{"product_id":"renogy-3-to-1-solar-branch-connectors-mmmf-fffm-pair","title":"Renogy 3 to 1 Solar Branch Connectors MMMF+FFFM Pair","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/pair-of-black-renogy-3-to-1-solar-branch-connectors-for-wiring-three-solar-panels-in-parallel.jpg\" alt=\"Pair of black Renogy 3 to 1 solar branch connectors for wiring three solar panels in parallel\" width=\"1239\" height=\"986\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Renogy 3 to 1 Solar Branch Connectors MMMF+FFFM Pair Joins Three Solar Panels in Parallel With No Extra Tools\u003c\/h2\u003e\n\u003cp\u003eThe Renogy 3 to 1 Solar Branch Connectors MMMF+FFFM Pair is a set of two branch connectors for wiring three solar panels in parallel. One connector has three male ends and one female end. The other has three female ends and one male end.\u003c\/p\u003e\n\u003cp\u003eIt is for solar owners who want to combine three panels into a single connection. Renogy says a rivet and lock join the cable, so assembly and disassembly need no extra tools.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 3 to 1 Solar Branch Connectors MMMF+FFFM Pair Features\u003c\/h3\u003e\n\u003ch4\u003eThree Panels Into One Run\u003c\/h4\u003e\n\u003cp\u003eThe pair is made for connecting three panels in parallel. The male-branch connector joins the positive or negative leads of the three panels, and the female-branch connector does the same for the opposite polarity.\u003c\/p\u003e\n\u003ch4\u003e50A Current and DC1000V Rating\u003c\/h4\u003e\n\u003cp\u003eRenogy lists a rated current of 50A and a maximum working voltage of DC1000V. Contact resistance is 5 mΩ or less.\u003c\/p\u003e\n\u003ch4\u003eIP67 Shell and UV Endurance\u003c\/h4\u003e\n\u003cp\u003eThe shell has an IP67 protection degree. Renogy says the connectors have high aging resistance and UV endurance, so they are weather-proof and can handle harsh environments. The flame class is UL94-V0 and the ambient temperature range is -40°C to +85°C.\u003c\/p\u003e\n\u003ch4\u003ePlug and Pull Without Tools\u003c\/h4\u003e\n\u003cp\u003eInsertion force is 50N or less and withdrawal force is 50N or more. A rivet and lock join the cable, so you can assemble or take apart the plugs without extra tools.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThree-panel parallel setups.\u003c\/strong\u003e Combine three panels into one output run to a charge controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutdoor installations.\u003c\/strong\u003e The IP67 shell and UV endurance suit roofs, frames and other exposed spots.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eBranch Connectors Versus Wiring Panels in Series\u003c\/h4\u003e\n\u003cp\u003eBranch connectors wire panels in parallel, which keeps voltage at the level of a single panel and adds the currents. Series wiring adds voltage instead. Pick the layout your controller and panels call for.\u003c\/p\u003e\n\u003ch4\u003eThree-to-One Versus \u003cspan style=\"white-space: nowrap;\"\u003eFour-to-One\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThis pair joins three panels. A four-to-one pair joins four panels, so match the connector to the number of panels in your array.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eCheck Your Current\u003c\/h4\u003e\n\u003cp\u003eThe pair is rated for 50A. With panels in parallel, the currents add together, so check that the combined current of your three panels stays within the rating.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou are wiring three solar panels in parallel\u003c\/li\u003e\n\u003cli\u003eYour panels use solar connectors\u003c\/li\u003e\n\u003cli\u003eYou want to assemble the connection without extra tools\u003c\/li\u003e\n\u003cli\u003eYour system stays under DC1000V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat does MMMF+FFFM mean?\u003c\/h4\u003e\n\u003cp\u003eOne connector has three male ends and one female end. The other has three female ends and one male end.\u003c\/p\u003e\n\u003ch4\u003eDo I need tools to assemble it?\u003c\/h4\u003e\n\u003cp\u003eNo. Renogy says a rivet and lock connect the cable and no extra tools are needed.\u003c\/p\u003e\n\u003ch4\u003eHow many panels does it connect?\u003c\/h4\u003e\n\u003cp\u003eThree panels in parallel.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3 to 1 Solar Branch Connectors MMMF+FFFM Pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pair includes two connectors, one male-branch and one \u003cspan style=\"white-space: nowrap;\"\u003efemale-branch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eA Clean Way to Join Three Panels\u003c\/h3\u003e\n\u003cp\u003eThe Renogy 3 to 1 Solar Branch Connectors MMMF+FFFM Pair combines three panels into one parallel connection. If you have questions about your panel layout, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRenogy 3 to 1 Solar Branch Connectors MMMF+FFFM Pair Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003e3 to 1, MMMF+FFFM pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Working Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mΩ or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion Force\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50N or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithdrawal Force\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50N or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL94-V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShell Protection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Renogy","offers":[{"title":"Default Title","offer_id":67614425284857,"sku":"RNG-CNCT-MC4Y-M-US","price":14.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-3-to-1-solar-branch-connectors-mmmf-fffm-pair-a-three-male-branch-connector-beside-a-three-female-branch-connector.jpg?v=1793974077","url":"https:\/\/outboundpower.com\/products\/renogy-3-to-1-solar-branch-connectors-mmmf-fffm-pair","provider":"Outbound Power","version":"1.0","type":"link"}