The Rich Solar Dual Cable Entry Housing Seals Two Solar Cables Through Your Roof With IP68-Rated PG7 Glands
The Rich Solar Dual Cable Entry Housing gives two solar cables a clean, sealed path through a roof. Two PG7 cable glands come pre-installed, and each seals around one cable with an outside diameter of 4.0 to 6.2 mm (0.157 to 0.244 in).
Rich Solar designed it for RV, marine and off-grid solar systems. Choose black (RS-G06B) or white (RS-G06W). The flame-retardant polypropylene housing measures 5.9 x 4.3 x 1.6 inches (150 x 109 x 41 mm) and weighs 0.18 lb.
Rich Solar Dual Cable Entry Housing Features
IP68 PG7 Glands Tested at 2 Meters
Each PG7 gland is rated IP68 and tested at a water depth of 6.56 ft (2 m) for 30 minutes. The glands are polyamide 6 (PA6) with a UL 94 V-2 flammability rating, TÜV and CE compliance, and an operating range of -4°F to 212°F (-20°C to 100°C).
Two Separate Cable Entries
Single-hole seals give each cable its own gland, so positive and negative runs stay secure and organized as they enter the roof.
Black or White Housing
Pick the color that suits your roof. Both versions use flame-retardant polypropylene rated from -40°F to 185°F (-40°C to 85°C).
Real-World Applications
RV roofs. Bring two panel cables into the coach through one low housing.
Boats. Bring solar cables inside with each one sealed in its own gland.
Off-grid systems. Route array cables indoors at a single, tidy entry point.
Practical Comparison
Gland Housing Versus a Pre-Wired Entry Plate
A pre-wired entry plate arrives with its own wires and connectors, which fixes the wire gauge and length for you. This housing has only the two glands, so you route the solar cables you already use, as long as each one measures 4.0 to 6.2 mm across.
Buyer Guidance
Check Your Cable Diameter and Mounting
Measure the outside diameter of each cable before you order; the glands fit 4.0 to 6.2 mm (0.157 to 0.244 in). The housing mounts with adhesive or sealant and screws, and the mounting hardware and sealant aren't included.
This May Be A Good Fit If
- You're running two solar cables into an RV, boat or off-grid building
- Each cable measures 4.0 to 6.2 mm across
- You want IP68-rated glands at the entry
- You'd like a black or white housing to suit your roof
Common Questions
What Size Cable Fits the Glands?
Cables with an outside diameter of 4.0 to 6.2 mm (0.157 to 0.244 in), one cable per gland.
Are Sealant and Screws Included?
No. Mounting hardware and sealant aren't included.
What Is the Difference Between RS-G06B and RS-G06W?
Color. RS-G06B is black and RS-G06W is white, with the same specifications.
What's Included
- 1 x Dual Cable Entry Housing With 2 Pre-Installed PG7 Cable Glands (Black or White, by Option)
Two Sealed Entries in One Low Housing
The Rich Solar Dual Cable Entry Housing gives two solar cables their own IP68-rated PG7 glands in a flame-retardant housing, in black or white. If you'd like help checking your cable size or planning the roof entry, the Outbound Power team is happy to help.
Rich Solar Dual Cable Entry Housing With IP68 PG7 Glands Specifications
|
| Model |
RS-G06B (Black), RS-G06W (White) |
| General |
| Product Type |
Solar double cable entry gland |
| Number of Cable Entries |
2 |
| Housing Material |
Flame-retardant polypropylene (PP) |
| Operating Temperature |
-40°F to 185°F (-40°C to 85°C) |
| Dimensions (L x W x H) |
5.9 x 4.3 x 1.6 in (150 x 109 x 41 mm) |
| Weight |
0.18 lb |
| Mounting Method |
Adhesive/sealant and screws |
| Mounting Hardware and Sealant |
Not included |
| PG7 Cable Glands |
| Compatible Cable Outside Diameter |
0.157-0.244 in (4.0-6.2 mm) |
| Cable Gland Material |
Polyamide 6 (PA6) |
| Material Flammability Rating |
UL 94 V-2 |
| Sealing Design |
Single-hole seal |
| Ingress Protection |
IP68 |
| IPX8 Test Conditions |
6.56 ft (2 m) water depth for 30 minutes |
| Operating Temperature |
-4°F to 212°F (-20°C to 100°C) |
| Certifications / Compliance |
TÜV / CE |