{"product_id":"sungold-power-300-amp-dc-breaker","title":"SunGold Power 300 Amp DC Breaker","description":"\u003ch2\u003eThe SunGold Power 300 Amp DC Breaker Protects High-Current Battery Circuits and Gives You a Manual Disconnect\u003c\/h2\u003e\n\u003cp\u003eThe SunGold Power 300 Amp DC Breaker is a two-pole molded case circuit breaker from SunGold's SG-C series. It protects DC circuits against overloads and short circuits, and it doubles as a manual disconnect between a battery bank and an inverter.\u003c\/p\u003e\n\u003cp\u003eSunGold built it for larger battery banks and higher-power inverter systems. It suits installers wiring solar energy storage, off-grid or backup power systems who need a 300A protection point on the battery side.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eSunGold Power 300 Amp DC Breaker Features\u003c\/h3\u003e\n\u003ch4\u003e300A Rating up to 500V DC\u003c\/h4\u003e\n\u003cp\u003eThe breaker is rated at 300A, with a rated operating voltage of DC12V to 500V.\u003c\/p\u003e\n\u003ch4\u003e25kA Short-Circuit Breaking Capacity\u003c\/h4\u003e\n\u003cp\u003eSunGold rates the short-circuit breaking capacity (Icu) at 25kA and the rated breaking capacity (Ics) at 20kA. A thermo-magnetic release handles both sustained overloads and short circuits.\u003c\/p\u003e\n\u003ch4\u003eBidirectional for Charging and Discharging\u003c\/h4\u003e\n\u003cp\u003eThe breaker supports battery charging and discharging, with the same overcurrent protection in either direction. Only the short-circuit breaking capacity changes with the wiring direction.\u003c\/p\u003e\n\u003ch4\u003eManual Disconnect With Push to Trip\u003c\/h4\u003e\n\u003cp\u003eMarked ON and OFF positions let you isolate the battery or inverter for maintenance. A red button trips it by hand.\u003c\/p\u003e\n\u003ch4\u003ePanel Screw Mounting and Hexagon Screw Terminals\u003c\/h4\u003e\n\u003cp\u003eIt mounts with panel screws and connects through hexagon screw terminals tightened to 5.0N.m. SunGold recommends 350 kcmil cable for the 300A rating.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eReal-World Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMain battery disconnect.\u003c\/strong\u003e Place it between a large battery bank and an inverter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar energy storage.\u003c\/strong\u003e Protect the energy storage side of a photovoltaic system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOff-grid and backup power.\u003c\/strong\u003e Isolate the DC side of an off-grid or backup system for service.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003ePractical Comparison\u003c\/h3\u003e\n\u003ch4\u003eSunGold Power 300 Amp DC Breaker Versus a Fuse\u003c\/h4\u003e\n\u003cp\u003eA fuse protects against overcurrent but has to be replaced once it blows. This breaker can be switched back on after a trip and also works as a disconnect.\u003c\/p\u003e\n\u003ch4\u003eSunGold Power 300 Amp DC Breaker Versus the 160A SG-C Model\u003c\/h4\u003e\n\u003cp\u003eBoth share the same voltage rating, breaking capacity and frame size. The 300A model suits bigger battery banks, and SunGold pairs it with 350 kcmil cable instead of the 2\/0 AWG cable it lists for 160A.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eBuyer Guidance\u003c\/h3\u003e\n\u003ch4\u003eMounting and Operating Conditions\u003c\/h4\u003e\n\u003cp\u003eMount it vertically with the arc chamber on top. SunGold prohibits horizontal and upside-down mounting and asks for arc flash clearance above it. It is rated for -10°C to +40°C ambient air, and its current correction coefficient falls to 0.85 at 40°C.\u003c\/p\u003e\n\u003ch4\u003eThis May Be A Good Fit If\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYour battery circuit needs a 300A DC breaker\u003c\/li\u003e\n\u003cli\u003eYour system runs at 500V DC or less\u003c\/li\u003e\n\u003cli\u003eYou want overload protection and a disconnect in one part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003ch4\u003eWhich Terminals Connect to the Battery?\u003c\/h4\u003e\n\u003cp\u003eConnect the battery to the top LINE terminals and the inverter or load to the bottom LOAD terminals. This normal connection gives the full 25kA breaking capacity when the battery discharges.\u003c\/p\u003e\n\u003ch4\u003eHow Do I Reset It After a Trip?\u003c\/h4\u003e\n\u003cp\u003ePush the handle down to OFF first, then push it up to switch it on. The handle can't be pushed up while the breaker is tripped.\u003c\/p\u003e\n\u003ch4\u003eShould a Professional Install It?\u003c\/h4\u003e\n\u003cp\u003eYes. SunGold says installation must be carried out by specialists.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x SunGold Power 300 Amp DC Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003eDependable Protection for Large Battery Banks\u003c\/h3\u003e\n\u003cp\u003eThe SunGold Power 300 Amp DC Breaker gives a high-current battery circuit overload protection, short-circuit protection and a manual disconnect in one part. At Outbound Power, we help customers size breakers, cables and batteries for their inverter setups. If you have questions, our team is happy to help.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ctable style=\"border-collapse: collapse; max-width: 100%; overflow-x: auto;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: rgb(242, 242, 242); text-align: left; width: 100%;\"\u003e\n\u003ch3\u003eSunGold Power 300 Amp DC Breaker Specifications\u003c\/h3\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.1489%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.8511%;\"\u003eSunGold Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSG-C300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSG-C DC Molded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC12V~500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp, 1.2\/50)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Short-Circuit Breaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu by Direction (Normal Connection)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA discharging, 15kA charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermo-magnetic, Curve (4-6In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBidirectional (charging and discharging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eMechanical and Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel screw installation, vertical only (arc chamber on top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHexagon screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Cable Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 kcmil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArcing Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 x 74 x 108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +40°C (24-hour average below +35°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: rgb(242, 242, 242);\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eSunGold Power SG-C300A Data Sheet\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/sungold-power-sg-c-dc-breaker-data-sheet.pdf?v=1793396981\" title=\"SunGold Power SG-C300A Data Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/sungold-power-sg-c300a-data-sheet.jpg?v=1793397119\" alt=\"SunGold Power SG-C300A Data Sheet\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"SunGold Power","offers":[{"title":"Default Title","offer_id":67514152943865,"sku":"SG-C300A","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0643\/9128\/2937\/files\/sungold-power-300-amp-dc-breaker-sg-c300a-angled-view-with-green-off-handle.jpg?v=1793154310","url":"https:\/\/outboundpower.com\/products\/sungold-power-300-amp-dc-breaker","provider":"Outbound Power","version":"1.0","type":"link"}