The Mango Power S Pro 10-in-1 Cable Connects Ten S Pro Microinverters on One AC Cable Run
The Mango Power S Pro 10-in-1 Cable is the AC cable for Mango's S Pro 240V/5000W microinverter system. It carries ten AC connectors on short branches off a single cable, one for each S Pro microinverter, and a long lead that an electrician wires into the AC junction box.
Mango states that this cable is required for proper operation of the S Pro microinverter and is sold separately. It is for homeowners and installers building an S Pro array, and Mango recommends having the system installed by a licensed local electrician.
Mango Power S Pro 10-in-1 Cable Features
Ten AC Connectors on One Cable
Each of the ten connectors sits on its own short branch, so ten microinverters share one cable run.
Made for the S Pro 240V System
Mango states that it is specifically compatible with the S Pro 240V/5000W system. Each S Pro microinverter has a nominal output of 500VA.
Routes Along the Mounting Rails
Mango has the AC cable routed along the rails with a connector lined up at each microinverter. Leave slack to avoid tension, secure the cable with clips or UV-resistant zip ties, and tuck excess cable beneath the panels.
Connectors Marked Do Not Disconnect Under Load
Each AC connector carries a printed STOP warning not to disconnect it under load. Mango calls for an AC disconnect tool when connectors need to come apart.
Real-World Applications
Rooftop Arrays. The cable runs along the mounting rail under the panels, with a connector at each microinverter position.
Roofs With Shade or Mixed Orientation. Mango says the S Pro suits roof installations with shading and multiple orientations because each microinverter tracks its own panel.
Practical Comparison
S Pro 10-in-1 Cable Versus Generic AC Wiring
A generic AC cable has no S Pro connectors on it. The 10-in-1 cable brings a matching connector to each of ten microinverter positions on one run, and Mango lists it as required for the S Pro.
Buyer Guidance
Branch Size and Installation
Mango lists a maximum of 7 S Pro microinverters per 20A branch on 12AWG cable and 11 per 30A branch on 10AWG cable, and a 30A branch needs a 30A breaker. Mango calls these recommended maximums; local regulations set the actual number. A licensed electrician should install the system and size the branch circuit, and local codes, permits and utility interconnection approval apply before the system connects to the grid.
This May Be A Good Fit If
- You are installing Mango Power S Pro microinverters
- You need ten microinverter connectors on one cable run
- Your licensed electrician is handling the 240V wiring
Common Questions
Is the 10-in-1 Cable Required for the S Pro?
Yes. Mango states that the S Pro 10-in-1 cable is required for proper operation of the S Pro microinverter and is sold separately.
Do I Need an Electrician to Install It?
Mango recommends a licensed local electrician. Mango says 240V hardwired grid-tie systems must comply with local utility policies and NEC standards and complete any required registration and inspection.
How Do I Protect Unused Connectors?
Mango has you seal unused cable ends with end caps and unused terminals with seal caps, so no exposed conductor is left open.
What's Included
- 1 x Mango Power S Pro 10-in-1 Cable
Ten Microinverters on One Cable Run
The Mango Power S Pro 10-in-1 Cable links up to ten S Pro microinverters on a single AC run for Mango's 240V system. Have a licensed electrician confirm the branch size, and the Outbound Power team is happy to help with questions about fit.
Mango Power S Pro 10-in-1 Cable for 240V S Pro Microinverters Specifications
|
| Cable |
| AC Connectors |
10 |
| Layout |
Short branch per connector off one cable |
| Lead End |
Bare cable end for AC junction box wiring |
| Connector Marking |
STOP warning, do not disconnect under load |
| Compatibility |
| System |
Mango Power S Pro 240V/5000W microinverter system |
| Microinverter |
Mango Power S Pro (500VA nominal output) |
| Max S Pro Units per 20A Branch (12AWG) |
7 (recommended) |
| Max S Pro Units per 30A Branch (10AWG) |
11 (recommended, 30A breaker) |
| Installation |
| Installer |
Licensed local electrician recommended |
| Grid Connection |
Local utility approval required before connecting |
| Unused Ends |
Seal with end caps and seal caps |
| Disconnecting |
AC disconnect tool |