The Epoch Batteries 12V 100Ah (1.28kWh) LiFePO4 Battery Puts 1.28kWh of Deep-Cycle Power in a 21 lb Group 24 Case
The Epoch 12100-ECO is an Eco Series lithium iron phosphate battery rated at 12.8V nominal and 100Ah, for 1.28kWh (1,280Wh) of stored energy in a BCI Group 24 case. It delivers 100A continuous and 300A for up to 5 seconds, with a smart BMS, low-temperature charge protection and an IP54 enclosure. It has no Bluetooth and no internal heater.
It's made for 12V house power in RVs, vans and campers, marine house power and electronics, 12V trolling motors, small solar and off-grid systems, and backup power for 12V equipment. It is a deep-cycle battery, not cranking-rated, so it is not for engine starting.
Epoch Batteries 12V 100Ah (1.28kWh) LiFePO4 Battery Features
Group 24 Size at 21 lb
The case measures 10¼ x 6¾ x 9 in (260 x 171 x 229 mm) on a BCI Group 24 footprint and weighs 21 lb (9.5 kg). It fits standard Group 24 trays and boxes, but it isn't a drop-in replacement for every lead-acid installation, so check tray fit, lid and terminal clearance, cable size, overcurrent protection and charger profile first.
100A Continuous and 300A Peak Discharge
Epoch rates it for 100A maximum continuous discharge, about 1,280W of inverter DC input at 12.8V, so usable AC output is lower. The 300A rating covers start-up surges of up to 5 seconds only, such as a motor or inverter start-up. Any load that lasts longer must stay at or below 100A.
Low-Temperature Charge Protection
There is no internal heater. The BMS checks cell temperature before it allows charge current, blocks charging below 0°C (32°F) to protect the cells, and lets charging resume once the battery is back in its 0 to 55°C (32 to 131°F) charge range. It can still discharge down to -20°C (-4°F).
Smart BMS With 20+ Safety Features
The built-in BMS protects against overcharge, over-discharge, over-current, short circuit and high or low temperature, with a high-temperature reconnect at 50°C (122°F). Epoch lists UL 1642 and UL 9540A for the cells (not the complete battery), IEC 62619:2022 for the battery, and CE and RoHS marks. The BMS does not replace a DC-rated fuse or breaker near the positive terminal.
IP54 Dust-Protected, Splash-Resistant Case
Under IEC 60529, IP54 means dust-protected and protected against splashing water from any direction. It suits many everyday RV, marine and outdoor installs, but it is not waterproof or submersible. Don't submerge or pressure-wash it, or install it where standing water can collect, such as a bilge.
4,500+ Cycles With No Watering
Epoch rates it for 4,500+ cycles, with no watering, acid service or routine lead-acid maintenance. Routine inspections and terminal checks still apply. It's backed by a 6-year limited warranty with free replacement in Years 1–3, then 40% off MSRP on a replacement battery in Years 4–6.
Real-World Applications
RV, van and camper house power. Run lights, fans, controls, refrigerators and auxiliary 12V loads, with your converter, inverter charger and DC-to-DC charger all programmed for LiFePO4.
Marine house power. Power fish finders, sonar, GPS, chartplotters, radios, pumps and lighting. Keep the combined current of every connected device within the battery rating, and keep the battery out of bilge water.
12V trolling motors. Epoch says it may be used with a 12V trolling motor whose maximum current draw is at or below 100A continuous, with the wiring, fuse, controller and charger within the battery ratings. For a 24V or 36V motor, matched batteries in series give 24V (2S) or 36V (3S).
Small solar and backup systems. Epoch's planning estimates use 80% of nominal energy (about 1,024Wh) for DC loads at 25°C on a new, fully charged battery: about 20.5 hours at 50W, 10.2 hours at 100W, 4.1 hours at 250W and 2.0 hours at 500W.
Larger banks. Grow to 16 in parallel for 1,600Ah and 20.48kWh at 12V, or up to 4 in series for 24V, 36V or 48V-class systems.
How It Compares to Common Alternatives
Versus the Epoch Essential 105Ah. Both are Group 24 LiFePO4 batteries with IP54 enclosures. The Essential 105Ah stores 1.34kWh, delivers 105A continuous and adds Bluetooth, self-heating and an 11-year limited warranty, and Epoch rates it for 4,000+ cycles. The Eco 100Ah weighs 21 lb versus 22.1 lb and is rated for 4,500+ cycles.
Versus a Group 24 lead-acid battery. This battery needs no watering or acid service. It needs a LiFePO4 charge profile, lead-acid equalization, desulfation and repair modes must not be used, and it must never share a bank with lead-acid batteries.
Versus a cranking battery. This is a dedicated deep-cycle battery and is not built for the high current needed to start an engine. Use a cranking-rated battery for engine starting, since repeated engine starting on this model is excluded from warranty coverage.
Is This 12V Battery the Right Fit
-
Series and parallel. Up to 4 in series and 16 in parallel, using matched 12100-ECO batteries of the same age, condition and state of charge, each fully charged before it joins the bank. Never mix models, capacities, ages or chemistries.
-
Charger settings. A 12V LiFePO4 profile at 14.2–14.4V bulk/absorption, ending at C/20 (5A) or after 15 minutes, float off (preferred) or 13.3–13.6V, 13.2V re-bulk, with equalization and temperature compensation disabled. Charge at up to 50A, never more than 100A from all sources combined, and charge from an alternator through a DC-to-DC charger programmed for LiFePO4.
-
Cold charging. With no heater, charge only between 0°C and 55°C (32°F and 131°F). If it's too cold, move the battery somewhere warmer and let it stabilize. Never bypass the protection.
-
Fit and installation. Mount it upright and secured, not held by its cables. Torque the M8 female terminals to 8–12 Nm (71–106 in-lb), and install a DC-rated fuse or breaker as close as practical to the positive terminal.
-
Monitoring. There is no Bluetooth. Use a shunt-based battery monitor or system display, since voltage alone is not a precise state-of-charge reading on LiFePO4.
This may be a good fit if
- You're replacing a Group 24 house or trolling battery
- Your battery will charge above freezing
- Your loads stay at or below 100A continuous
- You don't need app monitoring
Common Questions
How Do I Track State of Charge Without Bluetooth?
Use a properly configured shunt-based battery monitor, which counts the amp-hours in and out. A full charge to the 14.6V SOC recalibration voltage is a good reference point for resetting the monitor to 100%.
What Charger Should I Use?
Any 12V charger, converter, inverter charger, solar controller or DC-to-DC charger that can be set to the LiFePO4 values above, such as the Epoch 12V 15A Lithium Battery Charger. A charger below the recommended 50A is suitable; it simply takes longer.
How Should I Store It?
Charge it to about 50% or higher, disconnect loads and chargers, and store it dry at 0 to 35°C (32 to 95°F). Check it at least every 3 months, since a battery left uncharged for more than 3 months is excluded from warranty coverage.
Do I Need to Register the Warranty?
Register within 90 days of purchase for full coverage. If you don't, the warranty period starts from the battery's manufacturing date. Coverage is for the original purchaser and needs proof of ownership.
What's Included
- 1 x Epoch 12V 100Ah Eco Series LiFePO4 Battery (12100-ECO)
Simple Lithium Power for Group 24 Systems
The Epoch Batteries 12V 100Ah (1.28kWh) LiFePO4 Battery gives a Group 24 tray 1.28kWh of LiFePO4 deep-cycle power at 21 lb, with smart BMS and low-temperature charge protection. If you have questions about charger settings, fit or building a bank, the Outbound Power team is happy to help.
Epoch 12100-ECO Specifications
|
| Electrical |
| Model |
12100-ECO |
| Series |
Eco Series |
| Battery type |
Deep-cycle (not cranking-rated) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell type |
Prismatic LiFePO4 |
| Cell configuration |
4S1P |
| Nominal voltage |
12.8V |
| Nominal capacity |
100Ah (at 0.2C) |
| Stored energy |
1,280Wh (1.28kWh) |
| Runtime planning energy |
About 1,024Wh (80% of nominal) |
| Operating voltage range |
10.0–14.6V |
| Maximum charge voltage |
14.6V |
| Cycle life |
4,500+ cycles |
| Charge and Discharge |
| Maximum continuous discharge |
100A |
| Peak discharge |
300A for up to 5 s (start-up surges only) |
| Inverter sizing |
DC input within 100A (about 1,280W at 12.8V) |
| Maximum continuous charge |
100A, all charging sources combined |
| Recommended charge current |
Up to 50A (0.5C) |
| Series connection |
Up to 4 (24V, 36V or 48V system class) |
| Parallel connection |
Up to 16 |
| Maximum 12V parallel bank |
1,600Ah / 20.48kWh |
| Maximum configuration |
4S16P (64 batteries) |
| 4S16P bank |
51.2V nominal, 1,600Ah, 81.92kWh |
| Recommended Charge Settings |
| Charger type |
12V LiFePO4 profile |
| Bulk / absorption voltage |
14.2–14.4V |
| Absorption end |
At C/20 (5A) or after 15 min, whichever comes first |
| Float voltage |
Disabled (preferred) or 13.3–13.6V |
| Re-bulk voltage |
13.2V |
| Equalization |
Disabled |
| Temperature compensation |
0 mV/°C (disabled) |
| Charge current, one battery |
Up to 50A recommended |
| Charge current, banks |
Up to 50% of bank capacity |
| BMS high-voltage cutoff |
14.6V |
| SOC recalibration |
14.6V |
| Alternator charging |
DC-to-DC charger programmed for LiFePO4 |
| Compatible charger |
Epoch 12V 15A Lithium Battery Charger |
| Temperature |
| Charge |
0 to 55°C (32 to 131°F) |
| Low-temperature charge protection |
Charging blocked below 0°C (32°F) |
| Self-heating |
No |
| Discharge |
−20 to 60°C (−4 to 140°F) |
| Storage (recommended) |
0 to 35°C (32 to 95°F) |
| High-temperature reconnect |
50°C (122°F) |
| BMS and Protection |
| Smart BMS |
Built in, 20+ safety features |
| Voltage and current protection |
Overcharge, over-discharge, over-current, short circuit |
| Temperature protection |
High- and low-temperature disconnects |
| External protection |
DC-rated fuse or breaker near the positive terminal |
| Communication and Monitoring |
| Bluetooth |
No |
| Monitoring |
External shunt-based battery monitor |
| Size and Weight |
| Dimensions (L x W x H) |
10.25 in x 6.75 in x 9 in (260 x 171 x 229 mm) |
| Footprint |
BCI Group 24 |
| Weight |
21 lb (9.5 kg) |
| Terminals |
M8 female |
| Terminal torque |
8–12 Nm (71–106 in-lb) |
| Mounting orientation |
Upright |
| Case material |
ABS and PC blend, UL94-V0 |
| Enclosure |
IP54 (IEC 60529) |
| Water and dust |
Dust-protected, splash-resistant |
| Not rated for |
Submersion, pressure washing or standing water |
| Matching tray |
Epoch tray for 12105A-H and 12100-ECO, sold separately |
| Certifications |
| Cells |
UL 1642, UL 9540A (cells only) |
| Battery |
IEC 62619:2022 |
| Compliance marks |
CE, RoHS |
| Transport |
UN 38.3, Class 9 |
| Warranty |
| Warranty |
6-year limited warranty |
| Years 1–3 |
Free replacement |
| Years 4–6 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase for full coverage |
Epoch 12100-ECO User Manual
Epoch 12100-ECO Spec Sheet
Epoch 12100-ECO Data Sheet