{"product_id":"renogy-5ft-6awg-anderson-adapter-cable-anderson-pp75-to-3-8-in-lugs","title":"Renogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/coiled-pair-of-red-and-black-5ft-6awg-renogy-adapter-cables-with-anderson-pp75-connectors-on-one-end-and-lugs-on-the-other.jpg\" alt=\"Coiled pair of red and black 5FT 6AWG Renogy adapter cables with Anderson PP75 connectors on one end and lugs on the other\" width=\"858\" height=\"972\" style=\"display: block; width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Renogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs Connects Your REGO DC-DC Charger to Your Batteries Quickly\u003c\/h2\u003e\n\u003cp\u003eThe Renogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs is a pair of 5-foot cables, one red and one black. One end of each cable has an Anderson PP75 connector. The other end has a 3\/8 in metal lug. Renogy designed it to connect the Renogy REGO DC-DC battery charger with your batteries.\u003c\/p\u003e\n\u003cp\u003eIt is made for anyone adding a REGO DC-DC charger to an existing starter battery and house battery setup. The PP75 plugs straight into the charger, so you only need to bolt the lugs to your battery terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRenogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs Features\u003c\/h3\u003e\n\u003ch4\u003eAnderson PP75 Plug for the REGO Charger\u003c\/h4\u003e\n\u003cp\u003eThe PP75 connector is compatible with the REGO battery charger. Renogy says the Anderson connectors cut installation time by 60% compared with traditional double-ended ring terminals.\u003c\/p\u003e\n\u003ch4\u003eLugs Ready for Your Batteries\u003c\/h4\u003e\n\u003cp\u003eEach cable ends in a 3\/8 in metal lug. Renogy's page also calls this a dedicated M8 battery ring, so the lugs are made for a battery terminal bolt.\u003c\/p\u003e\n\u003ch4\u003eLabeled and Color Coded\u003c\/h4\u003e\n\u003cp\u003eThe positive cable is red and the negative cable is black. Renogy adds positive and negative labels on both ends of the wires, which makes hookup easier to check.\u003c\/p\u003e\n\u003ch4\u003e6 AWG Tinned Copper Wire\u003c\/h4\u003e\n\u003cp\u003eThe wire is high-purity oxygen-free tinned copper in 6 AWG. The cable is rated for 105 A and 600 V, and it is UL1015 compliant.\u003c\/p\u003e\n\u003ch4\u003eBuilt for Rough Conditions\u003c\/h4\u003e\n\u003cp\u003eHeat-shrinkable tube insulates the cable. Renogy lists an IP66 rating with a waterproof design and an operating range of -40°C to 105°C (-104°F to 221°F). The cable passed a vibration test for connection stability.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRV and truck systems.\u003c\/strong\u003e Link a REGO DC-DC charger to a starter battery and a house battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMarine and outdoor setups.\u003c\/strong\u003e Renogy lists RV, marine, camping, outdoor, cabin and truck uses for this cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrading an existing solar system.\u003c\/strong\u003e Renogy designed the cable so you can add a REGO charger to a solar system you already have.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eAnderson Adapter Cable Versus Double-Ended Ring Terminal Cable\u003c\/h4\u003e\n\u003cp\u003eA cable with ring terminals on both ends has to be bolted at the charger as well. This adapter plugs into the charger with the Anderson connector and uses lugs only at the battery.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eCheck the Connector Match\u003c\/h4\u003e\n\u003cp\u003eThis cable has a PP75 connector on one end and 3\/8 in lugs on the other. Make sure your charger uses a PP75 connection and your battery terminals take 3\/8 in lugs. Renogy describes it for the REGO DC-DC charger.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou are adding a Renogy REGO DC-DC charger to your system\u003c\/li\u003e\n\u003cli\u003eYour batteries take 3\/8 in lugs\u003c\/li\u003e\n\u003cli\u003eYou want a plug-in connection at the charger\u003c\/li\u003e\n\u003cli\u003eYou want red and black cables labeled at both ends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWill a thicker wire charge my battery faster?\u003c\/h4\u003e\n\u003cp\u003eRenogy says wire gauge works like a bottleneck. A thicker wire does not charge faster, but it carries more current and does it over longer distances. A wire that is too thin can build up heat.\u003c\/p\u003e\n\u003ch4\u003eCan I replace a damaged terminal?\u003c\/h4\u003e\n\u003cp\u003eYes. Renogy says you can buy a replacement terminal with the same specifications. The ring lug is M8 size and the Anderson terminal is the PP75 specification.\u003c\/p\u003e\n\u003ch4\u003eHow long is the cable?\u003c\/h4\u003e\n\u003cp\u003eEach cable is 5 FT long.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Renogy 5FT 6AWG Anderson Adapter Cable (Pair)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eEasy REGO Charger Hookup With the Renogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs\u003c\/h3\u003e\n\u003cp\u003eThe Renogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs gives your REGO DC-DC charger a plug-in link to your batteries. If you have questions about fit for your setup, the Outbound Power team is glad to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRenogy 5FT 6AWG Anderson Adapter Cable Anderson PP75 to 3\/8 in Lugs Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eFit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003eRPC0506PR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRenogy REGO DC-DC battery charger to batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharger End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnderson PP75 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in metal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-purity oxygen-free tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL1015 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSize and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pair (red positive, black negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 105°C (-104°F to 221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat-shrinkable tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL and RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertified ISO 9001 facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial and Workmanship Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Renogy","offers":[{"title":"Default Title","offer_id":67614415683833,"sku":"RPC0506PR-75-US","price":28.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/renogy-5ft-6awg-anderson-adapter-cable-anderson-pp75-to-3-8-in-lugs-coiled-red-and-black-cables-with-pp75-plugs-and-ring-lugs.jpg?v=1793973857","url":"https:\/\/outboundpower.com\/products\/renogy-5ft-6awg-anderson-adapter-cable-anderson-pp75-to-3-8-in-lugs","provider":"Outbound Power","version":"1.0","type":"link"}