The Epoch Batteries 48V 100Ah (5.12kWh) LiFePO4 Battery Puts a Serviceable Class T Fuse, Victron CAN and Self-Heating in One IP67 Case
The Epoch C48100A-A is the V2-T version of Epoch's 48V 100Ah Elite: a 51.2V nominal, 100Ah lithium iron phosphate battery that stores 5,120Wh (5.12kWh). A user-serviceable 250A Eaton Class T fuse sits behind a sealed top service panel, while the 48V 100Ah V2 Elite (model C48100A) has a built-in fuse instead and its own manual.
It's made for native 48V off-grid solar, home backup, marine, RV and Victron inverter/charger systems. It is rated for 80A continuous charge and discharge, connects in parallel only, and is a deep-cycle battery, not for engine starting.
Epoch Batteries 48V 100Ah (5.12kWh) LiFePO4 Battery Features
User-Serviceable 250A Class T Fuse
The fuse improves source protection at the battery, and because it sits behind a sealed top service panel, a fuse that opens can be replaced without opening the case. If a dead short or severe fault opens it, the battery is not ruined. Shut the system down, have a qualified installer inspect it and correct the fault, then fit the correct 250A Eaton Class T fuse and refit the panel with its seal.
Native Victron CAN Communication
Using the included Victron communication harness, the battery connects to a Cerbo GX, Ekrano GX or Cerbo GX Mk2 over CAN bus at 500 kbit/s. With DVCC on and Epoch set as the controlling BMS and battery monitor, it reports its status and sets the charge voltage and current limits of your Victron chargers.
Self-Heating From Incoming Charge Current
LiFePO4 cells must not be charged below 0°C (32°F). When the battery is too cold to accept charge, the BMS uses incoming charge current to power the internal heating pads first, then allows normal charging once the cells reach a safe temperature. Charging is supported from -30°C (-22°F) ambient when charge current is available.
IP67 Enclosure With Seals and Glands Installed
The enclosure is dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes, with all seals and glands installed. It is not rated for water jets, pressure washing or continuous submersion, so install it where it stays dry in normal use, with every harness connector fully seated.
80A Continuous Charge and Discharge
Epoch rates it for 80A maximum continuous discharge, about 4,096W DC at 51.2V before inverter losses, with 250A for up to 10 seconds for surges. Charging is limited to 80A continuous from all sources combined, with up to 90A for 5 seconds. These limits apply to each battery, so add batteries in parallel if your inverter's continuous DC input can exceed 80A.
Bluetooth Monitoring for Each Battery and the Bank
The included battery gauge shows state of charge, voltage and current, and connects over Bluetooth to the free Epoch Cloud app (iOS and Android). The app adds temperature, cycles and alerts for each battery and for the bank, and a bank of matching batteries can be monitored from one dashboard.
3,500+ Cycles and an 11-Year Limited Warranty
Epoch rates it for 3,500+ cycles to 70% capacity, with no watering or equalizing. It's backed by an 11-year limited warranty with free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11.
Real-World Applications
Off-grid solar and home backup. Start with one 5.12kWh battery and grow to 16 in parallel for 1,600Ah and 81.92kWh at 51.2V.
Victron inverter/charger systems. Pair it with a MultiPlus or Quattro and a compatible GX device, with DVCC on.
Marine house power. Epoch lists marine house power and electric propulsion support, with the battery mounted where it stays dry in normal use.
RV, van and overland 48V systems. Install it upright and secure it with a hold-down or the optional bracket so it cannot slide or tip.
Runtime planning. Epoch plans runtime on about 4,096Wh, 80% of nominal energy, for a new, fully charged battery and a constant DC load: about 8.2 hours at 500W, 4.1 hours at 1,000W and 1.4 hours at 3,000W.
How It Compares to Common Alternatives
Versus the 48V 100Ah V2 Elite (C48100A). The V2 has a built-in fuse instead of a user-serviceable Class T fuse, and each model has its own manual, so check the label before you use these settings.
Versus a series-wired 48V bank. This battery is native 48V, so it never goes in series, and series-parallel is not supported either. Capacity grows by adding matched batteries in parallel, up to 16.
Versus a Group 8D lead-acid battery. Epoch gives no BCI group size, so confirm tray fit, hold-down and lid clearance first, and leave room above the terminals for cables and the top service panel. It needs no watering, and lead-acid equalization, desulfation or repair modes must not be used on it.
Is This 48V Battery the Right Fit
-
Parallel only. Up to 16 matched C48100A-A batteries of the same age, capacity and state of charge, with the DIP switches set per Epoch's V2-T Elite Series DIP Switch Guide. Update each battery's firmware on its own before building the bank, and never connect it in series.
-
Charger settings. Lithium (LiFePO4) CC/CV, 56.8V absorption for at least 15 minutes per battery in the bank, 54.0V float, equalization and temperature compensation disabled, and 80A maximum continuous per battery from all sources combined. Never charge above 58.0V. Program every charge source, Victron included, in case CAN communication is lost.
-
Cold charging. Self-heated charging needs charge current, so keep the charge source on and expect a delay before the state of charge starts to rise.
-
Fit and weight. 20.86 x 8.65 x 12.06 in (529.8 x 219.8 x 306.3 mm) including terminal posts, and 97 lb (44 kg). Lift with two people and install it upright. The optional Epoch V2 & V2-T mounting bracket (8D) fastens to threaded inserts on the case and is sold separately.
-
Protection and torque. The Class T fuse does not replace a main disconnect or a DC-rated fuse or breaker in the positive conductor, as close to the battery as practical. Torque the M8 bolt terminals to 12 N·m (8.85 lb-ft), following the product label.
This may be a good fit if
- You're building or expanding a native 48V system
- You want a fuse you can replace without opening the case
- You use a Victron Cerbo GX, Ekrano GX or Cerbo GX Mk2
- You need to charge in freezing weather
Common Questions
What Size Inverter Can One Battery Support?
Epoch estimates DC input current as AC load divided by (51.2V x inverter efficiency). A 2,000W load through a 90%-efficient inverter draws about 43A, within the 80A rating. A 4,000W load draws about 87A, so it needs at least two batteries in parallel.
Can I Wire Two in Series for a 96V System?
No. It is a native 48V battery and must never be connected in series. Connect up to 16 matched batteries in parallel to add capacity at 51.2V nominal.
How Should I Store It?
Switch the battery off, disconnect loads and chargers, and store it at 0 to 35°C (32 to 95°F) for up to 1 year, or at -20 to 45°C (-4 to 113°F) for up to 1 month.
What's Included
- 1 x Epoch 48V 100Ah V2-T Elite LiFePO4 Battery (C48100A-A)
- 1 x Battery Gauge (Bluetooth Monitoring)
- 1 x Mountable External Power Button
- 1 x Victron Communication Harness
Serviceable Protection for Native 48V Systems
The Epoch Batteries 48V 100Ah (5.12kWh) LiFePO4 Battery gives a native 48V system 5.12kWh in one IP67 case, with a user-serviceable Class T fuse, Victron CAN communication, self-heating and Bluetooth monitoring. If you have questions about charger settings, Victron setup or sizing a parallel bank, the Outbound Power team is happy to help.
Epoch C48100A-A Specifications
|
| Electrical |
| Model |
C48100A-A |
| Series |
V2-T Elite Series |
| Battery type |
Deep-cycle (not for engine starting) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell configuration |
16S1P |
| Nominal voltage |
51.2V |
| Nominal capacity |
100Ah |
| Stored energy |
5,120Wh (5.12kWh) nominal |
| Runtime planning energy |
About 4,096Wh (80% of nominal) |
| Operating voltage range |
41.6–58.0V |
| Maximum charge voltage |
58.0V (never exceed) |
| Cycle life |
3,500+ cycles to 70% capacity |
| Charge and Discharge |
| Maximum continuous discharge |
80A |
| Continuous power at 51.2V |
About 4,096W DC (before inverter losses) |
| Peak discharge |
250A for up to 10 s |
| Maximum continuous charge |
80A, all sources combined |
| Maximum short-duration charge |
90A for up to 5 s |
| Current limits |
Apply to each battery |
| Series connection |
Not supported (native 48V battery) |
| Parallel connection |
Up to 16 batteries |
| Maximum parallel bank |
1,600Ah / 81.92kWh at 51.2V nominal |
| Series-parallel |
Not supported |
| Recommended Charge Settings |
| Charger type |
Lithium (LiFePO4) compatible, CC/CV |
| Bulk / absorption voltage |
56.8V (every charge source, Victron included) |
| Absorption time |
At least 15 min per battery in the bank (60 min for four) |
| Float voltage |
54.0V |
| Equalization |
Disabled |
| Temperature compensation |
Disabled (0 mV/°C) |
| Charge current |
80A max. continuous per battery, all sources combined |
| Short-duration charge |
Up to 90A for up to 5 s |
| Maximum voltage |
Never charge above 58.0V |
| Victron DVCC |
Battery sets the charge voltage and current limits |
| Solar charge controllers |
Same voltages; Victron solar chargers follow DVCC limits |
| Alternators |
DC-DC charger, or alternator regulator set up for lithium |
| Temperature |
| Charge (cell temperature) |
0 to 55°C (32 to 131°F) |
| Self-heated charging (ambient) |
From −30°C (−22°F) when charge current is available |
| Heating power |
Incoming charge current |
| Discharge |
−20 to 55°C (−4 to 131°F) |
| Storage, up to 1 year |
0 to 35°C (32 to 95°F) |
| Storage, up to 1 month |
−20 to 45°C (−4 to 113°F) |
| BMS and Protection |
| BMS protection |
Overcharge, over-discharge, over-current, short circuit, high and low temperature |
| Class T fuse |
250A Eaton Class T, user-serviceable |
| Fuse location |
Behind a sealed top service panel |
| Fuse replacement |
Correct specified 250A Eaton Class T; refit the panel with its seal |
| Downstream protection |
Required: DC-rated fuse or breaker near the battery positive |
| Also required |
Main disconnect and correctly sized cables |
| Communication and Monitoring |
| Bluetooth |
Through the included battery gauge |
| Battery gauge display |
State of charge, voltage and current |
| App |
Epoch Cloud (iOS and Android), free |
| App data |
State of charge, voltage, current, temperature, cycles, alerts |
| Bank monitoring |
Each battery and the bank, from one dashboard |
| CAN bus |
500 kbit/s |
| Victron GX devices |
Cerbo GX, Ekrano GX, Cerbo GX Mk2 |
| GX port, Cerbo GX or Ekrano GX |
BMS-CAN |
| GX port, Cerbo GX Mk2 |
VE.Can 1 or 2, set to 500 kbit/s |
| Bank communication |
RJ45 daisy chain, black port to next blue port; no branches or tees |
| DIP switch settings |
Per the V2-T Elite Series DIP Switch Guide |
| Controls |
Mountable external power button included |
| Bank power-on |
From the Master battery |
| Size and Weight |
| Dimensions (L x W x H) |
20.86 in x 8.65 in x 12.06 in (529.8 x 219.8 x 306.3 mm) |
| Height note |
Includes terminal posts |
| Weight |
97 lb (44 kg) |
| Terminals |
M8 bolts |
| Terminal torque |
12 N·m (8.85 lb-ft), per the product label |
| Mounting orientation |
Upright |
| Mounting bracket |
Epoch V2 & V2-T mounting bracket (8D), sold separately |
| Mounting points |
Threaded inserts on the case |
| Case material |
PC + ABS, UL94 V-0 |
| Enclosure |
IP67, dust-tight, with all seals and glands installed |
| Water protection |
Temporary immersion to 1 m for 30 min |
| Not rated for |
Water jets, pressure washing or continuous submersion |
| Certifications |
| Cells |
UL 1642, UL 9540A, IEC 62619:2022 |
| Internal fuse |
UL 60691 |
| Transport |
UN 38.3 |
| Warranty |
| Warranty |
11-year limited warranty |
| Years 1–5 |
Free repair or replacement |
| Years 6–11 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase, or keep proof of purchase, to confirm the coverage start date |
Epoch C48100A-A User Manual
Epoch C48100A-A Spec Sheet
Epoch C48100A-A Data Sheet