The Epoch Batteries 24V 230Ah (5.89kWh) LiFePO4 Battery Adds a Serviceable 300A Class T Fuse to Victron CAN, Self-Heating and Bluetooth
The Epoch C24230A-A is a V2-T Elite Series lithium iron phosphate battery rated at 25.6V nominal and 230Ah, for 5,888Wh of stored energy in one managed, sealed case. The V2-T design adds a user-serviceable 300A Eaton Class T fuse to native Victron CAN communication, Bluetooth monitoring through the included battery gauge, BMS-controlled internal heating and an IP67 enclosure.
It's made for marine house banks, 24V RV and mobile power, and 24V off-grid solar and backup systems, including Victron systems built around a Cerbo GX or Ekrano GX. It is a deep-cycle battery, not for engine starting.
Epoch Batteries 24V 230Ah (5.89kWh) LiFePO4 Battery Features
A User-Serviceable 300A Class T Fuse at the Source
An Eaton Bussmann JJN-300 Class T fuse, rated 300A with a 20kA interrupting rating at 160V DC, sits under a protected service cover on the lid. It reduces fault energy at the battery outlet, and if it opens it can be replaced with the same approved fuse. It does not replace a DC-rated main fuse or breaker close to the battery positive, a disconnect, or branch protection.
Native Victron CAN Communication
The battery connects to a compatible Victron GX device (Cerbo GX, Ekrano GX or Cerbo GX Mk2) over CAN at 500 kbit/s, using the included communication harness. With DVCC on and Epoch set as the controlling BMS and battery monitor, it sets the charge voltage and current limits of your Victron chargers. Batteries link in a daisy chain, with no branches or tees.
BMS-Controlled Heating for Cold-Weather Charging
The cells are never charged below 0°C (32°F). While charging, the BMS switches the 153.6W internal heater on at 5°C (41°F) and off at 10°C (50°F), using incoming charge energy to warm the cells before normal charging proceeds. Charging is rated from 0°C to 50°C (32°F to 122°F) with heating support, and discharge from -20°C to 50°C (-4°F to 122°F).
115A Continuous Charge and Discharge
At 25°C, Epoch rates it for 115A continuous discharge, about 2,944W DC at 25.6V before inverter losses, and 250A for 5 seconds. It accepts 115A of continuous charge from all sources combined, and 180A for 5 seconds. If your inverter's continuous DC input can exceed 115A, add batteries in parallel.
Bluetooth Monitoring Through the Included Gauge
The remote digital gauge shows state of charge and links over Bluetooth 4.0 to the free Epoch Cloud app for iOS and Android, within about 10 m. The app shows state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts.
IP67 Dust-Tight, Immersion-Rated Enclosure
The enclosure is dust-tight and protected against temporary immersion to 1 m for 30 minutes with all seals and glands installed. It is not rated for water jets, pressure washing or continuous submersion, so install it where it stays dry in normal use, with all harness connectors fully seated.
Listed Components and an 11-Year Limited Warranty
Epoch lists UL 1973 for the pack, UL 1642, UL 9540A and IEC 62619:2022 for the cells, and UL 60691 for the fuse component. The battery is rated for 3,500+ cycles to 70% end-of-life capacity at 25°C and backed by an 11-year limited warranty: free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11.
Real-World Applications
Marine house banks. Run electronics, refrigeration, pumps, navigation and lighting from a bank that reports to your Victron GX.
RV and mobile power. Size a 24V inverter by its DC input current. A 2,000W load through a 90%-efficient inverter draws about 87A.
24V off-grid solar and backup. Epoch's planning estimates use 80% of nominal energy (4,710Wh) for a constant DC load, before inverter losses: about 9.4 hours at 500W and 4.7 hours at 1,000W.
Practical Comparison
Epoch 24V 230Ah V2-T Elite Versus the 24V 230Ah V2 Elite
Epoch's 24V 230Ah V2 Elite (C24230A) has a built-in fuse instead of the user-serviceable Class T fuse, and it has its own manual. Choose the V2-T (C24230A-A) if you want the Class T fuse at the battery outlet.
Epoch 24V 230Ah V2-T Elite Versus a Group 8D Lead-Acid Battery
If you're replacing a Group 8D lead-acid battery, confirm tray fit, hold-down and lid clearance first. This battery needs no watering or equalizing, and lead-acid equalization, desulfation or repair modes must not be used on it.
Buyer Guidance
Charger Settings and Victron Setup
Use a lithium (LiFePO4) CC/CV profile with 28.4V bulk/absorption, 15 minutes of absorption per battery in the bank, 27.0V float, and equalization and temperature compensation disabled. Never charge above 29.0V. Set the DIP switches on every battery, and program every charge source, Victron equipment included, to these values in case CAN communication is lost. For alternators, use a DC-DC charger or a lithium alternator regulator.
Fit, Weight and Installation
The battery measures 20.86 x 8.65 x 12.06 in (529.8 x 219.8 x 306.3 mm) including terminal posts and weighs 98.9 lb (45.86 kg). Lift it with two people or a lifting aid, and install it upright on a flat, rigid surface with service access to the terminals, fuse area and ports. Threaded inserts accept the Elite Series 8D mounting hardware, sold separately. Torque the M8 terminals to 12 N·m (8.85 lbf·ft).
This May Be A Good Fit If
- You want a Class T fuse right at the battery
- You run a Victron Cerbo GX or Ekrano GX
- You need to charge in cold weather
- You plan a parallel bank or a 2-battery series string
Common Questions
What Happens if the Class T Fuse Opens?
The battery isn't ruined. Isolate every source and load, confirm the system is de-energized, and find and correct the fault. Then fit only the same Eaton Bussmann JJN-300 300A fuse and refit all covers and seals. Epoch strongly recommends qualified service.
Can I Wire These Batteries in Series?
Yes, up to 2 in series for 51.2V nominal and 58.0V at full charge, or up to 16 in parallel for 3,680Ah. Mixed series-parallel banks are not supported. Use C24230A-A batteries of the same age, capacity and state of charge.
What Happens if CAN Communication Is Lost?
The BMS still protects the battery on its own, and Bluetooth monitoring through the gauge works with or without a GX device. Your chargers fall back to their programmed settings.
How Should I Store It?
Charge it to at least 50%, switch it off and disconnect loads and chargers. Check the state of charge at least every 3 months, since the warranty does not cover a battery left uncharged for more than 3 months.
What's Included
- 1 x Epoch 24V 230Ah V2-T Elite LiFePO4 Battery (C24230A-A)
- 1 x Remote Digital Battery Gauge (Bluetooth)
- 1 x Mountable External Power Button
- 1 x Communication Harness
Protected 24V Storage Built for Victron Systems
The Epoch Batteries 24V 230Ah (5.89kWh) LiFePO4 Battery gives a 24V system 5.89kWh in one IP67 case, with a serviceable Class T fuse, Victron CAN communication, self-heating and Bluetooth monitoring. If you have questions about charger settings, Victron setup or sizing a bank, the Outbound Power team is happy to help.
Epoch C24230A-A Specifications
|
| Electrical |
| Model |
C24230A-A |
| Series |
V2-T Elite Series |
| Battery type |
Deep-cycle (not for engine starting) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell configuration |
8S1P (230Ah cells) |
| Nominal voltage |
25.6V (3.2V per cell) |
| Nominal capacity |
230Ah |
| Stored energy |
5,888Wh (5.89kWh) |
| Operating voltage range |
20.8–29.0V (planning values) |
| Maximum voltage |
29.0V |
| Minimum voltage |
20.8V |
| Over-discharge threshold |
2.60V per cell (about 20.8V) |
| Working SOC range |
0–100% |
| Internal resistance |
≤16 mΩ |
| Self-discharge |
≤3% per month |
| Cycle life |
3,500+ cycles to 70% end-of-life capacity (25°C) |
| Charge and Discharge |
| Maximum continuous discharge |
115A (25°C) |
| Peak discharge |
250A for 5 s |
| Continuous power at 25.6V |
2,944W DC (before inverter losses) |
| Maximum continuous charge |
115A (25°C), all sources combined |
| Maximum charge, short duration |
180A for 5 s |
| Series connection |
Up to 2 identical batteries |
| Two-battery series string |
51.2V nominal, 58.0V at full charge |
| Parallel connection |
Up to 16 identical batteries |
| Maximum parallel bank |
3,680Ah / 94.21kWh at 25.6V nominal |
| Series-parallel |
Not supported |
| Recommended Charge Settings |
| Charger type |
Lithium (LiFePO4) compatible, CC/CV |
| Bulk / absorption voltage |
28.4V |
| Absorption time |
15 min per battery in the bank |
| Float voltage |
27.0V |
| Equalization |
Disabled |
| Temperature compensation |
Disabled |
| Charge current |
115A max. continuous per battery |
| Maximum charge voltage |
Never above 29.0V |
| Victron GX (DVCC) |
DVCC on; controlling BMS and battery monitor set to Epoch |
| Backup programming |
Every charge source set to the same values |
| Alternator charging |
DC-DC charger or lithium alternator regulator |
| Standard charge (rating method) |
CC ≤0.5C, CV 28.8V (3.60V per cell), end at 0.02C |
| Temperature |
| Charge |
0 to 50°C (32 to 122°F), with heating support |
| Cell charging |
Not below 0°C (32°F) |
| Heater |
153.6W at 29.2V DC, BMS-controlled |
| Heater on (while charging) |
5°C (41°F) |
| Heater off (while charging) |
10°C (50°F) |
| Heater power source |
Incoming charge energy |
| Discharge |
−20 to 50°C (−4 to 122°F) |
| Storage, up to 1 month |
−20 to 45°C (−4 to 113°F) |
| Storage, up to 1 year |
0 to 35°C (32 to 95°F) |
| Cooling |
Passive convection |
| Rated atmospheric pressure |
86–106 kPa |
| BMS and Protection |
| Voltage protection |
Over-voltage and under-voltage |
| Charge over-current |
180 ± 2A, 5 s delay |
| Discharge over-current |
250 ± 2A, 5 s delay |
| Short circuit |
Class T fuse |
| Charge temperature protection |
Low 0°C (release 5°C, with heating); high 55°C (release 53°C) |
| Discharge temperature protection |
Low −20°C (release −17°C); high 55°C (release 53°C) |
| Monitoring |
Cell voltage, current, temperature, protection events, balancing |
| Class T fuse |
Eaton Bussmann JJN-300, 300A, user-serviceable |
| Fuse voltage rating |
160V DC / 300V AC |
| Fuse interrupting rating |
20kA at 160V DC |
| Fuse location |
Under a protected service cover on the lid |
| Main fuse or DC breaker |
Required near battery positive; not included |
| Communication and Monitoring |
| Bluetooth |
Bluetooth 4.0 through the included battery gauge |
| App |
Epoch Cloud (iOS and Android) |
| App data |
SOC, cell voltage, temperature, cycles, system health alerts |
| Bluetooth range |
About 10 m |
| Battery gauge |
Remote digital gauge, shows SOC (included) |
| CAN bus |
500 kbit/s; daisy-chain only, no branches or tees |
| Victron GX port |
BMS-CAN, or VE.Can at 500 kbit/s |
| Victron GX devices |
Cerbo GX, Ekrano GX, Cerbo GX Mk2 |
| Controls |
Mountable external power button (included) |
| DIP switches |
8 (battery role and bank position) |
| Size and Weight |
| Dimensions (L x W x H) |
20.86 in x 8.65 in x 12.06 in (529.8 x 219.8 x 306.3 mm) |
| Height note |
Includes terminal posts |
| Weight |
98.9 lb (45.86 kg) |
| Terminals |
M8 bolts |
| Terminal torque |
12 N·m (8.85 lbf·ft) |
| Mounting orientation |
Upright, on a flat, rigid surface |
| Mounting points |
Threaded inserts for Elite Series 8D mounting hardware |
| Mounting hardware |
Elite Series 8D mounting hardware, sold separately |
| Case material |
PC + ABS, UL94 V-0 |
| Enclosure |
IP67, dust-tight |
| Water protection |
Temporary immersion to 1 m for 30 min |
| IP67 condition |
All seals and glands installed |
| Not rated for |
Water jets, pressure washing or continuous submersion |
| Certifications |
| Battery pack |
UL 1973 |
| Cells |
UL 1642, UL 9540A, IEC 62619:2022 |
| Fuse component |
UL 60691 |
| Other |
CE, RoHS |
| Transport |
UN 3480, Class 9 |
| Warranty |
| Warranty |
11-year limited warranty |
| Years 1–5 |
Free repair or replacement |
| Years 6–11 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase; keep proof of purchase |
Epoch C24230A-A User Manual
Epoch C24230A-A Spec Sheet
Epoch C24230A-A Data Sheet