The Epoch Batteries 12V and 36V 10A Lithium Battery Charger Charges a 12V House Battery and a 36V Trolling Motor Battery While the Engine Runs
The Epoch CHG-DC-12V36V is a two-bank, non-isolated marine DC-to-DC charger. It draws from a compatible 12V or 24V starter-battery system (13–30VDC input) and runs two independent outputs, 12V / 10A and 36V / 10A, for about 480W of nominal output before conversion losses.
It's made for bass boats that carry a 12V starter battery, a separate 12V electronics or house battery and a native 36V trolling motor battery, so the outboard's charging system can support both auxiliary banks.
Epoch Batteries 12V and 36V 10A Lithium Battery Charger Features
Two Independent Output Banks
The 12V / 10A bank charges a separate electronics, house or secondary battery, and the 36V / 10A bank charges a compatible trolling motor battery. Each bank charges and finishes on its own.
Automatic Voltage-Sensing Start and Stop
With a 12V source, charging starts above 13.8V and stops below 13.0V. With a 24V source, it starts above 26.8V and stops below 25.2V. After about 20 idle minutes the charger hibernates while it keeps monitoring source voltage.
Battery Modes and BMS Activation for Each Bank
Each bank has its own MODE control for LiFePO4, lead-acid or AGM. Select the mode before charging; to change it, disconnect that bank's output ring terminals first. For a compatible sleeping LiFePO4 battery, hold that bank's MODE button for about three seconds to wake the BMS.
IP67 Epoxy-Filled Enclosure With Active Cooling
Pure epoxy filling gives the enclosure an IP67 rating. It isn't fanless. The aluminum housing and bottom cooling plate work with a waterproof cooling fan, so keep more than 30mm of clearance.
Built-In Protection and a 2-Year Warranty
Short-circuit, reverse-connection, overcharge and overtemperature protection are built in, and the charger carries a 2-year limited warranty covering free repair or replacement.
Real-World Applications
Bass boats. Charge a 12V electronics battery and a native 36V trolling battery from a 12V starter system.
24V source systems. Charge separate 12V and 36V auxiliary batteries from a compatible 24V source.
Practical Comparison
Epoch CHG-DC-12V36V Versus a Plug-In AC Onboard Charger
This charger supplements energy while the source charging system is active. With 10A per bank, a short engine run may replace only part of the energy used, so a compatible AC onboard charger is still recommended for a complete dockside recharge and periodic balancing.
Epoch CHG-DC-12V36V Versus the Single-Bank CHG-DC-36V
The single-bank CHG-DC-36V charges one 36V battery from a 250 x 95 x 68 mm case. This dual model adds an independent 12V / 10A bank in a 250 x 149 x 68 mm case.
Buyer Guidance
Check Your Alternator and Wiring
Both outputs together total about 480W before losses, so input current on a 12V system can be substantial. Confirm the outboard's charging output, existing electronics load, cable size, fuse protection and voltage drop. Never loop the 12V output back to the starter battery used as the input, and don't use a 36V battery as the input source.
Install It Correctly
Mount it to a rigid surface in a protected, ventilated spot. Connect the input pair to the starter battery first, select each bank's mode, then connect the output pairs. Each red and black pair in one cable jacket must go to the same battery, and a black lead must never land on a terminal carrying red leads. Keep the ring terminals out of rain and snow, and don't submerge the charger.
This May Be A Good Fit If
- You have a 12V or 24V starter system plus separate 12V and 36V auxiliary batteries
- Your outboard has charging capacity to spare
- You still recharge fully at the dock with an AC charger
Common Questions
Does the 12V Output Charge My Starter Battery?
No. The starter battery is the input source. Use the 12V output for a separate auxiliary, house, electronics or secondary battery.
Can I Use the 36V Output on Three 12V Batteries in Series?
Epoch publishes the 36V output for one compatible 36V battery. A three-battery 12V string may need individual-bank charging and balancing under the battery maker's instructions.
Can I Charge a Frozen Lithium Battery?
No. Don't charge LiFePO4 below 0°C / 32°F unless the battery has an approved internal heater or its maker permits it.
What's Included
- 1 x Epoch CHG-DC-12V36V Dual-Output Marine DC-to-DC Charger With Pre-Wired Ring Terminal Input and Output Leads
- 1 x User Manual With Wiring Diagram
Keep Both Auxiliary Banks Charging Under Way
The Epoch Batteries 12V and 36V 10A Lithium Battery Charger turns a 12V or 24V starter system into two regulated charging sources, with automatic start and stop and an IP67 enclosure. If you'd like help planning the wiring for your boat, the Outbound Power team is happy to help.
Epoch 12V and 36V 10A Lithium Battery Charger Specifications
|
| Input |
| Supported source systems |
Compatible 12V or 24V starter-battery systems |
| DC input range |
13–30VDC |
| Unsupported input |
36V input batteries are not supported |
| 12V source start |
Above 13.8V |
| 12V source stop |
Below 13.0V |
| 24V source start |
Above 26.8V |
| 24V source stop |
Below 25.2V |
| Input current rating |
Not published |
| Output |
| Model |
CHG-DC-12V36V |
| Product type |
Two-bank, non-isolated marine DC-to-DC charger |
| Charging banks |
2 independently operating output banks |
| 12V output bank |
12V / 10A (approx. 120W) |
| 36V output bank |
36V / 10A (approx. 360W) |
| Total nominal output |
Approx. 480W before conversion losses |
| 12V output purpose |
Separate 12V auxiliary, house, electronics or secondary battery |
| 36V output purpose |
Separate compatible 36V auxiliary or trolling motor battery |
| Same-battery loopback |
Do not connect the 12V output to the starter battery used as input |
| Connections |
Pre-wired ring-terminal leads (1 input pair, 1 12V output pair, 1 36V output pair) |
| Lead colors |
Red positive, black negative |
| Isolation |
Non-isolated |
| Replacement fuse |
15A per bank |
| Charging Profile |
| 12V bank modes |
12V LiFePO4, 12V lead-acid or 12V AGM |
| 36V bank modes |
36V LiFePO4, 36V lead-acid or 36V AGM |
| Mode control |
Separate front-panel MODE controls for each bank |
| Mode-change rule |
Select before charging; disconnect that bank's output ring terminals to change |
| Lithium BMS activation |
Select LiFePO4, then hold that bank's MODE about 3 seconds |
| Idle hibernation |
After about 20 minutes, keeps monitoring input voltage |
| Manual power control |
Hold MODE 6 seconds to turn off; short-press to wake |
| Normal charge indication |
POWER solid green, CHARGING solid red |
| Full-charge indication |
POWER and CHARGING LEDs solid green |
| Cold-weather lithium charging |
Not below 0°C / 32°F unless the battery has approved heating or maker permission |
| Protection |
| Short-circuit protection |
Yes |
| Reverse-connection protection |
Yes |
| Overcharge protection |
Yes |
| Overtemperature protection |
Yes |
| Ingress protection |
IP67, enclosure filled with pure epoxy resin |
| Housing |
Aluminum housing with bottom aluminum cooling plate |
| Cooling |
Waterproof cooling fan (not fanless) |
| Working temperature |
-20°C to 40°C (-4°F to 104°F) |
| Nominal working temperature |
25°C (77°F) |
| Size and Weight |
| Dimensions |
250 x 149 x 68 mm (approx. 9.84 x 5.87 x 2.68 in) |
| Mounting holes |
6.5mm |
| Recommended fasteners |
M6 screws |
| Required clearance |
More than 30mm around the unit |
| Warranty |
| Warranty |
2-year limited warranty: free repair or replacement |
Epoch CHG-DC-12V36V User Manual