The SunGold Power 48V 100AH Lithium Battery Self-Heating Server Rack Keeps 5.12kWh of Storage Ready to Charge in Low-Temperature Installations
The SunGold Power 48V 100AH Lithium Battery Self-Heating Server Rack is a 51.2V, 100Ah LiFePO4 battery (model SGH48100T) that stores 5.12kWh. It is a compact 3U pack with a built-in heater that uses charge current to warm the battery from temperatures as low as -13°F.
SunGold designed it for home energy storage and small commercial and industrial systems, including those in cold zones. It is UL1973 certified, talks to many inverter brands over RS485 or CAN, and can be paralleled up to 32 units as your storage needs grow.
SunGold Power 48V 100AH Lithium Battery Self-Heating Server Rack Features
Automatic Self-Heating Down to -13°F
The heater works between -13°F and 41°F (-25°C to 5°C) when the charge current is at least 0.08C, and it shuts off once the battery reaches 53.6°F (12°C). Between 14°F and 41°F, the heater runs while the battery charges at low current. Below 14°F, all charging current goes to the heater until the battery warms up. Heating does not count against the state of charge.
5.12kWh With Up to 96% Depth of Discharge
Each pack holds 5.12kWh, with 4.92kWh usable. It supports up to 96% depth of discharge in off-grid and backup systems, so more of the stored energy reaches your loads.
Expand to 32 Batteries
Up to 32 packs can be connected in parallel. Automatic dynamic addressing assigns each pack in the chain, and a built-in pre-charge circuit limits rush current when the bank connects to an inverter or charger.
RS485 and CAN Inverter Communication
The battery communicates over RS485 and CAN. SunGold lists compatibility with Growatt, Deye, Sol-Ark, SunGoldPower, Luxpower, EG4, Victron Energy, Schneider, SMA, Solis and more. DIP switches on the master battery select the inverter protocol.
Rapid Shutdown for North America
A rapid shutdown function is built in for the North American market, through the dry contact port. The dry contacts also provide charge enable and discharge enable signals.
7000+ Cycles and 10-Year Warranty
SunGold rates the battery for over 7000 deep cycles, a design life of up to 15 years and a 10-year warranty. The BMS protects against overcharge, over-discharge, over-current, short circuits and high or low temperature.
Installation Kit in the Box
The 3U pack measures 19.3 x 17.3 x 5.2 inches and has front handles. Rack mounting hardware, power cables, a grounding cable and a battery-to-battery communication cable are included, so it arrives ready for installation.
Real-World Applications
Cold-climate homes. Store solar energy for evenings and outages in places where the battery area gets cold in winter.
Off-grid cabins. Use the heater to keep accepting solar charge on cold mornings, then draw up to 96% of capacity at night.
Backup power systems. Pair with a compatible hybrid inverter to carry key loads through grid outages.
Small commercial and industrial storage. Stack packs in a rack and parallel up to 32 units as demand grows.
How It Compares to Common Alternatives
Versus a server rack battery without heating. A battery without heating relies on low-temperature protection, which blocks charging until the cells warm up. This model uses charge current to warm itself to 53.6°F, so a cold system can start charging sooner.
Versus a wall-mounted battery. A 3U rack battery installs in a rack or cabinet, so several packs share one footprint. A wall-mounted battery needs its own section of wall for each unit.
Versus a lead-acid bank. This battery adds a built-in BMS, closed-loop inverter communication and self-heating, with over 7000 rated cycles.
Is This Server Rack Battery the Right Fit
-
Inverter. Requires a 48V inverter or charger. Closed-loop communication needs a compatible RS485 or CAN protocol.
-
Location. Install indoors, out of direct sunlight, rain and snow. The maximum operating range is 14°F to 122°F, and 59°F to 86°F is optimal.
-
Weight. About 103lb per pack. SunGold calls for two people on site during installation.
-
Rack. A rack or cabinet that can carry the weight is needed and is not included.
-
Installer. Installation and commissioning should be done by a qualified person.
This may be a good fit if
- Your batteries sit in an unheated space
- You use a 48V hybrid or off-grid inverter
- You want UL1973 certified storage
- You may add many batteries later
Common Questions
How Does the Heater Work in Very Cold Weather?
Below 14°F, charging current goes only to the heater until the battery rises above 14°F. From there up to 41°F, the heater runs while the battery charges at low current. The heater turns off at 53.6°F and normal charging continues.
Why Does the Battery Stop at 98 to 99 Percent?
That is normal. The BMS charges slowly near full to protect cycle life, and it calibrates to 100% when it reaches cut-off. Floating the battery for about 0.5 to 1 hour calibrates the state of charge.
How Do I Wire Several Batteries to the Inverter?
Daisy-chain the communication cables from Link Out to Link In, and connect the master battery to the inverter. The positive and negative inverter cables must not both come from the same battery, or the packs will share current unevenly.
What Inverter Settings Does SunGold Suggest?
Absorption voltage 56.0V, float voltage 54.6V and low voltage cut-off 48.0V. For off-grid use, the low SOC cut-off is 4%.
What's Included
1 x Battery
- 1 x SGH48100T Battery Pack
- 1 x Manual
- 6 x M6 Float Nuts
- 4 x Combination Screws
- 2 x M8 Hexagon Bolts
- 2 x Short Power Cables (Red and Black)
- 2 x Power Cables (Red and Black)
- 1 x Grounding Cable
- 1 x Battery to Battery Communication Cable
2 x Batteries
- 2 x SGH48100T Battery Packs, each with the full kit listed above
4 x Batteries
- 4 x SGH48100T Battery Packs, each with the full kit listed above
Rack Storage Built for Cold Conditions
The SunGold Power 48V 100AH Lithium Battery Self-Heating Server Rack gives a 48V system 5.12kWh of UL1973 certified storage that warms itself before charging, with room to grow to 32 packs. At Outbound Power, we help customers size battery banks, racks and inverters for home and off-grid solar. If you have questions, our team is happy to help.
SunGold Power 48V 100AH Lithium Battery Specifications
|
| Electrical Characteristics |
| Battery Model |
SGH48100T |
| Chemistry |
Lithium iron phosphate battery |
| Nominal Voltage |
51.2V |
| Max. Voltage Range |
44.8~57.6V, shipping voltage >51.2V |
| Charge Voltage |
56.0V |
| Float Charge Voltage |
54.6V |
| Nominal Energy |
5.12kWh |
| Usable Energy |
4.92kWh |
| Nominal Capacity |
100Ah |
| Max. Depth of Discharge |
96% (off-grid and backup) |
| Standard Charge Current |
≤50A |
| Max. Charge Current |
70A |
| Standard Discharge Current |
≤50A |
| Max. Discharge Current |
100A (initial temp. ≤86°F (30°C)) |
| Peak Discharge Current |
101~119A @ 5 mins, 120~200A @ 15s |
| Cycle Life |
Over 7000 cycles |
| Design Life |
Up to 15 years |
| Communication and Expansion |
| Communication |
RS485 / CAN |
| Max. Parallel Number |
32 pcs |
| Dry Contact |
1 input, 2 outputs (charge and discharge enable), rapid shutdown function for US |
| Display |
RUN, ALM and SOC LED indicators |
| Temperature and Environment |
| Operation Temperature |
Charge 14°F to 122°F (-10 to 50°C), Discharge -4°F to 122°F (-20 to 50°C) |
| Optimum Operating Temperature |
59°F to 86°F (15°C to 30°C) |
| Heating Opening Condition |
-13°F (-25°C) ≤ T ≤ 41°F (5°C) @ I ≥ 0.08C |
| Heating Completion Condition |
T ≥ 53.6°F (12°C) |
| Storage Temperature (Off Mode) |
32°F (0°C) < T < 86°F (30°C) for under 6 months, 14°F (-10°C) < T < 113°F (45°C) for under 3 months |
| Recommended Storage Environment |
59°F to 95°F (15~35°C), 5~75%RH |
| Relative Humidity |
5%~90%, no condensation |
| Altitude |
<3000m |
| Installation |
Indoors, out of direct sunlight, rain and snow |
| Mechanical Characteristics |
| Format |
3U server rack |
| Dimensions |
19.3 x 17.3 x 5.2 inch (490 x 441 x 133mm) |
| Weight |
103lb (~47kg) |
| Certification and Warranty |
| Certification |
UL1973 |
| Warranty |
10 years |
SunGold Power SGH48100T Manual
SunGold Power SGH48100T UL 1973 Certificate