The Epoch Batteries 12V 460Ah (5.89kWh) LiFePO4 Battery Builds a User-Serviceable 400A Class T Fuse Into a Victron-Ready 12V Battery
The Epoch C12460A-A is the V2-T Elite Series version of Epoch's 12V 460Ah battery: 12.8V nominal and 460Ah, for 5,888Wh (5.89kWh) of nominal stored energy in one 97.55 lb case. Epoch says the T refers to the integrated Class T fuse, a user-serviceable 400A Eaton Bussmann JJN-400 that reduces fault energy at the battery outlet.
It's built for professional marine, RV and stationary energy-storage systems: marine house banks on yachts, workboats and large cruising boats, RVs with large 12V inverters and solar charging, off-grid cabins and backup power. It is a deep-cycle battery, not cranking-rated.
Epoch Batteries 12V 460Ah (5.89kWh) LiFePO4 Battery Features
User-Serviceable 400A Class T Fuse
The Eaton Bussmann JJN-400 is rated 400A, 160V DC, with a 20kA interrupting rating at 160V DC. If it operates, the battery output stays off until the fuse is replaced. Correct the cause of the fault first, then fit the same type and rating with the system isolated. The fuse does not replace a main fuse or DC-rated breaker close to the battery positive for your downstream wiring.
Native Victron CAN Communication
Using the included communication harness with its RJ45 Victron cable, the battery connects at 500 kbit/s to the BMS-CAN port of a Cerbo GX or Ekrano GX, or to VE.CAN 1 or 2 on a Cerbo GX MK2. With DVCC on and Epoch set as the controlling BMS and battery monitor, the BMS publishes its charge limits and state of charge so the GX device manages charging.
180.67W Internal Heater for Cold-Weather Charging
At 0°C (32°F) the BMS low-temperature cut-off pauses charging and sends incoming charge current to the internal heating pads. The heater switches on below 5°C (41°F) and off at 10°C (50°F), and charging resumes automatically once the battery reaches 5°C. Heating runs on a connected, operating charger and never uses stored battery energy.
IP67 With All Seals and Plugs Installed
Per IEC 60529, the enclosure is dust-tight and rated for temporary immersion to 1 m for 30 minutes, but only with all seals, glands and port plugs installed. Install it in a clean, dry location away from bilge water and standing water, and remove it from service after any immersion until it has been evaluated. Do not submerge or pressure-wash it.
230A Continuous Discharge, 210A Continuous Charge
Epoch's verified continuous ratings at 25°C are 230A discharge and 210A charge. At 12.8V, 230A is about 2,944W DC before inverter losses, which Epoch says commonly suits 2,500W to 3,000W class 12V inverters with proper cabling, fusing and load management. The 500A peak applies for up to 10 seconds only.
Bluetooth Through the State of Charge Meter
The included State of Charge meter shows state of charge, voltage and current, and houses the Bluetooth 4.0 module for the free Epoch Cloud app (iOS and Android). The app shows state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts, so no separate shunt is needed for basic battery visibility.
3,500+ Cycles and an 11-Year Limited Warranty
Epoch rates it for more than 3,500 cycles to 70% capacity (25°C, 0.5C charge, 1C discharge, 70% DoD), with no watering or acid service. It's backed by an 11-year limited warranty: free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11.
Real-World Applications
Marine house banks. Run electronics and accessory loads on yachts, workboats and large cruising boats, in a compartment protected from bilge water, salt spray and direct terminal exposure.
RV and conversion house power. Pair it with a large 12V inverter and solar charging. For alternator charging, Epoch highly recommends a DC-to-DC charger programmed for LiFePO4.
Trolling motors. Power 12V trolling motors, or 24V and 36V motors through matched series banks, where the motor's current draw stays within the battery ratings.
Off-grid and backup storage. Grow to 16 in parallel for up to 7,360Ah and 94.2kWh. Epoch's planning estimates use 80% of nominal energy (about 4,710Wh): about 9.4 hours at a 500W DC load, before inverter losses.
How It Compares to Common Alternatives
Versus several smaller batteries. Epoch designed it to replace multiple smaller batteries with one 20.86 x 8.65 x 12.06 in case and one BMS, with the Class T fuse built in at the battery outlet.
Versus the standard V2 Elite. The T in V2-T refers to the integrated, user-serviceable Class T fuse. Similar-sized Epoch batteries can use different BMS current limits, apps, heaters and bank configurations, so confirm the label reads C12460A-A before you use these settings.
Versus lead-acid or AGM. It is not a drop-in replacement for every lead-acid or AGM installation, so verify fit, cabling, protection and charger profile first. Never mix it with lead-acid batteries in a bank.
Is This 12V Battery the Right Fit
-
Series or parallel, not both. Up to 4 in series (48V class) or up to 16 in parallel, using matched C12460A-A batteries of similar age, condition and firmware at the same state of charge. Series-parallel banks are not supported.
-
Charger settings. CC/CV LiFePO4 profile, 14.2V absorption for 15 minutes per battery in the bank, 13.5V float, termination at 0.02C (9.2A), equalization and temperature compensation disabled. Keep all charge sources combined at or below 210A, and stay under the 14.52V maximum charge voltage.
-
Cold charging. Charging is rated from 0°C to 50°C (32°F to 122°F) with heating. Keep the charger on and supplying current, and expect little or no charge current while the cells warm.
-
Fit and weight. 20.86 x 8.65 x 12.06 in (529.8 x 219.8 x 306.3 mm) and 97.55 lb (44.25 kg). Secure it upright with restraints rated for its weight before landing any conductor. Epoch offers a battery tray sized for this model as an accessory.
-
Installation. Torque the M8 bolts to 12 N·m (8.85 lb·ft), install a main fuse or DC-rated breaker close to the battery positive, and use precharge or soft-start for large inverters where required.
This may be a good fit if
- You run a 2,500W to 3,000W class 12V inverter
- You want a serviceable Class T fuse at the battery
- You use a Victron Cerbo GX, Ekrano GX or Cerbo GX MK2
- You need to charge in freezing weather
Common Questions
Is the Battery ABYC Compliant?
ABYC compliance is assessed for the complete vessel installation, not the battery alone. Epoch's manual lists ABYC E-11, ABYC E-13 and U.S. Coast Guard requirements, where applicable, as the marine reference set.
Will It Charge When I'm Camping in Freezing Weather?
Yes, as long as a LiFePO4 charger is connected and supplying current. Charging pauses at 0°C while the heater warms the cells, then resumes automatically at 5°C.
What if CAN Communication Is Lost?
Program every MultiPlus, Quattro and other charge source with Epoch's settings so charging stays within limits. The BMS keeps monitoring the cells and switches charging or discharging off to protect them.
How Should I Store It?
Store it clean and dry at 0°C to 35°C (32°F to 95°F), with loads and chargers disconnected. Check the state of charge at least every 3 months, since the warranty excludes batteries left uncharged for more than three months.
What's Included
- 1 x Epoch 12V 460Ah V2-T Elite LiFePO4 Battery (C12460A-A)
- 1 x State of Charge Meter With Bluetooth
- 1 x Communication Harness With RJ45 Victron Cable
- 1 x External Power Switch
- 1 x User Manual
Class T Protection for a Large 12V House Bank
The Epoch Batteries 12V 460Ah (5.89kWh) LiFePO4 Battery pairs 5.89kWh of 12V storage with a user-serviceable Class T fuse, Victron CAN communication, internal heating and Bluetooth monitoring. If you have questions about charger settings, fusing or Victron setup, the Outbound Power team is happy to help.
Epoch C12460A-A Specifications
|
| Electrical |
| Model |
C12460A-A |
| Series |
V2-T Elite Series |
| Battery type |
Deep-cycle (not cranking-rated) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell configuration |
4S2P (230Ah cells) |
| Nominal voltage |
12.8V (3.2V per cell) |
| Nominal capacity |
460Ah (0.5C, 25°C) |
| Stored energy |
5,888Wh (5.89kWh) nominal |
| Runtime planning energy |
About 4,710Wh (80% of nominal) |
| Operating voltage range |
10.4–14.52V |
| Maximum charge voltage |
14.52V (3.63V per cell) |
| Internal resistance |
≤8 mΩ |
| Self-discharge |
≤3% per month |
| Insulation resistance |
>20 MΩ at 1,000V DC (25 ± 5°C, 50% RH) |
| Shipped state of charge |
30% ± 3% |
| Cycle life |
More than 3,500 cycles to 70% capacity |
| Cycle life conditions |
25°C, 0.5C charge, 1C discharge, 70% DoD |
| Charge and Discharge |
| Maximum continuous discharge |
230A (0.5C), verified at 25°C |
| Recommended discharge current |
230A (0.5C) |
| Peak discharge |
500A for up to 10 s |
| Continuous power at 12.8V |
About 2,944W DC (before inverter losses) |
| Maximum continuous charge |
210A (0.45C), verified at 25°C |
| Recommended charge current |
210A (0.45C) |
| Peak charge |
300A for up to 5 s |
| Series connection |
Up to 4 batteries (48V class) |
| Parallel connection |
Up to 16 batteries |
| Maximum parallel bank |
7,360Ah / 94.2kWh |
| Series-parallel |
Not supported |
| Recommended Charge Settings |
| Charge profile |
CC/CV LiFePO4, no equalization |
| Bulk / absorption voltage |
14.2V |
| Absorption time |
15 min per battery in the bank |
| Float voltage |
13.5V |
| Charge termination (CC/CV) |
Current ≤0.02C (9.2A) |
| Maximum continuous charge current |
210A (0.45C), all sources combined |
| Equalization |
Disabled |
| Temperature compensation |
Disabled (0 mV/°C) |
| Victron systems |
DVCC on; controlling BMS and battery monitor set to Epoch |
| Alternators |
DC-to-DC charger programmed for LiFePO4, highly recommended |
| Temperature |
| Charge (with heating) |
0 to 50°C (32 to 122°F) |
| Low-temperature charge cut-off |
0°C (32°F); released at 5°C (41°F) |
| Heater power |
180.67W at 14.6V DC |
| Heater on (charging) |
Below 5°C (41°F) |
| Heater off (charging) |
10°C (50°F) |
| Heater power source |
Connected charger, never stored battery energy |
| Discharge |
−20 to 50°C (−4 to 122°F) |
| Storage, up to 1 month |
−20 to 45°C (−4 to 113°F) |
| Storage, recommended |
0 to 35°C (32 to 95°F), up to 1 year |
| Rated atmospheric pressure |
86–106 kPa |
| Cooling |
Passive (convection) |
| BMS and Protection |
| Overcharge |
3.63 ± 0.02V per cell (14.52V) |
| Overcharge release |
3.45 ± 0.01V per cell (13.8V) |
| Over-discharge |
2.6 ± 0.01V per cell |
| Over-discharge release |
2.8 ± 0.01V per cell |
| Charge over-current |
300 ± 2A for 5 s; released by powering off |
| Discharge over-current |
Disconnects above the peak ratings; released by switching off and on |
| Short circuit |
400A Class T fuse; replace the fuse to restore output |
| High temperature |
55°C, charge and discharge; release 53°C |
| Low temperature, charge |
0°C (with heating); release 5°C |
| Low temperature, discharge |
−20°C; release −17°C |
| Standby current |
≤50mA active or in error; ≤400µA shut down |
| Class T fuse |
Eaton Bussmann JJN-400, 400A, user-serviceable |
| Class T fuse voltage rating |
160V DC / 300V AC |
| Class T fuse interrupting rating |
20kA at 160V DC |
| After the fuse operates |
Correct the fault, then replace with the same type and rating |
| Communication and Monitoring |
| Bluetooth |
Bluetooth 4.0 in the State of Charge meter |
| State of Charge meter display |
State of charge, voltage and current |
| App |
Epoch Cloud (iOS and Android) |
| CAN bus |
500 kbit/s; daisy-chained, no branches or tees |
| GX connection, Cerbo GX or Ekrano GX |
Grey RJ45 plug to the BMS-CAN port |
| GX connection, Cerbo GX MK2 |
VE.CAN 1 or 2 at 500 kbit/s |
| Victron GX settings |
DVCC on; controlling BMS and battery monitor set to Epoch |
| Bank roles |
Battery #01 is the Master; all others are Members |
| DIP switches |
8 (Master, last battery, series string, position) |
| Controls |
External power switch included |
| Size and Weight |
| Dimensions (L x W x H) |
20.86 in x 8.65 in x 12.06 in (529.8 x 219.8 x 306.3 mm) |
| Weight |
97.55 lb (44.25 kg) |
| Terminals |
M8 bolts |
| Terminal torque |
12 N·m (8.85 lb·ft) |
| Mounting orientation |
Upright |
| Battery tray |
Offered by Epoch as an accessory |
| Case material |
PC + ABS, UL94 V-0 |
| Enclosure |
IP67 per IEC 60529, dust-tight |
| Water protection |
Temporary immersion to 1 m for 30 min |
| IP67 condition |
All seals, glands and port plugs installed |
| After any immersion |
Remove from service until evaluated |
| Certifications |
| Battery pack |
UL 1973 |
| Cells |
UL 1642, IEC 62619:2022 |
| Class T fuse |
Eaton Bussmann JJN-400 (400A) |
| Internal fuse |
UL 60691 (TEX150-R1N-XBZ) |
| EMC |
FCC Part 15B, Class A |
| Other |
CE, RoHS |
| Warranty |
| Warranty |
11-year limited warranty |
| Years 1–5 |
Free repair or replacement |
| Years 6–11 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase for full coverage |
| If not registered |
Warranty period starts from the manufacturing date |
| Transfer |
Non-transferable (original purchaser only) |
Epoch C12460A-A User Manual
Epoch C12460A-A Spec Sheet
Epoch C12460A-A Data Sheet