{"product_id":"sol-ark-5k-2p","title":"Sol-Ark 5K-2P Hybrid Inverter System","description":"\u003ch2\u003eSol-Ark 5K-2P Hybrid Inverter System Gives You Flexible 5,000W Power Control\u003c\/h2\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P Hybrid Inverter System is designed to manage solar, battery, utility, and generator power from one hybrid energy system. With 5,000W of continuous AC output, 120\/240V split-phase capability, integrated solar charge control, and support for grid-connected, off-grid, and battery backup operation, it gives homeowners and power-system planners a practical way to coordinate multiple energy sources. Remote monitoring, 2 MPPT trackers, and integrated protection features add useful control for backup and renewable energy applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSol-Ark 5K-2P Hybrid Inverter System Features\u003c\/h3\u003e\n\u003ch4\u003e5,000W Continuous Output For Everyday Backup Power\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P provides up to \u003cstrong\u003e5,000W of real power continuously\u003c\/strong\u003e, with a maximum output current of 20.8A. Its 120\/240V and 120\/208V AC output options allow the inverter to support different system configurations based on the power requirements of the installation.\u003c\/p\u003e\n\u003cp\u003eWhen operating off-grid, it can provide up to 16,000VA of peak apparent power for 10 seconds at 240V and up to 25,000VA for 100 milliseconds. That gives the system additional short-duration capacity when connected loads require a temporary surge.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eSolar Charge Control For Better Energy Management\u003c\/h4\u003e\n\u003cp\u003eWith integrated hybrid inverter and solar charge control functions, the Sol-Ark 5K-2P can manage solar input alongside battery and other available power sources. The system accepts up to \u003cstrong\u003e6,500W of PV power at STC\u003c\/strong\u003e and includes 2 MPP trackers with 2 PV strings per MPPT.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e6,500W maximum allowed PV power at STC\u003c\/li\u003e\n\u003cli\u003e175–425V rated MPPT operating voltage range\u003c\/li\u003e\n\u003cli\u003e150–500V MPPT voltage range\u003c\/li\u003e\n\u003cli\u003e125V startup voltage\u003c\/li\u003e\n\u003cli\u003e500V maximum input voltage\u003c\/li\u003e\n\u003cli\u003e10A maximum operating input current per MPPT, self-limiting\u003c\/li\u003e\n\u003cli\u003e9,600W maximum AC-coupled input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eBattery Management For Backup And Off-Grid Operation\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P supports \u003cstrong\u003e48V battery systems\u003c\/strong\u003e using lithium or lead-acid battery technologies. Its operating voltage range is 43–63V, with a maximum battery charge or discharge current of 120A. The charging controller uses a 3-stage design with equalization, while grid-to-battery charging efficiency is rated at 96.0%.\u003c\/p\u003e\n\u003cp\u003eThe system also includes an external battery temperature sensor and supports BMS communication through CANBus and RS485 MODBUS. Battery capacity is specified at 50–9900Ah, giving system designers a broad stated capacity range to work within.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eGrid And Generator Management So You Can Coordinate Multiple Power Sources\u003c\/h4\u003e\n\u003cp\u003eThis hybrid inverter is designed to manage solar, battery, utility, and generator power. It supports grid-connected, off-grid, and battery backup operating modes, helping create a system around the power sources available at the property or site.\u003c\/p\u003e\n\u003cp\u003eAn integrated \u003cstrong\u003e2-wire Automatic Generator Start\u003c\/strong\u003e function provides generator-start capability when used as part of an appropriate system configuration. The maximum grid passthrough current is 63A.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eFast Backup Transfer For Connected Loads\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P has a specified \u003cstrong\u003e4ms backup transfer time\u003c\/strong\u003e. For applications where backup power response matters, this provides a clearly defined transfer specification to consider when planning the system.\u003c\/p\u003e\n\u003cp\u003eThe inverter also offers an adjustable output power factor range of +\/- 0.9 and uses a transformerless DC-to-AC design.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eRemote Monitoring For Easier System Oversight\u003c\/h4\u003e\n\u003cp\u003ePower-system management does not have to mean standing next to the inverter all day. The Sol-Ark 5K-2P includes \u003cstrong\u003eWi-Fi and LAN hardware\u003c\/strong\u003e for communication and monitoring, providing remote monitoring capability for the system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eIntegrated Protection For A More Complete Power System\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P includes several integrated protection and control features. These features are designed into the system rather than requiring the product description to rely on vague safety claims.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated PV DC disconnect switch\u003c\/li\u003e\n\u003cli\u003eIntegrated ground fault detection\u003c\/li\u003e\n\u003cli\u003eIntegrated PV rapid shutdown control\u003c\/li\u003e\n\u003cli\u003eIntegrated PV arc fault detection\u003c\/li\u003e\n\u003cli\u003eIntegrated PV input lightning protection\u003c\/li\u003e\n\u003cli\u003eIntegrated PV string input reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eIntegrated 63A AC output breaker\u003c\/li\u003e\n\u003cli\u003eIntegrated 250A battery breaker and disconnect\u003c\/li\u003e\n\u003cli\u003eDC Type II and AC Type II surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eReal-World Applications For The Sol-Ark 5K-2P\u003c\/h3\u003e\n\u003ch4\u003eHome Backup Power For Essential Loads\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P can be used as part of a home energy system where solar generation, batteries, utility power, and generator power need to be coordinated. Its 5,000W continuous output and 120\/240V capability make it suited to planned backup-power applications where the system is designed around the property's electrical requirements.\u003c\/p\u003e\n\u003ch4\u003eOff-Grid Energy Systems For Remote Locations\u003c\/h4\u003e\n\u003cp\u003eFor off-grid applications, the inverter can combine solar and battery resources while also supporting generator power. Its 6,500W maximum allowed PV input and 48V battery architecture provide defined specifications for designing an off-grid energy system.\u003c\/p\u003e\n\u003ch4\u003eEmergency Preparedness For Extended Power Interruptions\u003c\/h4\u003e\n\u003cp\u003eWhen utility power is unavailable, a properly designed battery backup system can use the Sol-Ark 5K-2P to coordinate stored battery energy and available generation. The inverter's grid, battery, solar, and generator management capabilities make it relevant for preparedness-focused power systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHow The Sol-Ark 5K-2P Compares With Typical Alternatives\u003c\/h3\u003e\n\u003cp\u003eA smaller portable power station is generally designed around portability and simpler plug-and-use operation, while the Sol-Ark 5K-2P is a \u003cstrong\u003ehybrid inverter for a larger integrated energy system\u003c\/strong\u003e. It is designed to coordinate solar, batteries, utility power, and generator power rather than functioning simply as a standalone portable battery.\u003c\/p\u003e\n\u003cp\u003eCompared with a conventional generator-only backup approach, the Sol-Ark 5K-2P provides integrated solar and battery management in addition to generator support. It therefore makes sense when the goal is to coordinate multiple power sources instead of relying on a single generation method.\u003c\/p\u003e\n\u003cp\u003eIt is also different from a basic solar inverter because the system includes battery management and supports grid-connected, off-grid, and battery backup operating modes. The right choice depends on the overall system design, required output, battery configuration, solar array, and available power sources.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eIs The Sol-Ark 5K-2P Right For Your Power System\u003c\/h3\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P is worth considering when you need a hybrid inverter that can coordinate multiple energy sources and provide 5,000W of continuous AC output. It is particularly relevant for system planners working with 48V batteries, solar PV, utility power, and generator backup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis May Be A Good Fit If\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou need 5,000W of continuous AC output.\u003c\/li\u003e\n\u003cli\u003eYou are building a grid-connected, off-grid, or battery backup system.\u003c\/li\u003e\n\u003cli\u003eYou want integrated solar charge control and 2 MPPT trackers.\u003c\/li\u003e\n\u003cli\u003eYour battery system uses a nominal 48V DC architecture.\u003c\/li\u003e\n\u003cli\u003eYou need to coordinate solar, battery, utility, and generator power.\u003c\/li\u003e\n\u003cli\u003eRemote monitoring through Wi-Fi and LAN hardware is important to your system planning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore purchasing, confirm that the inverter's voltage, current, PV input, battery requirements, output configuration, and other system specifications match your planned installation. Customers should also confirm application-specific installation and compatibility details before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSol-Ark 5K-2P Common Questions\u003c\/h3\u003e\n\u003ch4\u003eHow Much Power Does The Sol-Ark 5K-2P Provide\u003c\/h4\u003e\n\u003cp\u003eThe inverter provides \u003cstrong\u003e5,000W of maximum continuous real power\u003c\/strong\u003e. Its maximum output current is 20.8A.\u003c\/p\u003e\n\u003ch4\u003eWhat Battery Voltage Does The Sol-Ark 5K-2P Use\u003c\/h4\u003e\n\u003cp\u003eThe nominal battery voltage is 48V, with an operating voltage range of 43–63V. It supports lithium and lead-acid battery technologies.\u003c\/p\u003e\n\u003ch4\u003eHow Much Solar Input Can The Sol-Ark 5K-2P Handle\u003c\/h4\u003e\n\u003cp\u003eThe maximum allowed PV power at STC is 6,500W. It has 2 MPP trackers, with 2 PV strings per MPPT, and a maximum input voltage of 500V.\u003c\/p\u003e\n\u003ch4\u003eCan The Sol-Ark 5K-2P Work With A Generator\u003c\/h4\u003e\n\u003cp\u003eYes. The provided specifications include an integrated 2-wire Automatic Generator Start function, and the inverter is designed to manage generator power alongside solar, battery, and utility power.\u003c\/p\u003e\n\u003ch4\u003eDoes The Sol-Ark 5K-2P Include Remote Monitoring Hardware\u003c\/h4\u003e\n\u003cp\u003eYes. Wi-Fi and LAN hardware is included for communication and monitoring.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 56.375px;\"\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%; height: 56.375px;\"\u003e\n\u003ch3\u003eSol-Ark 5K-2P Hybrid Inverter System Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eSol-Ark-5K-48-ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e5K-2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Allowed PV Power (STC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e6,500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eRated MPPT Operating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e175–425V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMPPT Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e150–500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStartup Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMax. Operating Input Current per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e10A (Self-Limiting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo. of MPP Trackers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo. of PV Strings per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. AC Coupled Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e9,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal AC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e120\/240V, 120\/208V, 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGrid Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50 \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eReal Power, Max Continuous\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e5,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e20.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePeak Apparent Power (10s, Off-Grid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e16,000VA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePeak Apparent Power (100ms, Off-Grid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e25,000VA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Output Fault Current (100ms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e104A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Grid Passthrough Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Factor Output Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e+\/- 0.9 Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBackup Transfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e4ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCEC Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e96.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eDesign (DC to AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eTransformerless DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStackable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Technologies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eLithium \/ Lead Acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Operating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e43–63V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50–9,900Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMax. Battery Charge \/ Discharge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCharging Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e3-Stage with Equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGrid to Battery Charging Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eExternal Battery Temperature Sensor (BTS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAutomatic Generator Start (AGS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2-Wire Start – Integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBMS Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eCANBus \u0026amp; RS485 MODBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e750 x 450 x 254 mm (29.5 x 17.7 x 10 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e35.4 kg \/ 78 lb.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIP65 \/ NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e-25–55°C, \u0026gt; 45°C Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e\u0026lt; 30 dB @ 25°C (77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eIdle Consumption – No Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication and Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eWi-Fi \u0026amp; LAN Hardware Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandard Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e10 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePV DC Disconnect Switch — NEC 240.15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eGround Fault Detection — NEC 690.5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePV Rapid Shutdown Control — NEC 690.12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Arc Fault Detection — NEC 690.11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Input Lightning Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003ePV String Input Reverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAC Output Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e63A, Integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Breaker \/ Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e250A, Integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eDC Type II \/ AC Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 58.7812px;\"\u003e\u003cstrong\u003eGrid-Interactive Certifications And Listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 58.7812px;\"\u003eUL1741-2010\/2018, IEEE1547a-2003\/2014, FCC 15 Class B, UL1741SB, CA Rule 21, HECO Rule 14H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eWhat’s Included \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Sol-Ark 5K-2P Hybrid Inverter System\u003c\/li\u003e\n\u003cli\u003e1 x External Battery Temperature Sensor\u003c\/li\u003e\n\u003cli\u003e1 x Wi-Fi And LAN Hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eBuild Your Power System With Outbound Power\u003c\/h3\u003e\n\u003cp\u003eThe Sol-Ark 5K-2P is built around practical energy management rather than a single power source. With 5,000W continuous output, 6,500W maximum allowed PV input, 48V battery support, 2 MPPT trackers, generator management, remote monitoring, and integrated protection features, it provides clearly defined specifications for designing a hybrid backup or off-grid power system.\u003c\/p\u003e\n\u003cp\u003eFor customers planning a more capable energy setup, choosing the inverter is only one part of the process. Battery voltage and capacity, solar input, output requirements, and available power sources all need to work together. \u003cstrong\u003eOutbound Power\u003c\/strong\u003e can help you evaluate the product specifications and build a power solution around your actual requirements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSol-Ark 5K-2P Hybrid Inverter System Manuals\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_5K-2P_Hybrid_Inverter_System_Manuals.pdf?v=1790600694\" title=\"Sol-Ark 5K-2P Hybrid Inverter System Manuals\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_5K-2P_Hybrid_Inverter_System_Manuals_100x100.jpg?v=1790600675\" alt=\"Sol-Ark_5K-2P_Hybrid_Inverter_System_Manuals\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Sol-Ark","offers":[{"title":"Default Title","offer_id":49118984175865,"sku":"SA-5K-2P","price":4699.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_5K-2P_Hybrid_Inverter_System_-_product_image_1.png?v=1790607431","url":"https:\/\/outboundpower.com\/products\/sol-ark-5k-2p","provider":"Outbound Power","version":"1.0","type":"link"}