{"product_id":"sol-ark-60k-3p","title":"Sol-Ark 60K-3P-480V Hybrid Inverter System","description":"\u003ch2\u003eSol-Ark 60K-3P-480V Hybrid Inverter System Delivers 60,000W For Commercial And Industrial Power Management\u003c\/h2\u003e\n\u003cp\u003eThe Sol-Ark 60K-3P-480V Hybrid Inverter System is designed for commercial and industrial solar-plus-storage applications that require substantial three-phase power management. With 60,000W of continuous three-phase output at 277\/480V, four MPPT trackers, 200A grid pass-through, and integrated management of solar, battery, grid, and generator power, it provides a central platform for coordinating multiple energy sources. It supports grid-connected, off-grid, and battery backup operating modes while offering remote monitoring through included Wi-Fi and LAN hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSol-Ark 60K-3P-480V Hybrid Inverter System Features\u003c\/h3\u003e\n\u003ch4\u003e60,000W Three-Phase Output For High-Demand Power Systems\u003c\/h4\u003e\n\u003cp\u003eThe inverter provides up to 60,000W of continuous real power through a 277\/480V three-phase AC output. Its maximum output current is 72.3A, while its seven-second off-grid peak apparent power reaches 120,000VA at 144A. That combination gives system designers substantial output capacity for larger commercial and industrial electrical loads.\u003c\/p\u003e\n\u003ch4\u003eFour MPPT Trackers So You Can Manage Large Solar Arrays\u003c\/h4\u003e\n\u003cp\u003eFour independent maximum power point trackers help manage solar input across a larger PV system. The inverter accepts up to 78,000W of PV power at STC, with a nominal PV voltage range of 150–850V and maximum input voltage of 1,000V. Each MPPT supports up to 36A of input current and two PV strings.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e78,000W maximum allowed PV power at STC\u003c\/li\u003e\n\u003cli\u003eFour MPP trackers\u003c\/li\u003e\n\u003cli\u003eTwo PV strings per MPPT\u003c\/li\u003e\n\u003cli\u003e150–850V nominal PV voltage range\u003c\/li\u003e\n\u003cli\u003e1,000V maximum input voltage\u003c\/li\u003e\n\u003cli\u003e120,000W maximum AC-coupled input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHybrid Energy Management For Flexible Power Planning\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 60K-3P-480V combines hybrid inverter and solar charge control functions while managing solar, battery, grid, and generator power. Grid-connected, off-grid, and battery backup operating modes allow the system to be configured around different power-management requirements rather than relying on a single operating method.\u003c\/p\u003e\n\u003ch4\u003e200A Grid Pass-Through For Larger Electrical Systems\u003c\/h4\u003e\n\u003cp\u003eWith a maximum grid pass-through current of 200A, this system is built to handle substantial grid-connected power flows. A 5ms adjustable backup transfer time also supports rapid transitions for backup operation. The output power factor is adjustable from +\/- 0.8, providing additional flexibility when designing the electrical system.\u003c\/p\u003e\n\u003ch4\u003eHigh-Voltage Battery Support For Scalable Storage\u003c\/h4\u003e\n\u003cp\u003eThe battery input is designed around lithium iron phosphate batteries with two battery inputs and a nominal DC voltage above 600V. The operating voltage range is 160–800V, with a battery capacity range of 50–9,900Ah and a maximum battery charge or discharge current of 100A, or 50A per input.\u003c\/p\u003e\n\u003cp\u003eActive BMS communication is required for lithium batteries. The inverter supports CANBus and RS485 BMS communication, helping coordinate battery operation with the larger energy system.\u003c\/p\u003e\n\u003ch4\u003eParallel Operation For Expanded System Capacity\u003c\/h4\u003e\n\u003cp\u003eThe Sol-Ark 60K-3P-480V can be stacked with up to 12 units in parallel. This provides an expansion path for system designs that require multiple inverters rather than relying on a single inverter for the entire installation.\u003c\/p\u003e\n\u003ch4\u003eIntegrated Protection For Solar And Power System Equipment\u003c\/h4\u003e\n\u003cp\u003eProtection features are integrated into the inverter, including a PV DC disconnect, ground fault detection, PV rapid shutdown control, PV arc fault detection, PV input lightning protection, and PV string reverse polarity protection. Surge protection is provided through DC Type II and AC Type III protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eReal-World Applications For Commercial And Industrial Power\u003c\/h3\u003e\n\u003cp\u003eThe Sol-Ark 60K-3P-480V is intended for substantial stationary energy systems rather than portable power applications. Its three-phase 277\/480V output, high PV input capacity, high-voltage battery architecture, and grid pass-through capability make it relevant to commercial and industrial solar storage projects.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial backup power\u003c\/strong\u003e where substantial three-phase loads need battery-supported energy management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial solar storage\u003c\/strong\u003e where large PV arrays and high-voltage battery storage are part of the system design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrid-connected solar systems\u003c\/strong\u003e requiring integrated management of solar, grid, and battery power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid power systems\u003c\/strong\u003e designed around high-capacity three-phase loads and battery storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator-supported systems\u003c\/strong\u003e using the integrated automatic generator start function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eSol-Ark 60K-3P-480V Compared With Smaller Inverter Systems\u003c\/h3\u003e\n\u003cp\u003eSmaller residential inverters and portable power stations are designed around lower power requirements and different electrical configurations. The Sol-Ark 60K-3P-480V operates at a 277\/480V three-phase output and provides 60,000W of continuous real power, making it a substantially different class of equipment.\u003c\/p\u003e\n\u003cp\u003eIt is also more than a standalone solar inverter. Its integrated hybrid functionality combines solar charge control with management of battery, grid, and generator power. The ability to operate in grid-connected, off-grid, and battery backup modes gives system designers more options for configuring a larger energy system.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eBuyer Guidance For The Sol-Ark 60K-3P-480V Hybrid Inverter System\u003c\/h3\u003e\n\u003cp\u003eThis inverter is best considered as part of a professionally planned commercial or industrial power system. Before purchasing, customers should verify that the system's electrical requirements, PV array, battery configuration, and operating environment align with the inverter's specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis May Be A Good Fit If:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou need up to 60,000W of continuous three-phase AC output.\u003c\/li\u003e\n\u003cli\u003eYour project uses a 277\/480V three-phase electrical configuration.\u003c\/li\u003e\n\u003cli\u003eYou are planning a solar array up to the stated 78,000W PV input rating.\u003c\/li\u003e\n\u003cli\u003eYou need high-voltage lithium iron phosphate battery integration.\u003c\/li\u003e\n\u003cli\u003eYou want grid-connected, off-grid, and battery backup operating modes.\u003c\/li\u003e\n\u003cli\u003eYou need substantial grid pass-through capacity up to 200A.\u003c\/li\u003e\n\u003cli\u003eYou may need to parallel multiple inverter units, with up to 12 units supported.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCustomers should also confirm battery BMS communication requirements before purchase, since active BMS communication is required for lithium batteries. The datasheet information provided also identifies CEC and SGIP listings as pending, so customers who require those specific listings should confirm their current status before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eCommon Questions About The Sol-Ark 60K-3P-480V\u003c\/h3\u003e\n\u003ch4\u003eHow Much Power Does The Sol-Ark 60K-3P-480V Provide?\u003c\/h4\u003e\n\u003cp\u003eThe inverter provides 60,000W of maximum continuous real power through its three-phase AC output. Its nominal AC voltage is 277\/480V.\u003c\/p\u003e\n\u003ch4\u003eHow Much Solar Input Can This Inverter Handle?\u003c\/h4\u003e\n\u003cp\u003eThe maximum allowed PV power is 78,000W at STC. The inverter has four MPPT trackers, with two PV strings per MPPT, and supports up to 1,000V maximum PV input voltage.\u003c\/p\u003e\n\u003ch4\u003eWhat Batteries Does The Sol-Ark 60K-3P-480V Use?\u003c\/h4\u003e\n\u003cp\u003eThe listed battery chemistry is lithium iron phosphate. The system has two battery inputs, supports 160–800V operating voltage, and requires active BMS communication for lithium batteries through CANBus and RS485.\u003c\/p\u003e\n\u003ch4\u003eCan Multiple Sol-Ark 60K-3P-480V Units Be Used Together?\u003c\/h4\u003e\n\u003cp\u003eYes. The listed specification states that the inverter is stackable with up to 12 units in parallel. The appropriate system configuration should be confirmed for the specific project.\u003c\/p\u003e\n\u003ch4\u003eDoes The Inverter Support Generator Integration?\u003c\/h4\u003e\n\u003cp\u003eYes. An integrated two-wire automatic generator start function is listed, allowing generator power to be managed as part of the broader energy system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 56.375px;\"\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%; height: 56.375px;\"\u003e\n\u003ch3\u003eSol-Ark 60K-3P-480V Hybrid Inverter System Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Allowed PV Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e78,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal PV Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e150–850V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStartup Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e150V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. PV Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e1,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Input Current Per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e36A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMax. Short Circuit Current Per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e55A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo. Of MPP Trackers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Strings Per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. AC Coupled Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e120,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal AC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e277\/480V, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGrid Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50 \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Continuous Real Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e60,000W, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e72.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePeak Apparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e120,000VA @ 144A for 7 Seconds, Off-Grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Grid Passthrough Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Factor Output Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e+\/- 0.8 Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBackup Transfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e5ms, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCEC Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e96.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eMax. Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eDC To AC Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eTransformerless DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eStackable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eUp To 12 In Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Chemistry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eLithium Iron Phosphate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo. Of Battery Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Input Terminal Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Battery DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e\u0026gt; 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Operating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e160–800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Capacity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e50–9,900Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 39.1875px;\"\u003e\u003cstrong\u003eMax. Battery Charge \/ Discharge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 39.1875px;\"\u003e100A, 50A Per Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCharge Controller Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e3-Stage With Equalization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGrid To Battery Charging Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e96.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAutomatic Generator Start\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e2-Wire Start, Integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eBMS Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eCANBus \u0026amp; RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e894 × 528 × 295 mm (35.2 × 20.8 × 11.6 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e172 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIP65 \/ NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e-40–60°C, \u0026gt; 45°C Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e\u0026lt; 30 dB @ 25°C (77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eIdle Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication And Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eWi-Fi \u0026amp; LAN Hardware Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003e10 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV DC Disconnect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eGround Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Rapid Shutdown Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Arc Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV Input Lightning Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003ePV String Reverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 19.5938px;\"\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 19.5938px;\"\u003eDC Type II \/ AC Type III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 44.1489%; height: 58.7812px;\"\u003e\u003cstrong\u003eCertifications And Listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%; height: 58.7812px;\"\u003eUL 1741-2021 Including UL 1741SB; CSA C22.2 No. 107.1-16; IEEE 1547-2018, 1547a-2020 \u0026amp; 1547.1-2020; UL 1699B; CEC And SGIP Pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eWhat’s Included \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Sol-Ark 60K-3P-480V Hybrid Inverter System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional included items or accessories were not specified in the provided product information. Confirm the exact shipment contents with Outbound Power before purchase if specific accessories or documentation are required.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eChoose The Sol-Ark 60K-3P-480V For Long-Term Power Planning\u003c\/h3\u003e\n\u003cp\u003eFor commercial and industrial projects, choosing an inverter is about more than a single output number. PV capacity, battery voltage, grid requirements, operating modes, communication, expansion, and protection all need to work together as part of the larger power system. The Sol-Ark 60K-3P-480V brings these functions together in a high-capacity three-phase hybrid inverter with 60,000W continuous output, four MPPT trackers, high-voltage battery support, 200A grid pass-through, remote monitoring hardware, and support for parallel operation. Outbound Power can help you evaluate the specifications and system requirements so you can select power equipment that fits the project rather than simply buying more capacity than you need.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSol-Ark 60K-3P-480V Hybrid Inverter System Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"Sol-Ark%2060K-3P-480V%20Hybrid%20Inverter%20System%20Manual\" title=\"Sol-Ark 60K-3P-480V Hybrid Inverter System Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Manual_3399c5bb-bb09-4bf4-94f9-195fe3315da7_100x100.jpg?v=1790594146\" alt=\"Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Manual_8db5e9b0-96ec-4d09-93d8-84167a43601c\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ch3\u003eSol-Ark 60K-3P-480V Hybrid Inverter System Spec Sheet\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Spec_Sheet.pdf?v=1790594281\" title=\"Sol-Ark 60K-3P-480V Hybrid Inverter System Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Spec_Sheet_100x100.jpg?v=1790594264\" alt=\"Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Spec_Sheet\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSol-Ark 60K-3P-480V Hybrid Inverter System Brochure\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Brochure.pdf?v=1790594811\" title=\"Sol-Ark 60K-3P-480V Hybrid Inverter System Brochure\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Brochure_100x100.jpg?v=1790594342\" alt=\"Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_Brochure\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sol-Ark","offers":[{"title":"Default Title","offer_id":49118984700153,"sku":"SA-60K-3P","price":14625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/Sol-Ark_60K-3P-480V_Hybrid_Inverter_System_-_product_image_1.png?v=1790606187","url":"https:\/\/outboundpower.com\/products\/sol-ark-60k-3p","provider":"Outbound Power","version":"1.0","type":"link"}