{"product_id":"rich-solar-nova-max-3k-3000w-24v-off-grid-hybrid-solar-inverter","title":"Rich Solar NOVA MAX 3K 3000W 24V Off-Grid Hybrid Solar Inverter","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 32px; margin: 0 0 40px;\"\u003e\n\u003cdiv style=\"flex: 2 1 320px; min-width: 0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-3000w-24v-hybrid-solar-inverter-straight-on-front-view-on-a-white-background.jpg\" alt=\"Rich Solar NOVA MAX 3K 3000W 24V hybrid solar inverter, straight-on front view on a white background\" width=\"1285\" height=\"1800\" style=\"display: block; width: 100%; max-width: 1285px; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 3 1 320px; min-width: 0; text-wrap: pretty;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eThe Rich Solar NOVA MAX 3K Hybrid Inverter Puts a 3000W Pure Sine Inverter, an 80A MPPT Solar Charger and a Battery Charger in One 24V Unit\u003c\/h2\u003e\n\u003cp\u003eThe Rich Solar NOVA MAX 3K (model RS-H3024) is an off-grid hybrid inverter for 24V battery systems. The case and the manual label it NOVA 3K24. It combines a 3,000W pure sine wave inverter, an 80A MPPT solar charge controller and an AC battery charger, so solar panels, a battery bank and utility or generator power all connect to one wall-mounted unit.\u003c\/p\u003e\n\u003cp\u003eRich Solar builds it for RVs, trailers, campers, vans, trucks, boats, cabins and other off-grid systems. It accepts up to 3,000W of solar at up to 250V open-circuit voltage, delivers a 6,000W surge for 5 seconds, and moves loads to battery power in 10ms in UPS mode or 20ms in appliance mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Model.\u003c\/strong\u003e Rich Solar now offers the \u003ca href=\"\/products\/rich-solar-nova-max-3k-2026-3000w-24v-off-grid-hybrid-solar-inverter\"\u003eRich Solar NOVA MAX 3K 2026 3000W 24V Off-Grid Hybrid Solar Inverter\u003c\/a\u003e as the current version of this inverter.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eRich Solar NOVA MAX 3K Hybrid Inverter Features\u003c\/h3\u003e\n\u003ch4\u003e3000W of Pure Sine Power With a 6000W Surge\u003c\/h4\u003e\n\u003cp\u003eThe inverter supplies 3,000W (3kVA) continuously at 120VAC ±5% and 60Hz or 50Hz, with 91% peak efficiency and harmonic distortion under 5% on linear loads. Surge capacity is twice the rated power for 5 seconds, which helps motors and compressors start. The manual says it can run motor-type appliances such as fans, refrigerators and air conditioners. The output can also be set to 110V or 127V from the LCD.\u003c\/p\u003e\n\u003ch4\u003eBuilt-In 80A MPPT Solar Charger\u003c\/h4\u003e\n\u003cp\u003eOne MPPT tracker handles up to 3,000W of solar. The MPPT range is 90V to 230V DC, maximum open-circuit voltage is 250V DC, and maximum input current is 22A. Charging starts at 80V ±5V.\u003c\/p\u003e\n\u003ch4\u003eCharging and Output Priorities You Choose\u003c\/h4\u003e\n\u003cp\u003eThree charger modes decide where battery charging comes from: Solar First, Solar and Utility (the default), or Only Solar. Three output modes decide what powers your loads: Utility First, Solar First, or SBU, which uses solar, then battery, then utility. Total charging current from solar and utility together is adjustable from 10A to 80A in 10A steps, and the utility share has its own limit.\u003c\/p\u003e\n\u003ch4\u003eLead-Acid and Lithium Battery Support\u003c\/h4\u003e\n\u003cp\u003eThe charger uses a 3-step profile. Bulk voltage is 29.2V for flooded batteries and 28.8V for AGM or gel, float is 27.6V, and overcharge protection trips at 33V. A user-defined setting lets you enter your own bulk, float and low DC cut-off voltages. The manual also lists lithium settings, including CAN and RS485 protocol options, that set charge values automatically. Battery equalization is available for flooded and user-defined batteries.\u003c\/p\u003e\n\u003ch4\u003eLCD Control, PC Monitoring and Auto Restart\u003c\/h4\u003e\n\u003cp\u003eAn LCD with four buttons and three LEDs shows input and output voltage, frequency, PV voltage, charging current, battery voltage and load. Settings are made from the same panel. The included communication cable and software CD connect the inverter to a computer for monitoring. When utility power returns, the unit restarts on its own, and the manual lists a cold start function with a 23.0V DC cold start voltage.\u003c\/p\u003e\n\u003ch4\u003eProtection and Parallel Ports\u003c\/h4\u003e\n\u003cp\u003eBuilt-in protection covers overload, over-temperature and output short circuits. The low DC cut-off moves with load, from 22.0V under 20% load down to 19.2V at 50% load and above, and the high DC cut-off is 33V. A 120VAC input breaker sits on the bottom panel next to parallel connection ports. The manual's parallel appendix covers up to nine units in single phase, for up to 27kW.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRVs, trailers and campers.\u003c\/strong\u003e Charge a 24V house bank from roof solar, plug into shore power or a generator at camp, and run 120V appliances from one unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVans, trucks and overland rigs.\u003c\/strong\u003e Pair solar with a 24V lithium or lead-acid bank to power tools, cooking appliances and electronics on the road.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoats.\u003c\/strong\u003e Rich Solar lists boats among its uses. Combine deck solar and dock power to keep house batteries charged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid cabins.\u003c\/strong\u003e Set SBU priority so solar and the battery carry the loads, with a generator on the AC input as backup.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eNOVA MAX 3K Versus Separate Components\u003c\/h4\u003e\n\u003cp\u003eA system built from separate parts needs an inverter, a solar charge controller, an AC battery charger and a way to switch between sources, each wired and set up on its own. The NOVA MAX 3K puts all four jobs in one case with one display and one set of priority settings.\u003c\/p\u003e\n\u003ch4\u003eNOVA MAX 3K Versus a Modified Sine Inverter\u003c\/h4\u003e\n\u003cp\u003eA modified sine inverter can run simple loads, but its stepped output isn't suited to every device. The NOVA MAX 3K produces pure sine wave output, which Rich Solar says is safe for sensitive electronics, and it adds solar and AC charging that a basic inverter lacks.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eBattery, Cable and Breaker Sizing\u003c\/h4\u003e\n\u003cp\u003eThis model runs on a 24V battery bank, and the manual suggests at least 200Ah of capacity. It calls for 1\/0 AWG battery cable with ring terminals, sized for a typical current of 145A, plus a separate DC over-current protector between the battery and the inverter. The manual recommends a 50A AC breaker on the input, 8 AWG AC wiring and 12 AWG PV wiring. Install a DC breaker between the panels and the inverter and a surge protection device rated 500V. Keep the array's open-circuit voltage under 250V and above the minimum battery voltage.\u003c\/p\u003e\n\u003ch4\u003eMounting and Installation\u003c\/h4\u003e\n\u003cp\u003eMount the inverter vertically on concrete or another non-combustible surface, at eye level so the display is easy to read, using three M4 or M5 screws. Leave about 7.9 in (20 cm) at the sides and 19.7 in (50 cm) above and below for cooling. Rich Solar rates operation from 14°F to 104°F. The manual says only qualified personnel should install it, and all wiring should be done with the DC and AC sources disconnected.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou have or plan a 24V battery bank\u003c\/li\u003e\n\u003cli\u003eYour loads stay under 3,000W running and 6,000W at \u003cspan style=\"white-space: nowrap;\"\u003estart-up\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eYou want up to 3,000W of solar wired in the 90V to 230V range\u003c\/li\u003e\n\u003cli\u003eYou want solar, shore and generator charging in one unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eCan I Use Lithium Batteries With It?\u003c\/h4\u003e\n\u003cp\u003eYes. Rich Solar says it supports lead-acid and lithium batteries. The manual lists lithium settings that set charge values automatically, and a BMS port carries RS232, RS485 and CAN signals. The manual recommends buying a dedicated communication cable for lithium battery communication.\u003c\/p\u003e\n\u003ch4\u003eHow Much Solar Can I Connect?\u003c\/h4\u003e\n\u003cp\u003eUp to 3,000W. Wire the panels so the string stays in the 90V to 230V MPPT range, never exceeds 250V open-circuit voltage, and draws no more than 22A.\u003c\/p\u003e\n\u003ch4\u003eCan It Run an Air Conditioner?\u003c\/h4\u003e\n\u003cp\u003eThe manual lists air conditioners among the motor loads it can power, within the 3,000W rating and 6,000W surge. It also cautions that an air conditioner needs 2 to 3 minutes before it restarts, so check whether yours has a time-delay function before you install.\u003c\/p\u003e\n\u003ch4\u003eDoes It Work With a Generator?\u003c\/h4\u003e\n\u003cp\u003eYes. The AC input accepts utility or generator power at 120V nominal. Appliance mode accepts 80V to 140V and UPS mode accepts 90V to 140V. If a generator's power isn't accepted, the manual suggests checking this setting.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Rich Solar NOVA MAX 3K Hybrid Inverter \u003cspan style=\"white-space: nowrap;\"\u003e(RS-H3024)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 x Communication Cable\u003c\/li\u003e\n\u003cli\u003e1 x Software CD\u003c\/li\u003e\n\u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eSolar, Shore and Generator Power for Your 24V System\u003c\/h3\u003e\n\u003cp\u003eThe Rich Solar NOVA MAX 3K Hybrid Inverter gives a 24V system 3,000W of pure sine power, an 80A MPPT solar charger, AC charging and flexible priority settings in one wall-mounted unit. If you'd like help sizing the array, battery bank or cables, the Outbound Power team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eRich Solar NOVA MAX 3K 3000W 24V Off-Grid Hybrid Solar Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003eRS-H3024 (NOVA 3K24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInverter Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000W (3kVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000W for 5 seconds (2x rated power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V, 120V (default), 127V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60Hz (default) or 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% linear load, \u0026lt;10% non-linear load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100ms at 205% load, 5s at 150% load, 10s at 110% to 150% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Short Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker (line mode), electronic (battery mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Priority Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUtility First, Solar First, SBU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eSolar Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharger Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPP Trackers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated PV Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum PV Open Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPPT Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90VDC to 230VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum PV Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Start-Up Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80V ±5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eAC Input and Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSinusoidal (utility or generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (UPS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90VAC to 140VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Appliances)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80VAC to 140VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum AC Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz (auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10ms (UPS), 20ms (appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Mode Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Charging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Charging Current (Solar + Utility)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10A to 80A, adjustable in 10A steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharger Source Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolar First, Solar and Utility (default), Only Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAGM (default), flooded, user-defined, lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Algorithm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-step (bulk, absorption, float)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBulk Charging Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.2VDC flooded, 28.8VDC AGM \/ gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloat Charging Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercharge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCold Start Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.0VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow DC Cut-Off Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0V (\u0026lt;20% load), 20.4V (20% to 50%), 19.2V (50% and above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh DC Cut-Off Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Equalization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (flooded and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuggested Battery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200Ah minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Battery Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0 AWG, 145A typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCommunication and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD with 4 buttons and 3 LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS (RS232, RS485, CAN), communication port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication cable and software CD included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units in single phase, 27kW (manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 x 12.1 x 18.8 in (142.4 x 307.8 x 477.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.5 lb (12 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14°F to 104°F (-10°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5°F to 140°F (-15°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, concrete or other non-combustible surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended AC Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePV Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eRich Solar NOVA MAX 3K 3000W 24V Off-Grid Hybrid Solar Inverter Manuals and Documents\u003c\/h3\u003e\n\u003ch4\u003eRich Solar NOVA MAX 3K (NOVA 3K24) User Manual\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-nova-3k24-user-manual.pdf\" title=\"Rich Solar NOVA MAX 3K (NOVA 3K24) User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-nova-3k24-user-manual-for-the-rich-solar-nova-max-3k-3000w-24v-off-grid-hybrid-solar-inverter.jpg\" alt=\"Rich Solar NOVA MAX 3K (NOVA 3K24) User Manual for the Rich Solar NOVA MAX 3K 3000W 24V Off-Grid Hybrid Solar Inverter\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch4\u003eRich Solar NOVA MAX 3K (NOVA 3K24) Specification Sheet\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-nova-3k24-specification-sheet.pdf\" title=\"Rich Solar NOVA MAX 3K (NOVA 3K24) Specification Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-nova-3k24-specification-sheet-for-the-rich-solar-nova-max-3k-3000w-24v-off-grid-hybrid-solar-inverter.jpg\" alt=\"Rich Solar NOVA MAX 3K (NOVA 3K24) Specification Sheet for the Rich Solar NOVA MAX 3K 3000W 24V Off-Grid Hybrid Solar Inverter\" width=\"100\" height=\"100\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Rich Solar","offers":[{"title":"Default Title","offer_id":67698557485305,"sku":"RS-H3024","price":799.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/rich-solar-nova-max-3k-hybrid-inverter-front-angle-view-of-the-gray-and-black-case-marked-nova-3k24-with-lcd-and-buttons.jpg?v=1794611713","url":"https:\/\/outboundpower.com\/products\/rich-solar-nova-max-3k-3000w-24v-off-grid-hybrid-solar-inverter","provider":"Outbound Power","version":"1.0","type":"link"}