The Epoch Batteries 48V 100Ah (5.12kWh) LiFePO4 Battery Puts Victron CAN, Self-Heating and Bluetooth in One IP67 Case
The Epoch C48100A is a V2 Elite Series lithium iron phosphate battery rated at 51.2V nominal and 100Ah, for 5.12kWh of stored energy in one managed case with one BMS. It combines native Victron CAN communication, Bluetooth monitoring through the included battery gauge, internal self-heating, a UL 60691 internal fuse and an IP67 enclosure.
It's made for native 48V house-power and energy-storage systems in off-grid cabins, solar banks, RVs, vans, boats and home backup. A native 48V battery draws less current than a lower-voltage bank of the same energy, so cables can be smaller. It is a deep-cycle battery, not for engine starting.
Epoch Batteries 48V 100Ah (5.12kWh) LiFePO4 Battery Features
Native Victron CAN Communication
The battery connects to a compatible Victron GX device (Cerbo GX, Ekrano GX or Cerbo GX Mk2) over CAN bus at 500 kbit/s, using the included communication harness. With DVCC on and Epoch set as the controlling BMS and battery monitor, it reports its status and sets the charge voltage and current limits of your Victron chargers.
Self-Heating for Charging in the Cold
LiFePO4 cells must not be charged below 0°C (32°F). When a charge source is connected and the cells are too cold, the BMS holds off charging while the internal heater, powered by the charge source, warms them. Charging resumes at 5°C (41°F), and with self-heating, charging is supported from -30°C (-22°F) ambient.
IP67 Dust-Tight, Immersion-Rated Enclosure
The enclosure is dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes. It is not rated for water jets, pressure washing or continuous submersion, so install it where it stays dry in normal use, with all harness connectors fully seated.
150A Continuous and 300A Surge Discharge
Epoch rates it for 150A maximum continuous discharge, about 7,680W DC at 51.2V before inverter losses, for up to 20 minutes at 150A and not for cycling. It supplies 300A for 30 seconds for surges and accepts up to 100A continuous charge. If your inverter's continuous DC input can exceed 150A, add batteries in parallel.
Bluetooth Monitoring for Every Battery
The included mountable gauge shows state of charge and links over Bluetooth 4.0 to the Epoch Li-Ion app (iOS and Android). The app shows voltage, current, cell voltages, temperatures, history and warnings, installs firmware updates over the air, and its parallel view shows the whole bank.
Smart BMS and 270A Internal Fuse
The BMS protects against overcharge, over-discharge, over-current, short circuit and high or low temperature, backed by a 270A internal fuse (UL 60691). Epoch lists UL 1973 for the pack and UL 1642, UL 9540A and IEC 62619:2022 for the cells. The internal fuse does not replace a DC-rated fuse or breaker close to the battery positive.
3,500+ Cycles and an 11-Year Limited Warranty
Epoch rates it for 3,500+ cycles to 70% remaining capacity (25°C, 0.5C charge, 1C discharge), with no watering or equalizing. It's backed by an 11-year limited warranty with free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11.
Real-World Applications
Off-grid cabins and solar storage. Start with one 5.12kWh battery and grow to as many as 16 in parallel for 1,600Ah and 81.92kWh.
RV, overland and van systems. Pair it with a 48V inverter/charger, mounted upright and secured against vibration, and charge in freezing weather with self-heating.
Marine house power. Epoch lists marine house power and electric propulsion support, with the battery installed where it stays dry in normal use.
Home backup and heavy loads. Run large 48V inverters, mini-splits and well pumps. Epoch's planning estimates use 80% of nominal energy (4,096Wh) for a constant DC load, before inverter losses: about 8.2 hours at 500W and 4.1 hours at 1,000W.
How It Compares to Common Alternatives
Versus a 48V server rack battery. Most server rack batteries are designed for dry, climate-controlled indoor rooms. This battery adds an IP67 enclosure, self-heating, Bluetooth monitoring and Victron CAN communication for RV, marine and off-grid installs.
Versus a 12V or 24V bank of the same energy. At 51.2V nominal, it draws less current for the same power, which allows smaller cables and cleaner busbars, and the 5.12kWh sits behind one BMS.
Versus a Group 8D lead-acid battery. If you're replacing an 8D, confirm tray fit, hold-down and lid clearance first. This battery needs no watering, and lead-acid equalization, desulfation or repair modes must not be used on it.
Is This 48V Battery the Right Fit
-
Parallel only. Up to 16 in parallel with matched C48100A batteries of the same age, capacity and state of charge, with the DIP switches set for the bank. Do not connect it in series.
-
Charger settings. Lithium (LiFePO4) CC/CV, 56.8V absorption for at least 15 minutes per battery, 54.0V float, 53.2V re-bulk, equalization and temperature compensation disabled. Never charge above 58.4V. Program every charge source, Victron included, in case CAN communication is lost.
-
Cold charging. Below freezing, the heater must warm the cells before charge current flows, so expect a delay.
-
Fit and weight. 20.86 x 8.65 x 12.06 in (529.8 x 219.8 x 306.3 mm) including terminal posts, and 97 lb (approx. 44 kg). Lift with two people or a lifting aid and install it upright. The Epoch V2 & V2-T Mounting Hardware (8D battery bracket) is sold separately.
-
Installation. Epoch calls for installers who understand DC systems, lithium charging and overcurrent protection. Torque the M8 terminals to 8–12 N·m, and charge fully before first use, since it ships at about 30%.
This may be a good fit if
- You're building or expanding a native 48V system
- You use a Victron Cerbo GX, Ekrano GX or Cerbo GX Mk2
- You need to charge in freezing weather
- You want app monitoring of the whole bank
Common Questions
Will the Heater Drain the Battery Off-Grid?
No. The heater is powered by the charge source and warms the cells when a charger is connected and they are too cold to charge. Epoch says it does not use stored battery capacity to keep itself warm while the battery sits or discharges.
How Cold Can It Discharge?
Discharge is rated from -20°C to 55°C (-4°F to 131°F), with no heating needed.
What Happens if CAN Communication Is Lost?
The BMS still protects the battery on its own, and Bluetooth monitoring works with or without a GX device. Your chargers fall back to their programmed settings, which is why each one should be set to Epoch's values.
How Should I Store It?
Charge it to at least 50%, switch it off and disconnect loads and chargers. Check the state of charge at least every 3 months, since the warranty does not cover a battery left uncharged for more than 3 months.
What's Included
- 1 x Epoch 48V 100Ah V2 Elite LiFePO4 Battery (C48100A)
- 1 x Mountable Battery Gauge (Bluetooth Meter S4855SW-H)
- 1 x Gauge Connection Harness
- 1 x Mountable ON/OFF Switch
- 1 x Set of Battery and Gauge Manuals
Native 48V Storage Built for Victron and Off-Grid Systems
The Epoch Batteries 48V 100Ah (5.12kWh) LiFePO4 Battery gives a 48V system 5.12kWh in one IP67 case, with Victron CAN communication, self-heating and Bluetooth monitoring. If you have questions about charger settings, Victron setup or sizing a bank, the Outbound Power team is happy to help.
Epoch C48100A Specifications
|
| Electrical |
| Model |
C48100A |
| Series |
V2 Elite Series |
| Battery type |
Deep-cycle (not for engine starting) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell type |
Prismatic LiFePO4 |
| Cell configuration |
16S1P (100Ah cells) |
| Nominal voltage |
51.2V (3.2V per cell) |
| Nominal capacity |
100Ah (0.5C, 25°C) |
| Stored energy |
5,120Wh (5.12kWh) |
| Operating voltage range |
40.0–58.4V |
| Maximum charge voltage |
58.4V (3.65V per cell) |
| Minimum voltage |
40.0V (2.5V per cell) |
| Working SOC range |
0–100% |
| Self-discharge |
≤3% per month (100% SOC, 25°C) |
| State of charge at shipment |
30% ± 3% |
| Insulation resistance |
≥20 MΩ at 1,000V DC (25 ± 5°C, 50% RH) |
| Cycle life |
3,500+ cycles to 70% remaining capacity |
| Cycle life conditions |
25°C, 0.5C charge, 1C discharge |
| Charge and Discharge |
| Maximum continuous discharge |
150A |
| 150A discharge limit |
Up to 20 min at 150A; not for cycling |
| Peak discharge |
300A for 30 s |
| Continuous power at 51.2V |
7,680W DC (before inverter losses) |
| Maximum continuous charge |
100A |
| Maximum charge, short duration |
300A for 5 s |
| Series connection |
Not supported (native 48V battery) |
| Parallel connection |
Up to 16 batteries |
| Maximum parallel bank |
1,600Ah / 81.92kWh at 51.2V nominal |
| Recommended Charge Settings |
| Charger type |
Lithium (LiFePO4) compatible, CC/CV |
| Bulk / absorption voltage |
56.8V |
| Absorption time |
At least 15 min per battery in the bank |
| Float voltage |
54.0V |
| Re-bulk voltage |
53.2V |
| Equalization |
Disabled |
| Temperature compensation |
Disabled (0 mV/°C) |
| Charge current |
100A max. continuous per battery |
| BMS high-voltage cutoff |
58.4V |
| SOC recalibration |
58.4V (manual) |
| SOC recalibration with Victron |
Custom algorithm under Victron communication |
| Victron GX (DVCC) |
DVCC on; controlling BMS and battery monitor set to Epoch |
| Standard charge (rating method) |
CC ≤0.5C to 58.4V, CV to 0.02C, 25°C |
| Temperature |
| Charge (cell temperature) |
0 to 55°C (32 to 131°F) |
| Charge with self-heating (ambient) |
−30 to 55°C (−22 to 131°F) |
| Charging resumes after heating |
Cells at 5°C (41°F) |
| Self-heating power |
From the charge source |
| Discharge |
−20 to 55°C (−4 to 131°F) |
| Storage, up to 1 month |
−20 to 45°C (−4 to 113°F) |
| Storage, up to 1 year |
0 to 35°C (32 to 95°F) |
| Preferred operating temperature |
15 to 25°C (59 to 77°F) |
| Cooling |
Natural (passive) convection |
| BMS and Protection |
| Overcharge |
3.65 ± 0.01V per cell (58.4V) |
| Overcharge release |
3.45 ± 0.01V per cell (55.2V) |
| Over-discharge |
2.70 ± 0.05V per cell (43.2V) |
| Over-discharge release |
3.00 ± 0.05V per cell (48.0V) |
| Charge over-current |
110A, 5,000 ms delay; release 90A |
| Discharge over-current |
350A, 5,000 ms delay |
| Short circuit |
1,200A |
| Charge temperature protection |
Low 0°C (release 5°C); high 55°C (release 50°C) |
| Discharge temperature protection |
Low −20°C (release −17°C); high 55°C (release 50°C) |
| Internal fuse |
270A rated, UL 60691 (TEX150-R1N-XBZ) |
| Internal fuse transient overload |
1,200A for 3 s |
| Self-consumption |
20mA powered on; 200µA powered off |
| Communication and Monitoring |
| Bluetooth |
Bluetooth 4.0 through the included battery gauge |
| Battery gauge |
Mountable, Bluetooth meter S4855SW-H |
| App |
Epoch Li-Ion (iOS and Android) |
| Bluetooth range |
Typically about 10 m (33 ft) |
| CAN bus |
500 kbit/s |
| Victron GX port |
BMS-CAN or VE.Can |
| Victron GX devices |
Cerbo GX, Ekrano GX, Cerbo GX Mk2 |
| Firmware updates |
Over the air through the app |
| Controls |
Power button; mountable ON/OFF switch included |
| DIP switches |
8 (battery role and bank position) |
| Size and Weight |
| Dimensions (L x W x H) |
20.86 in x 8.65 in x 12.06 in (529.8 x 219.8 x 306.3 mm) |
| Height note |
Includes terminal posts |
| Case height (body) |
11.54 in (293.0 mm) |
| Terminal spacing |
17.99 in (457.0 mm), center to center |
| Weight |
97 lb (approx. 44 kg) |
| Terminals |
M8 threaded |
| Terminal torque |
8–12 N·m (71–106 lbf·in) |
| Mounting orientation |
Upright |
| Mounting points |
Six M8 nuts, 125 mm (4.92 in) spacing |
| Mounting bracket |
Epoch V2 & V2-T Mounting Hardware (8D battery bracket), sold separately |
| Case material |
ABS + PC blend, UL94 V-0 |
| Enclosure |
IP67, dust-tight |
| Water protection |
Temporary immersion to 1 m for 30 min |
| Not rated for |
Water jets, pressure washing or continuous submersion |
| Certifications |
| Battery pack |
UL 1973 |
| Cells |
UL 1642, UL 9540A, IEC 62619:2022 |
| Internal fuse |
UL 60691 (TEX150-R1N-XBZ) |
| Other |
CE, RoHS |
| Transport |
UN 3480, Class 9 |
| Warranty |
| Warranty |
11-year limited warranty |
| Years 1–5 |
Free repair or replacement |
| Years 6–11 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase; keep proof of purchase |
Epoch C48100A User Manual
Epoch C48100A Spec Sheet
Epoch C48100A Data Sheet