EMP Shield Radio EMP Protection Up To 1500 Watts Puts An Inline EMP And Lightning Protector On Stations Up To 1,500 Watts
The EMP Shield Radio EMP Protection Up To 1500 Watts covers HF, VHF and UHF radio systems running as much as 1,500 watts. It installs in the coax through ports labeled IN and OUT, and it has a labeled GND stud for grounding. EMP Shield builds its radio protectors for radios, transceivers, base stations and antennas facing EMP, lightning and electrical surges.
EMP Shield's radio line comes in 200, 500, 1000 and 1500 watt ratings, and this page covers the 1500 watt units. Two connector options are offered: ANT-1500-N with N connectors in a blue body, and ANT-1500-UHF with UHF connectors. The power rating stays at 1,500 watts with either choice.
EMP Shield Radio EMP Protection Up To 1500 Watts Features
A 1500 Watt Rating For Stations Above 1000 Watts
Stations that run above 1,000 watts are past the limit of the 1000 watt unit. This model raises the ceiling to 1,500 watts, so those setups still get an inline protector on the coax.
E1, E2 And E3 Coverage Plus Lightning And Surges
EMP Shield says its technology protects against each phase of an EMP (E1, E2 and E3). The company also lists coronal mass ejections, lightning and power surges as threats it addresses.
Fast Shunting Of Over-Voltage
EMP Shield states the unit begins shunting over-voltage in less than one nanosecond, drawing the surge off the line before it reaches the radio connected behind it.
N Or UHF Connectors
The N version, ANT-1500-N, has N connectors and a blue housing. The UHF version, ANT-1500-UHF, has UHF connectors. Choosing the version that matches your coax keeps the hookup straightforward.
Labeled Connections And Ground Stud
On the N version, the label reads IN and OUT at the two connectors and GND above the ground stud, along with the model number Ant-1500-N. That makes it easy to confirm the rating before installation.
Testing And Listing As EMP Shield States
EMP Shield states that it tested at Keystone Compliance to MIL-STD-188-125-1, MIL-STD-461G, MIL-STD-464C and RS-105, and it points out that Keystone Compliance does not endorse products. EMP Shield says its products are listed by the Department of Homeland Security in an EMP resilience report. The veteran-owned company builds its units in Kansas, USA.
Real-World Applications
Ham Stations Above 1000 Watts. If your station runs between 1,000 and 1,500 watts, this rating keeps an EMP Shield protector in the line where a smaller model would be under-rated.
Base Stations And Antenna Systems. EMP Shield names base stations and antennas among the equipment this line protects. A 1500 watt rating suits fixed installations at that power.
Critical Communication Systems. EMP Shield designs the radio protectors for the critical communication systems that first responders and emergency communications specialists rely on to stay connected.
Practical Comparison
The 1500 Watt Model Versus The 1000 Watt Model
The connector choices are the same. The 1000 watt unit is limited to 1,000 watts. If your station can exceed that, the 1500 watt model is the one rated for it.
Inline Radio Protection Versus A Faraday Cage
A Faraday cage is a way to store spare radios while they're sealed and unplugged. It can't protect a station that's connected and on the air. This unit stays in the coax, so your operating station keeps its protection.
The 1500 Watt Unit Versus A Whole-Home Panel Unit
A whole-home panel unit covers the wiring that runs from your breaker panel. The antenna coax is a separate path into your radio, and this unit is the piece that protects it.
Buyer Guidance
When The 1500 Watt Rating Makes Sense
Choose this model when your station's maximum output is above 1,000 watts and no more than 1,500 watts. Lower power is also within its rating, so it can serve a station that may grow into that range later.
Choosing N Or UHF And Installing
Pick ANT-1500-N for coax with N connectors or ANT-1500-UHF for coax with UHF connectors. Install it inline at the IN and OUT ports, make the ground connection at the GND stud, and use EMP Shield's instructions for the radio models.
This May Be A Good Fit If
- Your station runs above 1,000 watts, up to 1,500 watts
- Your coax ends in N or UHF connectors
- You want protection that stays on the line in use
- You run a high-power base or ham station
Common Questions
What Is Different Between ANT-1500-N And ANT-1500-UHF?
The connector type and the model number. The N version has N connectors in a blue housing, and the UHF version has UHF connectors. EMP Shield rates both for up to 1,500 watts.
Should I Choose 1500 Watts If My Station Runs 900 Watts?
The 1000 watt model already covers a 900 watt station. The 1500 watt model works as well and leaves room if you plan to add power.
How Is The Unit Grounded?
The housing has a threaded GND stud for the ground connection. EMP Shield's installation instructions show how to make it.
What Warranty Applies?
EMP Shield provides a 10-year limited warranty on defects in materials and workmanship, and it repairs or replaces covered units. For a unit destroyed by lightning, EMP Shield offers a $50 replacement in exchange for the destroyed unit. Its separate protection policy can reimburse damaged connected electronics up to $25,000 once its conditions are satisfied.
What's Included
- 1 x EMP Shield HF/VHF/UHF Radio EMP Protection Unit Up To 1500 Watts (N Or UHF Connectors As Selected)
Coax Protection For Stations Up To 1,500 Watts
The EMP Shield Radio EMP Protection Up To 1500 Watts gives high-power stations an inline protector on the coax, with N or UHF connectors. The Outbound Power team can help you confirm the rating and connector before you order.
EMP Shield HF/VHF/UHF Radio EMP Protection Up To 1500 Watts Specifications
|
| Model |
| Product |
HF/VHF/UHF Radio EMP Protection |
| Model, UHF connectors |
ANT-1500-UHF |
| Model, N connectors |
ANT-1500-N |
| Catalog model numbers |
ANT/1500/N |
| Radio line ratings |
200, 500, 1000, 1500 watts |
| Electrical |
| Power rating |
Up to 1500 watts |
| Radio systems |
HF, VHF, UHF |
| Connectors, UHF option |
UHF (SO-239 style), IN and OUT |
| Connectors, N option |
N, IN and OUT |
| Ground |
Threaded GND stud |
| Protection |
| Threats (per EMP Shield) |
EMP (E1, E2, E3), CME, solar flares, lightning, power surges |
| Response (per EMP Shield) |
Begins shunting over-voltage in less than 1 nanosecond |
| Testing (per EMP Shield) |
Keystone Compliance, MIL-STD-188-125-1, MIL-STD-461G, MIL-STD-464C, RS-105 |
| RS-105 test levels (per EMP Shield) |
50 kV/m and 90 kV/m |
| DHS listing (per EMP Shield) |
EMP resilience report |
| Physical |
| Housing color, N option |
Blue |
| Label markings |
Model, IN, OUT, GND, Patented |
| Made in |
Kansas, USA |
| Company |
Veteran owned |
| Warranty |
| Limited warranty (EMP Shield) |
10 years, defects in materials and workmanship |
| Remedy |
Repair or replacement |
| Unit destroyed by lightning |
Replaced for $50 with the destroyed unit |
| Connected equipment policy |
Up to $25,000, EMP Shield conditions apply |