{"product_id":"sungold-power-11-4kw-48v-split-phase-hybrid-solar-inverter-whole-home-backup-200a","title":"SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter | Whole Home Backup (200A)","description":"\u003cdiv style=\"float: left; padding: 10px 35px 20px 35px;\"\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\u003ciframe loading=\"lazy\" width=\"640\" height=\"300\" src=\"https:\/\/www.youtube.com\/embed\/zea3VoRR4s4\" title=\"SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter\" style=\"max-width: 100%; max-height: 100%;\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/noscript\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003ch2\u003eThe SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter Backs Up a Whole Home With 200A Grid Pass-Through and 15kW of Solar Input\u003c\/h2\u003e\n\u003cp\u003eThe SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter (model SGN-11K15PRO) is a hybrid inverter built for whole-home backup. It delivers 11.4kW of continuous 120\/240V output, accepts up to 15kW of solar on three MPPT inputs, and passes up to 200A of grid current through to your main panel. It works in off-grid, grid-tied and hybrid solar systems.\u003c\/p\u003e\n\u003cp\u003eIt runs on a 48V lithium-ion or lead-acid battery and charges or discharges at up to 10kW. An IP65 enclosure allows indoor or outdoor mounting, and an LCD touchscreen, Bluetooth and an app handle setup. It is aimed at homeowners who want the whole house, not just a critical loads panel, on backup.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eSunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter Features\u003c\/h3\u003e\n\u003ch4\u003e11.4kW Continuous With a 150% Peak\u003c\/h4\u003e\n\u003cp\u003eNominal output is 11.4kW and 47.5A at 120\/240V split phase or 120\/208V 2\/3 phase. The peak output apparent power is 150% for 10 seconds, transfer time is under 10ms, and voltage distortion stays below 3% at full resistive load.\u003c\/p\u003e\n\u003ch4\u003e200A Whole Home Backup\u003c\/h4\u003e\n\u003cp\u003eThe grid connects to the inverter's GRID terminal, and its LOAD output feeds your main panel, with a 200A maximum grid pass-through current. When the grid is up, the inverter passes utility power to the house. When it fails, the battery and solar take over.\u003c\/p\u003e\n\u003ch4\u003eThree MPPTs With 15kW of PV Input\u003c\/h4\u003e\n\u003cp\u003eThree MPPT trackers accept up to 15,000W of PV at up to 600V, with a 90V start-up voltage and a 70-540V operating range. Input currents are 30A, 22A and 22A. SunGold rates CEC efficiency at 96.50%.\u003c\/p\u003e\n\u003ch4\u003e10kW Battery Charging and Discharging\u003c\/h4\u003e\n\u003cp\u003eThe 48V battery port works from 40 to 64V with up to 210A and 10,000W of charge or discharge power. Lithium-ion batteries connect through the CAN BMS port, and lead-acid batteries are also supported.\u003c\/p\u003e\n\u003ch4\u003eWorking Modes and Time-Based Control\u003c\/h4\u003e\n\u003cp\u003eSunGold lists five working modes, including self-consumption, feed-in priority and back-up mode. A forced charge and discharge function can be set for three time periods a day and overrides the working mode during those periods.\u003c\/p\u003e\n\u003ch4\u003eGenerator, Smart Load and AC Coupling\u003c\/h4\u003e\n\u003cp\u003eThe GEN port accepts split phase (120\/240V) or 2\/3 phase (120\/208V) generators and can also be used for a smart load. AC coupling lets you connect an existing grid-tie inverter.\u003c\/p\u003e\n\u003ch4\u003eTouchscreen, Bluetooth and Parallel Capability\u003c\/h4\u003e\n\u003cp\u003eAn LCD touchscreen and LED indicators show system status, and Bluetooth and an app support setup and monitoring. Up to nine units can be paralleled, but touchscreen and non-touchscreen models cannot be paralleled together.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhole-home backup.\u003c\/strong\u003e Feed the main panel through the LOAD output so the house stays powered during outages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrid-tied homes adding storage.\u003c\/strong\u003e Use solar first, store the surplus and reduce power drawn from the utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTime-of-use rate plans.\u003c\/strong\u003e Schedule forced charging and discharging in up to three time periods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRural homes with a generator.\u003c\/strong\u003e Connect a split phase generator to the GEN port as a backup source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarger properties.\u003c\/strong\u003e Parallel additional units for more output.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eHow It Compares to Common Alternatives\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVersus the 7.6KW SGN7.6K1HB-48.\u003c\/strong\u003e Both share a 48V battery, three 600V MPPT inputs and split phase or 2\/3 phase output. This model raises output to 11.4kW and 47.5A, against 7.6kW and 31.7A, and battery discharge to 210A, against 180A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersus SunGold's high voltage 11.4KW hybrid.\u003c\/strong\u003e SunGold's other 11.4KW hybrid works with high-voltage lithium batteries. This model runs on a 48V battery and adds 200A grid pass-through for whole-home backup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersus a grid-tie inverter alone.\u003c\/strong\u003e A grid-tie inverter without a battery cannot power the home during an outage. This hybrid adds battery storage, backup and generator input.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eIs This Hybrid Inverter the Right Fit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery.\u003c\/strong\u003e Requires a 48V lithium-ion or lead-acid battery within 40-64V, with 4\/0 AWG battery cable or two 2 AWG cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar array.\u003c\/strong\u003e Up to three strings within 70-540V and no more than 600V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService wiring.\u003c\/strong\u003e GRID and LOAD conductors are 2\/0 to 4\/0 AWG, and an external breaker is required between the grid and the inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge loads.\u003c\/strong\u003e SunGold's manual advises against putting loads with very high start-up surges, such as air conditioners and high-power pumps, on the load port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize and weight.\u003c\/strong\u003e 17.6 x 35.5 x 10.6 inches and 103.6 lbs. Two or three people are recommended for mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis may be a good fit if\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou want whole-home backup on a 48V battery\u003c\/li\u003e\n\u003cli\u003eYour home has a 200A main panel\u003c\/li\u003e\n\u003cli\u003eYour array splits into up to three strings\u003c\/li\u003e\n\u003cli\u003eYou need grid support certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eHow Does Whole Home Backup Work?\u003c\/h4\u003e\n\u003cp\u003eThe utility connects to the GRID terminal, and the LOAD output connects to your main panel. The inverter passes up to 200A from the grid and switches the house to battery and solar power, typically in under 10ms, when the grid fails.\u003c\/p\u003e\n\u003ch4\u003eCan I Parallel It With Other SunGold Hybrids?\u003c\/h4\u003e\n\u003cp\u003eUp to nine units can run in parallel. Touchscreen and non-touchscreen models cannot be paralleled, so match models before ordering.\u003c\/p\u003e\n\u003ch4\u003eCan It Be Installed Outdoors?\u003c\/h4\u003e\n\u003cp\u003eYes. It is rated IP65 and NEMA 3R and operates from -13°F to 140°F, with derating above 113°F. SunGold recommends a sheltered spot out of direct sun, rain and snow.\u003c\/p\u003e\n\u003ch4\u003eWhich Certifications Does It Carry?\u003c\/h4\u003e\n\u003cp\u003eUL 1741, CSA C22.2, UL 1699B, UL 1741SA, UL 1741SB, UL 1741 PCS CRD, IEEE 1547, HECO SRD 2.0 and CSIP.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter (SGN-11K15PRO)\u003c\/li\u003e\n\u003cli\u003e1 x Mounting Bracket\u003c\/li\u003e\n\u003cli\u003e1 x File Package\u003c\/li\u003e\n\u003cli\u003e1 x CT Pack\u003c\/li\u003e\n\u003cli\u003e4 x M6 Expansion Screws\u003c\/li\u003e\n\u003cli\u003e1 x M6 Security Screw\u003c\/li\u003e\n\u003cli\u003e1 x 9-Pin Terminal\u003c\/li\u003e\n\u003cli\u003e4 x 4-Pin Terminals\u003c\/li\u003e\n\u003cli\u003e2 x Toroids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhole-Home Backup on a 48V Battery\u003c\/h3\u003e\n\u003cp\u003eThe SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter combines 11.4kW of output, 15kW of solar input and 200A grid pass-through in one IP65 unit with a 10-year warranty. At Outbound Power, we help customers plan whole-home backup, battery banks and solar arrays. If you have questions, our team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eSunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003eSGN-11K15PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCEC Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInput (PV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. PV Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. PV Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStart-Up Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPPT Operating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70V to 540V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Input Current per MPPT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A \/ 22A \/ 22A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of MPPTs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eInput \/ Output (Battery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Battery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLithium-ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40V to 64V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Charge \/ Discharge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210A \/ 210A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Charge \/ Discharge Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000W \/ 10,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput (Grid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal AC Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. AC Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Grid Pass-Through Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Grid Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V (split phase), 120\/208V (2\/3 phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Grid Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.99 at rated power (adjustable 0.8 lagging to 0.8 leading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOutput (Load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Output Apparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150%, 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V (split phase), 120\/208V (2\/3 phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTHDV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3% at 100% resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Overcurrent Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC\/AC Overvoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Type II, AC Type III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Short Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Reverse Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Arrester\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Type II, AC Type III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRapid Shutdown (RSD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13°F to 140°F (derating above 113°F), -25°C to 60°C (derating above 45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.6 x 35.5 x 10.6 in (448 x 901 x 270 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.6 lbs (47 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eHMI and Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED + LCD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN (BMS), RS485 (meter), RS485, CAN (parallel); optional Wi-Fi \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBluetooth and app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1741, CSA C22.2, UL 1699B, UL 1741SA, UL 1741SB, UL 1741 PCS CRD, IEEE 1547, HECO SRD 2.0, CSIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eSunGold Power 11.4KW 48V Manual\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca rel=\"noopener\" title=\"SunGold Power 11.4KW 48V Split Phase Hybrid Solar Inverter Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/SunGold_Power_11.4KW_48V_Split_Phase_Hybrid_Solar_Inverter_Manual.pdf?v=1774278109\" target=\"_blank\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"SunGold_Power_11.4KW_48V_Split_Phase_Hybrid_Solar_Inverter_Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/SunGold_Power_11.4KW_48V_Split_Phase_Hybrid_Solar_Inverter_Manual_100x100.jpg?v=1774278104\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"SunGold Power","offers":[{"title":"Default Title","offer_id":47553997078777,"sku":"SGN-11K15PRO","price":3100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/SunGold_Power_11.4KW_48V_Split_Phase_Hybrid_Solar_Inverter.jpg?v=1774279420","url":"https:\/\/outboundpower.com\/products\/sungold-power-11-4kw-48v-split-phase-hybrid-solar-inverter-whole-home-backup-200a","provider":"Outbound Power","version":"1.0","type":"link"}