The Faraday Defense CYBER FX Low Frequency Barrier Shields Magnetic Fields up to 1000 Hz, Including 60 Hz Electrical Systems
The Faraday Defense CYBER FX Low Frequency Barrier is a nickel-free magnetic shielding film for AC or DC magnetic fields from 0 to 1000 Hz. It is 25.5 in wide and 1 mm thick, and it can be cut, bent and shaped to size. Faraday describes it as strong but thin and lightweight, suited to high field strength applications that need high saturation and good permeability.
It's for people who want to shield magnetic fields from electrical systems, appliances, speakers and magnets, or line walls, floors and vehicle firewalls. It is made for low frequency magnetic fields rather than radio frequency signals.
CYBER FX Low Frequency Barrier Features
Shields Magnetic Fields From 0 to 1000 Hz
Faraday Defense says the barrier works with AC or DC magnetic fields from 0 to 1000 Hz and shields electrical systems of 60 Hz. It has an initial permeability of 500, a relative permeability of 7000 and a saturation induction of 2.0 T.
Cut, Bend and Shape It to Size
Faraday notes that, unlike other films, CYBER FX can be cut, bent and shaped to size, so it can follow the surface you're covering. Cut it with sheet metal tools. Faraday recommends an oscillating tool with a metal cutting blade.
Several Ways to Attach It
The film is manageable and attaches with glue, screws or rivets, so you can fix it to walls, floors or the item you're covering.
Nickel-Free Construction
The film contains no nickel. It is laminated with a 0.005 in glass reinforced polypropylene tape, and Faraday lists a Curie temperature of 740°C (1364°F).
Real-World Applications
Appliances and speakers. Faraday lists covering magnets, speakers, vacuums and refrigerators among its uses.
Vehicles. Shape it to cover car floors and firewalls.
Walls and floors. Line walls and floors for wider coverage, including around 60 Hz electrical systems.
Practical Comparison
CYBER FX Versus an RF Shielding Fabric
A conductive RF shielding fabric is made for radio frequency signals. CYBER FX is a magnetic shielding film for AC or DC magnetic fields from 0 to 1000 Hz. Choose it when the source you want to shield is an electrical system, appliance, speaker or magnet.
CYBER FX Versus a Rigid Magnetic Shield
A rigid shield comes in a fixed shape. CYBER FX can be cut, bent and shaped to fit the surface you're covering, then fixed with glue, screws or rivets.
Buyer Guidance
Cutting and Installing
Edges are sharp, so handle the film and cut pieces with care. Use sheet metal tools or an oscillating tool with a metal cutting blade. The barrier tolerates 32°F to 140°F. Its polypropylene tape is UV sensitive, so cover the film if the installation is exposed to direct sunlight.
Planning Your Coverage
Each unit is 25.5 in wide by 1 ft long. Faraday lists the weight at 3.5 kg/m², or about 15 lb per 10 ft length, so choose fasteners that can hold the weight.
This May Be A Good Fit If
- You want to shield 60 Hz electrical systems
- You need a nickel-free magnetic barrier
- You want a film you can cut and bend to shape
Common Questions
What Fields Does CYBER FX Shield?
AC or DC magnetic fields from 0 to 1000 Hz, including 60 Hz electrical systems. Faraday doesn't give an RF dB rating for this barrier.
Can I Use It Outdoors?
The laminating tape is UV sensitive, so Faraday says to cover the film if it is exposed to direct sunlight. The barrier tolerates 32°F to 140°F.
Does It Contain Nickel?
No. Faraday describes the CYBER FX film as nickel-free.
What's Included
- 1 x CYBER FX Low Frequency Barrier, 25.5 in x 1 ft
Magnetic Shielding You Can Shape
The Faraday Defense CYBER FX Low Frequency Barrier gives you a nickel-free magnetic shielding film for fields up to 1000 Hz that you can cut, bend and fasten in place. If you'd like help planning how many feet you need for a wall, floor or appliance, the Outbound Power team is happy to help.
Faraday Defense CYBER FX Low Frequency Barrier for Magnetic Fields | 25.5 in x 1 ft Specifications
|
| Shielding |
| Field Type |
AC or DC magnetic fields |
| Frequency Range |
0 to 1000 Hz |
| Electrical Systems |
Shields 60 Hz electrical systems |
| Initial Permeability |
500 |
| Relative Permeability |
7000 |
| Saturation Induction |
2.0 T |
| Curie Temperature |
740°C (1364°F) |
| Material |
| Type |
Magnetic shielding film |
| Nickel |
Nickel-free |
| Laminate |
0.005 in glass reinforced polypropylene tape (UV sensitive) |
| Size |
| Width |
25.5 in |
| Length |
1 ft |
| Thickness |
1 mm |
| Weight |
3.5 kg/m² (about 15 lb per 10 ft length) |
| Handling |
| Cutting |
Sheet metal tools, oscillating tool with metal cutting blade recommended |
| Shaping |
Can be cut, bent and shaped to size |
| Attachment |
Glue, screws or rivets |
| Operating Temperature |
32°F to 140°F |
| Sunlight |
Cover if exposed to direct sunlight |
| Edges |
Sharp |