{"product_id":"rich-solar-nova-max-3k-2026-3000w-24v-off-grid-hybrid-solar-inverter","title":"Rich Solar NOVA MAX 3K 2026 3000W 24V Off-Grid Hybrid Solar Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-2026-3000w-24v-off-grid-hybrid-solar-inverter-on-a-white-background.jpg\" alt=\"Rich Solar NOVA MAX 3K 2026 3000W 24V off-grid hybrid solar inverter on a white background\" width=\"1238\" height=\"1779\" style=\"display: block; width: 100%; max-width: 1238px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Rich Solar NOVA MAX 3K 2026 Hybrid Inverter Runs a 24V System on Solar, Battery, Shore or Generator Power With 3000W of Pure Sine Output\u003c\/h2\u003e\n\u003cp\u003eThe Rich Solar NOVA MAX 3K 2026 (model RS-H3024X) is an off-grid hybrid inverter for 24V battery systems. One wall-mounted unit holds a 3,000W pure sine wave inverter with a 6,000W surge, an 80A MPPT solar charge controller and an AC battery charger, so solar, a battery bank, utility power and a generator all work through the same box.\u003c\/p\u003e\n\u003cp\u003eRich Solar builds it for RVs, campers, vans, trailers, boats, cabins and solar home systems. Built-in Wi-Fi lets you monitor and control the system from an app, and up to nine units can run in parallel for single-phase, split-phase or three-phase power when your needs grow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3\u003eRich Solar NOVA MAX 3K 2026 Hybrid Inverter Features\u003c\/h3\u003e\n\u003ch4\u003e3000W of Clean Power With a 6000W Surge\u003c\/h4\u003e\n\u003cp\u003eThe inverter delivers 3,000W (3,000VA) at 120VAC ±5% and 50Hz or 60Hz, with harmonic distortion under 5% on linear loads and up to 91% efficiency in inverter mode. A 6,000W surge for 5 seconds helps start motors and compressors. Rich Solar says the pure sine output is safe for sensitive electronics and household appliances. The manual also lets you set the output to 110V or 127V.\u003c\/p\u003e\n\u003ch4\u003e80A MPPT Solar Charging Up to 3000W\u003c\/h4\u003e\n\u003cp\u003eThe built-in MPPT charger accepts up to 3,000W of solar with an MPPT range of 90V to 230V DC, a 250V DC maximum open-circuit voltage and a 22A maximum input current. Charging starts at 80V ±5V. Solar and utility charging together reach 80A, and you set the total from 10A to 80A in 10A steps.\u003c\/p\u003e\n\u003ch4\u003eThree Charging Modes and Three Output Modes\u003c\/h4\u003e\n\u003cp\u003eChoose Solar First, where utility charges the battery only when solar isn't available; Solar and Utility, where both charge at once for faster charging; or Only Solar. For loads, choose Utility First, Solar First, or SBU priority, which uses solar first, then the battery, and turns to utility only when the battery is low.\u003c\/p\u003e\n\u003ch4\u003eFast Transfer When Utility Power Drops\u003c\/h4\u003e\n\u003cp\u003eWhen utility power fails, the inverter switches loads to battery in 10ms in UPS mode or 20ms in appliance mode. UPS mode accepts 90V to 140V AC input for computers and other sensitive equipment, and appliance mode accepts 80V to 140V. When AC power returns, the unit restarts automatically with no manual reset.\u003c\/p\u003e\n\u003ch4\u003eWi-Fi App Monitoring and a Detailed LCD\u003c\/h4\u003e\n\u003cp\u003eBuilt-in Wi-Fi app monitoring lets you track status and change settings remotely. The LCD shows battery type, battery voltage and charging status, grid voltage and frequency, output voltage, current and power, and PV voltage, current and power. It also keeps a real-time clock and records daily, monthly, yearly and total generated energy along with fault codes. Communication options are Wi-Fi, RS232, RS485 and CAN.\u003c\/p\u003e\n\u003ch4\u003eLead-Acid and Lithium Batteries With BMS Communication\u003c\/h4\u003e\n\u003cp\u003eThe charger works with AGM, gel, flooded and lithium batteries. Bulk voltage is 29.2V for flooded and 28.8V for AGM or gel, float is 27.6V, and overcharge protection is set at 33V. A BMS port supports lithium battery communication. Rich Solar adds a cold start function, with a 23V cold start voltage, and battery equalization to improve reliability and extend battery life.\u003c\/p\u003e\n\u003ch4\u003eParallel Expansion Up to Nine Units\u003c\/h4\u003e\n\u003cp\u003eRich Solar rates the NOVA MAX 3K 2026 for parallel operation with up to nine units. The manual lists up to 27kW in single phase, with up to seven units on one phase of a three-phase system or eight on one phase of a split-phase system. Current sharing and parallel communication ports are on the bottom panel.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRVs and travel trailers.\u003c\/strong\u003e Charge a 24V house bank from roof solar and campground shore power, then run 120V appliances when you're parked \u003cspan style=\"white-space: nowrap;\"\u003eoff-grid.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMarine and boats.\u003c\/strong\u003e Combine solar and dock power to keep house batteries charged and AC loads running.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid cabins.\u003c\/strong\u003e Use SBU priority so solar and the battery carry the load, with a generator on the AC input as backup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar home systems.\u003c\/strong\u003e Start with one unit, then add more in parallel for more power or split-phase output.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eNOVA MAX 3K 2026 Versus Separate Components\u003c\/h4\u003e\n\u003cp\u003eA system built from a standalone inverter, a separate MPPT controller, an AC battery charger and a way to switch between sources means more parts to wire, mount and set up. The NOVA MAX 3K 2026 handles all of those jobs in one case, with one display, one app connection and one set of charging and output priorities.\u003c\/p\u003e\n\u003ch4\u003eNOVA MAX 3K 2026 Versus a Modified Sine Inverter\u003c\/h4\u003e\n\u003cp\u003eA modified sine inverter can run simple loads but isn't suited to every device. The NOVA MAX 3K 2026 produces pure sine wave output for sensitive electronics and household appliances, and it adds solar charging, AC charging and fast transfer that a basic inverter lacks.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eBattery, Cable and Breaker Sizing\u003c\/h4\u003e\n\u003cp\u003eThis model runs on a 24V battery bank, and the manual suggests at least 200Ah of capacity. It calls for 1\/0 AWG battery cable sized for a typical current of 145A, with a separate DC over-current protector between the battery and the inverter. The manual recommends a 150A, 40V DC battery breaker per inverter, a separate 50A AC input breaker, 8 AWG AC wiring and 12 AWG PV wiring. Install a DC breaker between the panels and the inverter, add a surge protection device rated 500V, and keep the array's open-circuit voltage under 250V.\u003c\/p\u003e\n\u003ch4\u003eMounting and Installation\u003c\/h4\u003e\n\u003cp\u003eMount the inverter vertically on concrete or another non-combustible surface, at eye level, with three M4 or M5 screws. Leave about 7.9 in (20 cm) at the sides and 19.7 in (50 cm) above and below for cooling. Rich Solar rates operation from 14°F to 104°F. For parallel systems, every inverter must share the same battery bank, and battery cables should all be the same length.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou have or plan a 24V battery bank\u003c\/li\u003e\n\u003cli\u003eYour loads stay under 3,000W running and 6,000W at \u003cspan style=\"white-space: nowrap;\"\u003estart-up\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eYou want Wi-Fi monitoring from your phone\u003c\/li\u003e\n\u003cli\u003eYou may add inverters in parallel later\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eCan I Use Lithium Batteries?\u003c\/h4\u003e\n\u003cp\u003eYes. Rich Solar lists AGM, gel, flooded and lithium batteries, and the BMS port supports lithium battery communication. The manual recommends a dedicated communication cable for this connection.\u003c\/p\u003e\n\u003ch4\u003eHow Much Solar Can I Connect?\u003c\/h4\u003e\n\u003cp\u003eUp to 3,000W. Keep each string inside the 90V to 230V MPPT range, under 250V open-circuit voltage, and at no more than 22A.\u003c\/p\u003e\n\u003ch4\u003eCan It Run an Air Conditioner?\u003c\/h4\u003e\n\u003cp\u003eThe manual lists air conditioners and refrigerators among the motor loads it can power, within the 3,000W rating and 6,000W surge. It cautions that an air conditioner needs 2 to 3 minutes before it restarts, so check whether yours has a time-delay function.\u003c\/p\u003e\n\u003ch4\u003eCan I Build Split-Phase Power With It?\u003c\/h4\u003e\n\u003cp\u003eYes, with more than one unit. The manual covers split-phase and three-phase systems with up to nine inverters, set up from the LCD on each unit.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Rich Solar NOVA MAX 3K 2026 Hybrid Inverter \u003cspan style=\"white-space: nowrap;\"\u003e(RS-H3024X)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 x Communication Cable\u003c\/li\u003e\n\u003cli\u003e1 x Software CD\u003c\/li\u003e\n\u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eFlexible 24V Power That Can Grow With You\u003c\/h3\u003e\n\u003cp\u003eThe Rich Solar NOVA MAX 3K 2026 Hybrid Inverter gives a 24V system 3,000W of pure sine power, an 80A MPPT solar charger, AC charging, Wi-Fi monitoring and room to expand in parallel. If you'd like help sizing the array, battery bank or parallel setup, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRich Solar NOVA MAX 3K 2026 3000W 24V Off-Grid Hybrid Solar Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003eRS-H3024X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000W (3000VA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000W for 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V, 120V (default), 127V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100ms at 205% load, 5s at 150% load, 10s at 110% to 150% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Priority Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUtility First, Solar First, SBU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSolar Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharger Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum PV Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum PV Open Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPPT Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90VDC to 230VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum PV Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Start-Up Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80VDC ±5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eAC Input and Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (UPS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90VAC to 140VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Appliance)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80VAC to 140VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum AC Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz (auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10ms (UPS), 20ms (appliance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Mode Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Utility Charge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Charge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A (utility + solar), set from 10A to 80A in 10A steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharger Source Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolar First, Solar and Utility (default), Only Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Battery Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAGM, gel, flooded, lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Algorithm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step (bulk, absorption, float)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBulk Charging Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.2VDC flooded, 28.8VDC AGM \/ gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloat Charging Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercharge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Cold Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Equalization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow DC Cut-Off Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-configurable (default 22.0V under 20% load, 20.4V at 20% to 50%, 19.2V at 50% and above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200Ah minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Battery Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG, 145A typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Battery Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150A \/ 40VDC per inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMonitoring and Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD with 4 function buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWi-Fi, RS232, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApp Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS port, communication port, current sharing port, parallel communication port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Parallel Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units, 27kW \/ 27kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThree Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units, max 7 units on one phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSplit Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units, max 8 units on one phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.61 x 12.12 x 18.80 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 x 8 x 16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart temperature-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5°F to 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, concrete or other non-combustible surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended AC Input Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eRich Solar NOVA MAX 3K 2026 3000W 24V Off-Grid Hybrid Solar Inverter Manuals and Documents\u003c\/h3\u003e\n\u003ch4\u003eRich Solar NOVA MAX 3K 2026 (RS-H3024X) User Manual\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-2026-rs-h3024x-user-manual.pdf\" title=\"Rich Solar NOVA MAX 3K 2026 (RS-H3024X) User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-2026-rs-h3024x-user-manual-for-the-rich-solar-nova-max-3k-2026-3000w-24v-off-grid-hybrid-solar-inverter.jpg\" alt=\"Rich Solar NOVA MAX 3K 2026 (RS-H3024X) User Manual for the Rich Solar NOVA MAX 3K 2026 3000W 24V Off-Grid Hybrid Solar Inverter\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch4\u003eRich Solar NOVA MAX 3K 2026 (RS-H3024X) Specification Sheet\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-2026-rs-h3024x-specification-sheet.pdf\" title=\"Rich Solar NOVA MAX 3K 2026 (RS-H3024X) Specification Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-2026-rs-h3024x-specification-sheet-for-the-rich-solar-nova-max-3k-2026-3000w-24v-off-grid-hybrid-solar-inverter.jpg\" alt=\"Rich Solar NOVA MAX 3K 2026 (RS-H3024X) Specification Sheet for the Rich Solar NOVA MAX 3K 2026 3000W 24V Off-Grid Hybrid Solar Inverter\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Rich Solar","offers":[{"title":"Default Title","offer_id":67698559910137,"sku":"RS-H3024X","price":799.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-2026-hybrid-inverter-front-view-of-the-gray-and-black-case-with-color-lcd-and-four-buttons.jpg?v=1794611804","url":"https:\/\/outboundpower.com\/products\/rich-solar-nova-max-3k-2026-3000w-24v-off-grid-hybrid-solar-inverter","provider":"Outbound Power","version":"1.0","type":"link"}