{"product_id":"sol-ark-15k-2p","title":"Sol-Ark 15K-2P Hybrid Inverter System","description":"\u003ch2\u003eSol-Ark 15K-2P Hybrid Inverter System Gives You Flexible Power Management\u003c\/h2\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P Hybrid Inverter System is an all-in-one hybrid power system designed to manage energy between solar, batteries, the utility grid, loads, and a generator. It combines an inverter, charger controller, touchscreen display, and remote monitoring in one system, making it suitable for grid-tied, off-grid, and battery-backup solar applications. With up to 15,000W of continuous real power, three MPPT trackers, 48V battery operation, and support for both lithium and lead-acid battery technologies, it provides a flexible foundation for building a substantial energy system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSol-Ark 15K-2P Hybrid Inverter System Features\u003c\/h3\u003e\n\u003ch4\u003e15,000W Continuous Output For Substantial Power Demands\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P provides up to \u003cstrong\u003e15,000W of maximum continuous real power\u003c\/strong\u003e. That gives system designers a substantial amount of available AC output for applications that require more than a small portable power station can provide. When operating from batteries without PV input, the inverter provides up to 12,000W of continuous real power.\u003c\/p\u003e\n\u003cp\u003eFor off-grid operation, the system also provides peak apparent power of 24,000VA for 10 seconds and 30,000VA for 100 milliseconds at 240V. These figures can be useful when planning a system around loads with higher short-duration power demands.\u003c\/p\u003e\n\u003ch4\u003eMultiple Power Sources So You Can Manage Energy More Flexibly\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P is designed to manage power to and from \u003cstrong\u003esolar, batteries, the grid, loads, and a generator\u003c\/strong\u003e. Rather than functioning as a basic inverter alone, it brings several parts of a power system together in one platform.\u003c\/p\u003e\n\u003cp\u003eThe system supports grid-tied, off-grid, and battery-backup solar operation. Its programmable operating functions also include Grid Tied Mode, Meter Zero Mode, Time of Use, and Smart Load Mode.\u003c\/p\u003e\n\u003ch4\u003eThree MPPT Trackers For Flexible Solar Input\u003c\/h4\u003e\n\u003cp\u003eThe PV input section includes \u003cstrong\u003ethree maximum power point trackers\u003c\/strong\u003e, with two PV strings per MPPT. The system allows up to 19,500W of PV power at STC, with a nominal PV voltage range of 175–425V and a maximum input voltage of 500V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 MPPT trackers\u003c\/li\u003e\n\u003cli\u003e2 PV strings per MPPT\u003c\/li\u003e\n\u003cli\u003e19,500W maximum allowed PV power at STC\u003c\/li\u003e\n\u003cli\u003e26A maximum input current per MPPT\u003c\/li\u003e\n\u003cli\u003e19,200W maximum AC-coupled input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis gives customers and system designers more flexibility when planning the solar portion of the system, while the actual PV configuration should be confirmed against the complete system design and applicable requirements.\u003c\/p\u003e\n\u003ch4\u003e48V Battery Operation For Practical Energy Storage\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P operates with a \u003cstrong\u003e48V nominal DC battery voltage\u003c\/strong\u003e and supports both lithium and lead-acid battery technologies. Its stated battery operating voltage range is 43–63V, with a maximum battery charge and discharge current of 275A.\u003c\/p\u003e\n\u003cp\u003eThe charging controller uses a three-stage charging process with equalization. The system also includes an integrated current shunt for accurate state-of-charge percentage monitoring, automatic generator start, and communication with lithium batteries through CANBus and RS485.\u003c\/p\u003e\n\u003ch4\u003eFast Backup Transfer For Responsive Power Switching\u003c\/h4\u003e\n\u003cp\u003eThe specified backup transfer time is \u003cstrong\u003e5 milliseconds\u003c\/strong\u003e. The system also provides a maximum grid passthrough current of 200A. These specifications are important considerations when planning a backup power system where the transition between available power sources matters.\u003c\/p\u003e\n\u003ch4\u003eStackable Design For Larger System Configurations\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P can be connected in parallel with up to \u003cstrong\u003e12 units\u003c\/strong\u003e. This provides an expansion path for system designs that require more inverter capacity than a single unit can provide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eReal-World Applications For The Sol-Ark 15K-2P\u003c\/h3\u003e\n\u003ch4\u003eHome Backup Power For Greater Energy Resilience\u003c\/h4\u003e\n\u003cp\u003eThe system can serve as part of a residential battery-backup solar system, managing energy between solar generation, batteries, the grid, loads, and a generator. Its 15,000W continuous AC output provides considerably more capacity than compact portable power stations, making it appropriate for larger fixed power systems when the overall design calls for this level of capacity.\u003c\/p\u003e\n\u003ch4\u003eOff-Grid Solar Systems For Independent Power Planning\u003c\/h4\u003e\n\u003cp\u003eFor off-grid applications, the Sol-Ark 15K-2P can coordinate solar and battery energy while also providing generator integration. Its PV input capacity, battery management functions, and off-grid peak power specifications make it a system-level component rather than simply a standalone battery inverter.\u003c\/p\u003e\n\u003ch4\u003eSolar Systems With Grid Interaction For Energy Management\u003c\/h4\u003e\n\u003cp\u003eThe system supports Grid Tied Mode, Meter Zero Mode, and Time of Use operation. These functions allow the system to be configured around different approaches to managing solar, battery, and grid power. Specific operating behavior should be confirmed against the intended system design and applicable electrical requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHow The Sol-Ark 15K-2P Compares With Smaller Power Systems\u003c\/h3\u003e\n\u003cp\u003eA compact portable power station is designed around portability and relatively modest loads. The Sol-Ark 15K-2P serves a different purpose. It is a high-capacity hybrid inverter system intended to coordinate solar, batteries, grid power, loads, and generator input within a larger energy system.\u003c\/p\u003e\n\u003cp\u003eCompared with a basic inverter, the Sol-Ark 15K-2P combines inverter and charging functions with solar MPPT control, battery management features, monitoring, and multiple power-management modes. It can also be paralleled with additional units, providing a different approach to system expansion than simply selecting a larger standalone portable unit.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eIs The Sol-Ark 15K-2P Right For Your Power System\u003c\/h3\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P may be worth considering if you are planning a substantial solar and battery system rather than looking for a small plug-and-play power station. Its capabilities are especially relevant when the design needs to coordinate multiple energy sources and support significant AC loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis May Be A Good Fit If:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou are planning a grid-tied, off-grid, or battery-backup solar system.\u003c\/li\u003e\n\u003cli\u003eYou need up to 15,000W of continuous real AC power.\u003c\/li\u003e\n\u003cli\u003eYou want to manage solar, battery, grid, loads, and generator power through one hybrid system.\u003c\/li\u003e\n\u003cli\u003eYour battery design uses a 48V nominal battery system.\u003c\/li\u003e\n\u003cli\u003eYou want flexibility between lithium and lead-acid battery technologies.\u003c\/li\u003e\n\u003cli\u003eYour system may benefit from multiple MPPT trackers and substantial PV input capacity.\u003c\/li\u003e\n\u003cli\u003eYou are considering a system that can be expanded by paralleling multiple inverter units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore purchasing, confirm the battery configuration, PV design, electrical requirements, installation details, and other system-level considerations for your specific application.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCommon Questions About The Sol-Ark 15K-2P Hybrid Inverter System\u003c\/h3\u003e\n\u003ch4\u003eHow Much Power Does The Sol-Ark 15K-2P Provide?\u003c\/h4\u003e\n\u003cp\u003eThe system provides up to 15,000W of maximum continuous real power. When operating from batteries only with no PV input, the maximum continuous real power is 12,000W.\u003c\/p\u003e\n\u003ch4\u003eWhat Battery Voltage Does The Sol-Ark 15K-2P Use?\u003c\/h4\u003e\n\u003cp\u003eThe system uses a 48V nominal DC battery voltage and has a stated operating voltage range of 43–63V.\u003c\/p\u003e\n\u003ch4\u003eDoes The Sol-Ark 15K-2P Support Different Battery Types?\u003c\/h4\u003e\n\u003cp\u003eYes. The listed battery technologies are lithium and lead acid. The system also provides CANBus and RS485 communication to lithium batteries.\u003c\/p\u003e\n\u003ch4\u003eHow Much Solar Input Can The Sol-Ark 15K-2P Handle?\u003c\/h4\u003e\n\u003cp\u003eThe maximum allowed PV power at STC is 19,500W. The system has three MPPT trackers, two PV strings per MPPT, and a maximum PV input voltage of 500V.\u003c\/p\u003e\n\u003ch4\u003eCan Multiple Sol-Ark 15K-2P Units Be Used Together?\u003c\/h4\u003e\n\u003cp\u003eYes. The specifications state that the system is stackable, with up to 12 units capable of being connected in parallel.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 56.375px;\"\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%; height: 56.375px;\"\u003e\n\u003ch3\u003eSol-Ark 15K-2P Hybrid Inverter System Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Allowed PV Power (STC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e19,500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Nominal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e175–425V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Startup Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum PV Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Input Current Per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e26A (Self-Limiting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMPPT Trackers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Strings Per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum AC-Coupled Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e19,200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal AC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e120\/240V, 120\/208V, 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGrid Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50 \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Continuous Real Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e15,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e62.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Continuous Real Power (Batteries Only, No PV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e12,000W (50A @ 240V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePeak Apparent Power (10 Seconds, Off-Grid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e24,000VA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePeak Apparent Power (100ms, Off-Grid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e30,000VA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Output Fault Current (5 Seconds)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e94A With PV; 75A Batteries Only, No PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Output Fault Current (100ms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Grid Passthrough Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Factor Output Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e±0.9 Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBackup Transfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e5ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCEC Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e96.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eTransformerless DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStackable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eUp to 12 Units In Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Technologies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eLithium \/ Lead Acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal DC Battery Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Operating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e43–63V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50–9,900Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum Battery Charge \/ Discharge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e275A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCharging Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e3-Stage With Equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGrid To Battery Charging Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eExternal Temperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCurrent Shunt For State Of Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAutomatic Generator Start\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eLithium Battery Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eCANBus \u0026amp; RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e31.8 × 19.4 × 12 in (807 × 494 × 306 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e135 lb (61.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIP65 \/ NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e-25°C to 55°C; \u0026gt;45°C Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e\u0026lt;30 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eIdle Consumption (No Load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e90W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eWi-Fi \u0026amp; LAN Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandard Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e10 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV DC Disconnect Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGround Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Rapid Shutdown Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Arc Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Input Lightning Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePV String Input Reverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAC Output Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e200A, Integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Breaker \/ Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e200A × 2, Integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eDC Type II \/ AC Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eWhat’s Included \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Sol-Ark 15K-2P Hybrid Inverter System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe source information does not provide a separate accessories or package-content list. Confirm the exact contents of the selected product configuration before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eBuild Your Power System With Practical Planning\u003c\/h3\u003e\n\u003cp\u003eThe Sol-Ark 15K-2P Hybrid Inverter System is built for customers planning a serious solar and battery power system with multiple energy sources to manage. With 15,000W of continuous real power, 19,500W of maximum allowed PV input, three MPPT trackers, 48V battery operation, integrated monitoring, generator integration, and the ability to parallel up to 12 units, it offers a broad set of system-level capabilities in one platform.\u003c\/p\u003e\n\u003cp\u003eAt Outbound Power, we focus on helping customers select equipment based on the actual requirements of the power system—not simply a big number on a product page. Review your load requirements, solar array, battery configuration, and intended operating mode, then choose the Sol-Ark 15K-2P when its specifications align with your design.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSol-Ark 15K-2P Hybrid Inverter System Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_Manual.pdf?v=1790596597\" title=\"Sol-Ark 15K-2P Hybrid Inverter System Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_Manual_100x100.jpg?v=1790596570\" alt=\"Sol-Ark_15K-2P_Hybrid_Inverter_System_Manual\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ch3\u003eSol-Ark 15K-2P Hybrid Inverter System Spec Sheet\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_Spec_Sheet.pdf?v=1790596683\" title=\"Sol-Ark 15K-2P Hybrid Inverter System Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_Spec_Sheet_100x100.jpg?v=1790596668\" alt=\"Sol-Ark_15K-2P_Hybrid_Inverter_System_Spec_Sheet\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSol-Ark 15K-2P Hybrid Inverter System Brochure\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_Brochure.pdf?v=1790596901\" title=\"Sol-Ark 15K-2P Hybrid Inverter System Brochure\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_Brochure_100x100.jpg?v=1790596743\" alt=\"Sol-Ark_15K-2P_Hybrid_Inverter_System_Brochure\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sol-Ark","offers":[{"title":"Standard","offer_id":49118984405241,"sku":"SA-15K-2P","price":5750.0,"currency_code":"USD","in_stock":true},{"title":"EMP Hardened","offer_id":49118984438009,"sku":"SA-15K-2P-EMP","price":7750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_15K-2P_Hybrid_Inverter_System_-_product_image_1.png?v=1790606720","url":"https:\/\/outboundpower.com\/products\/sol-ark-15k-2p","provider":"Outbound Power","version":"1.0","type":"link"}