The Epoch Batteries 12V 460Ah (5.89kWh) LiFePO4 Battery Gives a 12V System Victron CAN, Self-Heating and Bluetooth in One IP67 Case
The Epoch C12460A is a V2 Elite Series lithium iron phosphate battery rated at 12.8V nominal and 460Ah, for 5,888Wh (5.89kWh) of stored energy in one managed case with one BMS. Instead of building a large house bank from several smaller batteries, you wire one battery, with fewer interconnects and cleaner routing.
It's made for large 12V house-power and energy-storage systems in RVs, camper vans, boats, off-grid cabins, solar banks and home backup, with Victron CAN communication, Bluetooth monitoring and self-heating built in. It is a deep-cycle battery, not for engine starting.
Epoch Batteries 12V 460Ah (5.89kWh) LiFePO4 Battery Features
Native Victron CAN Communication
The battery connects to a compatible Victron GX device (Cerbo GX, Ekrano GX or Cerbo GX Mk2) over CAN bus at 500 kbit/s, using the included harness. With DVCC on and Epoch set as the controlling BMS and battery monitor, it reports its status and sets the charge voltage and current limits of your Victron chargers.
Self-Heating for Charging in the Cold
LiFePO4 cells must not be charged below 0°C (32°F). When a charge source is connected and the cells are too cold, the BMS holds off charging while the internal heater, powered by the charge source, warms them. Charging resumes when the cells reach 5°C (41°F), and with self-heating, charging is supported from -30°C (-22°F) ambient.
IP67 Dust-Tight, Immersion-Rated Enclosure
The enclosure is dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes. It is not rated for water jets, pressure washing or continuous submersion, so install it where it stays dry in normal use, with all harness connectors fully seated.
230A Continuous Charge and Discharge
Epoch rates it for 230A continuous discharge and charge (0.5C, also Epoch's recommended rate), about 2,944W DC at 12.8V before inverter losses. For inverter surge it supplies 500A for 30 seconds and 1,300A for 1 second, and it accepts up to 400A of charge for 5 seconds.
Bluetooth Monitoring for Each Battery and the Bank
The included battery gauge shows state of charge and links over Bluetooth 4.0 to the Epoch Li-Ion app (iOS and Android). The app shows voltage, current, cell voltages, temperatures, history and warnings, offers series and parallel bank views, and installs firmware updates over the air.
Smart BMS and 400A Internal Fuse
The BMS protects against over- and under-voltage, over-current, short circuit and high or low temperature, backed by a 400A internal fuse (UL 60691). Epoch lists UL 1973 for the pack and UL 1642, UL 9540A and IEC 62619:2022 for the cells. The internal fuse protects the battery, not your cables, so you still need a DC-rated fuse or breaker close to the battery positive.
3,500+ Cycles and an 11-Year Limited Warranty
Epoch rates it for 3,500+ cycles to 70% remaining capacity at 25°C, with no watering or equalizing. It's backed by an 11-year limited warranty with free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11.
Real-World Applications
RV and van house power. Run a motorhome, travel trailer, fifth wheel or camper van from one battery, mounted upright and secured against vibration and braking.
Marine house banks. Power electronics, refrigeration, lighting, pumps and onboard AC loads through an inverter on yachts and cruising boats, with the battery installed where it stays dry in normal use.
Off-grid solar and cabins. Start with one 5.89kWh battery and grow to as many as 16 in parallel for 7,360Ah and 94.21kWh at 12.8V.
48V-class strings. Wire 4 in series for 51.2V nominal, with every component rated for the 58.4V the string reaches at full charge.
Home backup and large inverters. Epoch's planning estimates use 80% of nominal energy (about 4,710Wh) for a constant DC load, before inverter losses: about 9.4 hours at 500W, 4.7 hours at 1,000W and 1.6 hours at 2,944W.
How It Compares to Common Alternatives
Versus a bank of smaller 12V batteries. Building the same capacity from 100Ah-class batteries means four or more cases and more interconnect cables. This battery holds 5.89kWh behind one BMS.
Versus the V2-T version (C12460A-A). Epoch's 12V 460Ah V2-T Elite uses a user-serviceable Class T fuse and has its own manual. Check the model number on the label before you follow any procedure.
Versus a Group 8D lead-acid battery. If you're replacing an 8D, confirm tray fit, hold-down and lid clearance first. This battery needs no watering, and lead-acid equalization, desulfation or repair modes must not be used on it.
Is This 12V Battery the Right Fit
-
Bank limits. Up to 16 in parallel or up to 4 in series, using matched C12460A batteries of the same age, capacity and state of charge, with the DIP switches set for the bank. Series-parallel arrays are not covered by Epoch's published DIP switch settings.
-
Charger settings. Lithium (LiFePO4) CC/CV, 14.2V absorption for 15 minutes per battery in the bank, 13.5V float, 13.3V re-bulk, equalization and temperature compensation disabled, and 230A maximum per battery. Never charge above 14.6V. Program every charge source, Victron included, in case CAN communication is lost.
-
Cold charging. Below freezing, the heater must warm the cells before charge current flows, so expect a delay before the state of charge starts to rise.
-
Fit and weight. 20.86 x 8.65 x 12.06 in (529.8 x 219.8 x 306.3 mm) including terminal posts, and 97 lb (approx. 44 kg). Lift with two people or a lifting aid and install it upright. The Epoch V2 & V2-T Mounting Hardware (8D battery bracket) is sold separately.
-
Installation. Epoch calls for qualified installers. Torque the M8 terminals to 8–12 N·m, and charge fully before first use, since it ships at about 30%.
This may be a good fit if
- You're building or upgrading a large 12V house bank
- You use a Victron Cerbo GX, Ekrano GX or Cerbo GX Mk2
- You need to charge in freezing weather
- You'd rather wire one battery than several small ones
Common Questions
Do I Need a Special Cable for My Cerbo GX?
Not for a single battery. The included harness has a grey RJ45 plug for the BMS-CAN port on a Cerbo GX or Ekrano GX. On a Cerbo GX Mk2, use VE.Can 1 or VE.Can 2 and set the port speed to 500 kbit/s. For a bank, add RJ45 cables that link each battery's black port to the next battery's blue port.
How Cold Can It Discharge?
Discharge is rated from -20°C to 55°C (-4°F to 131°F), with no heating needed.
What Happens if CAN Communication Is Lost?
The BMS still protects the battery on its own, and Bluetooth monitoring works with or without a GX device. Your chargers fall back to their programmed settings, which is why each one should be set to Epoch's values.
How Should I Store It?
Charge it to at least 50%, switch it off and disconnect loads and chargers. Store it at 0 to 35°C (32 to 95°F) for up to a year, and check the state of charge at least every 3 months, since the warranty does not cover a battery left uncharged for more than 3 months.
What's Included
- 1 x Epoch 12V 460Ah V2 Elite LiFePO4 Battery (C12460A)
- 1 x Communication and Wiring Harness
- 1 x Battery Gauge (Bluetooth State-of-Charge Meter)
- 1 x External Power Button
- 1 x User Manual
One-Case 12V Storage for Victron and Off-Grid Systems
The Epoch Batteries 12V 460Ah (5.89kWh) LiFePO4 Battery gives a 12V system 5.89kWh in one IP67 case, with Victron CAN communication, self-heating and Bluetooth monitoring. If you have questions about charger settings, Victron setup or sizing a bank, the Outbound Power team is happy to help.
Epoch C12460A Specifications
|
| Electrical |
| Model |
C12460A |
| Series |
V2 Elite Series |
| Battery type |
Deep-cycle (not for engine starting) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell type |
Prismatic LiFePO4 |
| Cell configuration |
4S2P (230Ah cells) |
| Nominal voltage |
12.8V (3.2V per cell) |
| Nominal capacity |
460Ah (0.5C, 25°C) |
| Stored energy |
5,888Wh (5.89kWh) |
| Operating voltage range |
10.0–14.6V |
| Maximum charge voltage |
14.6V (3.65V per cell) |
| Minimum voltage |
10.0V (2.5V per cell) |
| Working SOC range |
0–100% |
| Self-discharge |
≤3% per month (100% SOC, 25°C) |
| State of charge at shipment |
30% ± 3% |
| Insulation resistance |
≥20 MΩ at 1,000V DC (25 ± 5°C, 50% RH) |
| Cycle life |
3,500+ cycles to 70% remaining capacity (25°C) |
| Charge and Discharge |
| Recommended continuous discharge |
230A (0.5C) |
| Maximum continuous discharge |
230A |
| Peak discharge |
500A for 30 s; 1,300A for 1 s |
| Continuous power at 12.8V |
2,944W DC (before inverter losses) |
| Recommended continuous charge |
230A (0.5C) |
| Maximum continuous charge |
230A |
| Maximum charge, short duration |
400A for 5 s |
| Series connection |
Up to 4 batteries (51.2V nominal) |
| Full-charge voltage, 4 in series |
58.4V |
| Parallel connection |
Up to 16 batteries |
| Maximum parallel bank |
7,360Ah / 94.21kWh at 12.8V nominal |
| Series-parallel |
Not covered by Epoch's published DIP switch settings |
| Recommended Charge Settings |
| Charger type |
Lithium (LiFePO4) compatible, CC/CV |
| Bulk / absorption voltage |
14.2V |
| Absorption time |
15 min per battery in the bank |
| Float voltage |
13.5V |
| Re-bulk voltage |
13.3V |
| Equalization |
Disabled |
| Temperature compensation |
Disabled (0 mV/°C) |
| Charge current |
230A (0.5C) per battery, recommended and max. continuous |
| BMS high-voltage cutoff |
14.6V |
| SOC recalibration |
14.6V (manual) |
| SOC recalibration with Victron |
Custom algorithm under Victron communication |
| Victron GX (DVCC) |
DVCC on; controlling BMS and battery monitor set to Epoch |
| Alternators |
DC-DC charger, or alternator regulator set up for lithium |
| Standard charge (rating method) |
CC ≤0.5C to 14.4V (3.60V per cell), CV to 0.02C, 25°C |
| Temperature |
| Charge (cell temperature) |
0 to 55°C (32 to 131°F) |
| Charge with self-heating (ambient) |
−30 to 55°C (−22 to 131°F) |
| Charging resumes after heating |
Cells at 5°C (41°F) |
| Self-heating power |
From the charge source |
| Discharge |
−20 to 55°C (−4 to 131°F) |
| Storage, up to 1 month |
−20 to 45°C (−4 to 113°F) |
| Storage, up to 1 year |
0 to 35°C (32 to 95°F) |
| Preferred operating temperature |
15 to 25°C (59 to 77°F) |
| Cooling |
Natural (passive) convection |
| BMS and Protection |
| Overcharge |
3.65 ± 0.01V per cell (14.6V) |
| Overcharge release |
3.45 ± 0.01V per cell (13.8V) |
| Over-discharge |
2.70 ± 0.05V per cell (10.8V) |
| Over-discharge release |
3.00 ± 0.05V per cell (12.0V) |
| Charge over-current |
400A, 5,000 ms delay; release 350A |
| Discharge over-current |
550A, 5,000 ms delay |
| Short circuit |
1,200A |
| Charge temperature protection |
Low 0°C (release 5°C); high 55°C (release 50°C) |
| Discharge temperature protection |
Low −20°C (release −17°C); high 55°C (release 50°C) |
| Internal fuse |
400A rated, UL 60691 (TEX150-R1N-XBZ) |
| Internal fuse transient overload |
1,200A for 3 s |
| Self-consumption |
20mA powered on; 200µA powered off |
| Communication and Monitoring |
| Bluetooth |
Bluetooth 4.0 through the included battery gauge |
| App |
Epoch Li-Ion (iOS and Android) |
| Bluetooth range |
Typically about 10 m (33 ft) |
| CAN bus |
500 kbit/s |
| Victron GX port |
BMS-CAN or VE.Can |
| Victron GX devices |
Cerbo GX, Ekrano GX, Cerbo GX Mk2 |
| Firmware updates |
Over the air through the app (EMS, then BMS) |
| Controls |
Power button; external power button included |
| DIP switches |
8 (battery role and bank position) |
| Size and Weight |
| Dimensions (L x W x H) |
20.86 in x 8.65 in x 12.06 in (529.8 x 219.8 x 306.3 mm) |
| Height note |
Includes terminal posts |
| Case height (body) |
11.54 in (293.0 mm) |
| Terminal spacing |
17.99 in (457.0 mm), center to center |
| Weight |
97 lb (approx. 44 kg) |
| Terminals |
M8 threaded |
| Terminal torque |
8–12 N·m (71–106 lbf·in) |
| Mounting orientation |
Upright |
| Mounting points |
Six M8 nuts, 125 mm (4.92 in) spacing |
| Mounting bracket |
Epoch V2 & V2-T Mounting Hardware (8D battery bracket), sold separately |
| Case material |
ABS + PC blend, UL94 V-0 |
| Enclosure |
IP67, dust-tight |
| Water protection |
Temporary immersion to 1 m for 30 min |
| Not rated for |
Water jets, pressure washing or continuous submersion |
| Certifications |
| Battery pack |
UL 1973 |
| Cells |
UL 1642, UL 9540A, IEC 62619:2022 |
| Internal fuse |
UL 60691 (TEX150-R1N-XBZ) |
| Other |
CE, RoHS |
| Transport |
UN 3480, Class 9 |
| Warranty |
| Warranty |
11-year limited warranty |
| Years 1–5 |
Free repair or replacement |
| Years 6–11 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase; keep proof of purchase |
Epoch C12460A User Manual
Epoch C12460A Spec Sheet
Epoch C12460A Data Sheet