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"60A","offer_id":67614423548153,"sku":"RNG-SET-ANL60-US","price":12.99,"currency_code":"USD","in_stock":true},{"title":"100A","offer_id":67614423580921,"sku":"RNG-SET-ANL100-US","price":12.99,"currency_code":"USD","in_stock":false},{"title":"200A","offer_id":67614423613689,"sku":"RPD200ANL-SET-US","price":15.99,"currency_code":"USD","in_stock":true},{"title":"300A","offer_id":67614423646457,"sku":"RPD300ANL-SET-US","price":15.99,"currency_code":"USD","in_stock":true},{"title":"400A","offer_id":67614423679225,"sku":"RPD400ANL-SET-US","price":15.99,"currency_code":"USD","in_stock":true},{"title":"80A","offer_id":67614423711993,"sku":"RPD80ANL-SET-US","price":13.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-anl-fuse-set-with-a-clear-cover-over-a-black-anl-fuse-and-two-gold-colored-5-16-inch-terminal-studs-with-an-rohs-label.jpg?v=1793974013","url":"https:\/\/outboundpower.com\/products\/renogy-20a-30a-40a-60a-80a-100a-200a-300a-400a-anl-fuse-set-with-fuse","provider":"Outbound Power","version":"1.0","type":"link"}