The Epoch Batteries 24V 230Ah (5.89kWh) LiFePO4 Battery Gives a 24V System Victron CAN, Self-Heating and Bluetooth in One IP67 Case
The Epoch C24230A is a V2 Elite Series lithium iron phosphate battery rated at 25.6V nominal and 230Ah, for 5,888Wh (5.89kWh) of stored energy in one managed case with one BMS. A single case means fewer interconnects and cleaner routing than a 24V bank of smaller batteries.
It's made for 24V house-power and energy-storage systems in RVs, motorhomes, boats, off-grid cabins, solar banks and home backup, and for 24V trolling motors. It is a deep-cycle battery, not a cranking battery for engine starting.
Epoch Batteries 24V 230Ah (5.89kWh) LiFePO4 Battery Features
Native Victron CAN Communication
The battery connects to a compatible Victron GX device (Cerbo GX, Ekrano GX or Cerbo GX Mk2) over CAN bus at 500 kbit/s, using the included communication harness. With DVCC on and Epoch set as the controlling BMS and battery monitor, it reports its status and sets the charge voltage and current limits of your Victron chargers.
Self-Heating for Charging in the Cold
LiFePO4 cells must not be charged below 0°C (32°F). When a charge source is connected and the cells are too cold, the BMS holds off charging while the internal heater, powered by the charge source, warms them. Charging resumes when the cells reach 5°C (41°F), and with self-heating, charging is supported from -30°C (-22°F) ambient.
IP67 Dust-Tight, Immersion-Rated Enclosure
The enclosure is dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes. It is not rated for water jets, pressure washing or continuous submersion, so install it where it stays dry in normal use, with all harness connectors fully seated.
110A Continuous Charge and Discharge
Epoch rates it for 110A maximum continuous discharge and 110A maximum continuous charge, about 2,816W DC at 25.6V before inverter losses. It handles a 300A peak discharge and 200A charge for short durations, and the BMS disconnects at 280A discharge or 200A charge after 5 seconds. If your inverter's continuous DC input can exceed 110A, add batteries in parallel.
Bluetooth Monitoring Through the Included Gauge
The included mountable battery gauge shows state of charge and links over Bluetooth to the Epoch Li-Ion app (iOS and Android), where the battery appears as C24230A_ followed by its serial number. The app shows voltage, current, power, cell voltages, cell balance, temperatures, history and battery events, and installs firmware updates over the air.
Smart BMS and 270A Internal Fuse
The BMS protects against over- and under-voltage, over-current, short circuit and high or low temperature, backed by a 270A internal fuse (UL 60691). Epoch lists UL 1973 for the pack and UL 1642, UL 9540A and IEC 62619:2022 for the cells. The internal fuse protects the battery, not your cables, so you still need a DC-rated fuse or breaker close to the battery positive.
3,500+ Cycles and an 11-Year Limited Warranty
Epoch rates it for 3,500+ cycles to 70% remaining capacity, with no watering or equalizing. It's backed by an 11-year limited warranty with free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11.
Real-World Applications
24V RV and motorhome house power. Run a motorhome, fifth wheel, travel trailer or camper van from one battery, mounted upright and secured against vibration and braking.
Marine house banks and 24V trolling motors. Power electronics and house loads on yachts and cruising boats, or a 24V trolling motor where voltage, current and runtime needs match.
Off-grid solar and cabins. Start with one 5.89kWh battery and grow to as many as 16 in parallel for 3,680Ah and 94.21kWh at 25.6V.
48V-class strings. Wire 2 in series for 51.2V nominal, with every charger, inverter, fuse, switch and conductor rated for the 58.4V the string reaches at full charge.
Home backup. Epoch's planning estimates use 80% of nominal energy (about 4,710Wh) for a constant DC load, before inverter losses: about 9.4 hours at 500W, 4.7 hours at 1,000W and 1.7 hours at 2,816W.
How It Compares to Common Alternatives
Versus a bank of smaller 24V batteries. This battery puts 5.89kWh behind one BMS, with fewer interconnects, fewer connection points and cleaner routing than a bank of small batteries.
Versus the V2-T version (C24230A-A). Epoch's 24V 230Ah V2-T Elite is a different version with its own manual. Check the model number on the label before you follow any procedure.
Versus a Group 8D lead-acid battery. If you're replacing an 8D, confirm tray fit, hold-down and lid clearance first. This battery needs no watering, and lead-acid equalization, desulfation or repair modes must not be used on it.
Is This 24V Battery the Right Fit
-
Bank limits. Up to 16 in parallel or 2 in series, using matched C24230A batteries of the same age, capacity and state of charge, with the DIP switches set for the bank. Series-parallel arrays are not covered by Epoch's published DIP switch settings.
-
Charger settings. Lithium (LiFePO4) CC/CV, 28.4V absorption for at least 15 minutes per battery in the bank, 27.0V float, 26.6V re-bulk, equalization and temperature compensation disabled. Keep every source, and the total of all sources, within 110A continuous. Never charge above 29.2V, and program every charge source, Victron included, in case CAN communication is lost.
-
Cold charging. Below freezing, the heater must warm the cells before charge current flows, so expect a delay before the state of charge starts to rise.
-
Fit and weight. 20.86 x 8.65 x 12.06 in (529.8 x 219.8 x 306.3 mm) including terminal posts, and 97 lb (approx. 44 kg). Lift with two people or a lifting aid and install it upright. The Epoch V2 & V2-T Mounting Hardware (8D battery bracket) fastens to threaded inserts on the case and is sold separately.
-
Installation. Epoch calls for qualified installers. Torque the M8 terminals to 8–12 N·m, and charge the battery fully before first use.
This may be a good fit if
- You're building or upgrading a 24V house bank
- You use a Victron Cerbo GX, Ekrano GX or Cerbo GX Mk2
- You run a 24V trolling motor or marine house loads
- You need to charge in freezing weather
Common Questions
What Size Inverter Can One Battery Support?
At 25.6V, 110A continuous is about 2,816W DC before inverter losses. Epoch estimates DC input current as AC load divided by (battery voltage x inverter efficiency), so a 2,000W load through a 90%-efficient inverter draws about 87A. If the inverter's continuous DC input can exceed 110A, add batteries in parallel.
How Cold Can It Discharge?
Discharge is rated from -20°C to 55°C (-4°F to 131°F), with no heating needed.
What Happens if CAN Communication Is Lost?
The BMS still protects the battery on its own, and Bluetooth monitoring works with or without a GX device. Your chargers fall back to their programmed settings, which is why each one should be set to Epoch's values.
How Should I Store It?
Charge it to at least 50%, switch it off and disconnect loads and chargers. Store it at 0 to 35°C (32 to 95°F) for up to a year, and check the state of charge at least every 3 months, since the warranty does not cover a battery left uncharged for more than 3 months.
What's Included
- 1 x Epoch 24V 230Ah V2 Elite LiFePO4 Battery (C24230A)
- 1 x Communication Harness
- 1 x Mountable Battery Gauge (Bluetooth State-of-Charge Meter)
- 1 x Mountable ON/OFF Switch
Heated 24V Storage Built for Victron and Off-Grid Systems
The Epoch Batteries 24V 230Ah (5.89kWh) LiFePO4 Battery gives a 24V system 5.89kWh in one IP67 case, with Victron CAN communication, self-heating and Bluetooth monitoring. If you have questions about charger settings, Victron setup or sizing a bank, the Outbound Power team is happy to help.
Epoch C24230A Specifications
|
| Electrical |
| Model |
C24230A |
| Series |
V2 Elite Series |
| Battery type |
Deep-cycle (not for engine starting) |
| Chemistry |
LiFePO4 (lithium iron phosphate) |
| Cell type |
Prismatic LiFePO4 |
| Cell configuration |
8S1P (230Ah cells) |
| Nominal voltage |
25.6V (3.2V per cell) |
| Nominal capacity |
230Ah |
| Stored energy |
5,888Wh (5.89kWh) |
| Operating voltage range |
20.0–29.2V |
| Maximum charge voltage |
29.2V (3.65V per cell) |
| Minimum voltage |
20.0V (2.5V per cell) |
| Self-discharge |
≤3% per month |
| Cycle life |
3,500+ cycles to 70% remaining capacity |
| Charge and Discharge |
| Maximum continuous discharge |
110A |
| Peak discharge |
300A (short duration) |
| Continuous power at 25.6V |
2,816W DC (before inverter losses) |
| Maximum continuous charge |
110A per battery, all sources combined |
| Maximum charge, short duration |
200A |
| BMS discharge over-current trip |
280A after 5 s |
| BMS charge over-current trip |
200A after 5 s |
| Series connection |
Up to 2 batteries (51.2V nominal) |
| Full-charge voltage, 2 in series |
58.4V |
| Parallel connection |
Up to 16 batteries |
| Maximum parallel bank |
3,680Ah / 94.21kWh at 25.6V nominal |
| Series-parallel |
Not covered by Epoch's published DIP switch settings |
| Recommended Charge Settings |
| Charger type |
Lithium (LiFePO4) compatible, CC/CV |
| Bulk / absorption voltage |
28.4V |
| Absorption time |
At least 15 min per battery in the bank |
| Float voltage |
27.0V |
| Re-bulk voltage |
26.6V |
| Equalization |
Disabled |
| Temperature compensation |
Disabled (0 mV/°C) |
| Charge current |
110A max. continuous per battery |
| BMS high-voltage cutoff |
29.2V |
| Victron GX (DVCC) |
DVCC on; controlling BMS and battery monitor set to Epoch |
| Alternators |
DC-DC charger, or alternator regulator set up for lithium |
| Temperature |
| Charge (cell temperature) |
0 to 55°C (32 to 131°F) |
| Charge with self-heating (ambient) |
−30 to 55°C (−22 to 131°F) |
| Charging resumes after heating |
Cells at 5°C (41°F) |
| Self-heating power |
From the charge source |
| Discharge |
−20 to 55°C (−4 to 131°F) |
| Storage, up to 1 month |
−20 to 45°C (−4 to 113°F) |
| Storage, up to 1 year |
0 to 35°C (32 to 95°F) |
| Preferred operating temperature |
15 to 25°C (59 to 77°F) |
| BMS and Protection |
| Overcharge |
3.65 ± 0.01V per cell (29.2V) |
| Overcharge release |
3.45 ± 0.01V per cell (27.6V) |
| Over-discharge |
2.70 ± 0.05V per cell (21.6V) |
| Over-discharge release |
3.00 ± 0.05V per cell (24.0V) |
| Charge over-current |
200A, 5,000 ms delay; release 125A |
| Discharge over-current |
280A, 5,000 ms delay |
| Short circuit |
1,200A |
| Charge temperature protection |
Low 0°C (release 5°C); high 55°C (release 50°C) |
| Discharge temperature protection |
Low −20°C (release −17°C); high 55°C (release 50°C) |
| Internal fuse |
270A rated, UL 60691 (TEX150-R1N-XBZ) |
| Internal fuse transient overload |
1,200A for 3 s |
| Self-consumption |
20mA powered on; 200µA powered off |
| Communication and Monitoring |
| Bluetooth |
Through the included battery gauge |
| Battery gauge |
Mountable, with Bluetooth |
| App |
Epoch Li-Ion (iOS and Android) |
| Battery name in the app |
C24230A_ followed by the serial number |
| Bluetooth range |
Typically about 10 m (33 ft) |
| CAN bus |
500 kbit/s |
| Victron GX port |
BMS-CAN or VE.Can |
| Victron GX devices |
Cerbo GX, Ekrano GX, Cerbo GX Mk2 |
| Firmware updates |
Over the air through the app |
| Controls |
Power button; mountable ON/OFF switch included |
| DIP switches |
8 (battery role and bank position) |
| Size and Weight |
| Dimensions (L x W x H) |
20.86 in x 8.65 in x 12.06 in (529.8 x 219.8 x 306.3 mm) |
| Height note |
Includes terminal posts |
| Weight |
97 lb (approx. 44 kg) |
| Terminals |
M8 threaded |
| Terminal torque |
8–12 N·m (71–106 lbf·in) |
| Mounting orientation |
Upright |
| Mounting points |
Threaded inserts for the optional bracket |
| Mounting bracket |
Epoch V2 & V2-T Mounting Hardware (8D battery bracket), sold separately |
| Case material |
ABS + PC blend, UL94 V-0 |
| Enclosure |
IP67, dust-tight |
| Water protection |
Temporary immersion to 1 m for 30 min |
| Not rated for |
Water jets, pressure washing or continuous submersion |
| Certifications |
| Battery pack |
UL 1973 |
| Cells |
UL 1642, UL 9540A, IEC 62619:2022 |
| Internal fuse |
UL 60691 (TEX150-R1N-XBZ) |
| Other |
CE, RoHS |
| Transport |
UN 3480, Class 9 |
| Warranty |
| Warranty |
11-year limited warranty |
| Years 1–5 |
Free repair or replacement |
| Years 6–11 |
40% off MSRP on a replacement battery |
| Registration |
Within 90 days of purchase; keep proof of purchase |
Epoch C24230A User Manual
Epoch C24230A Spec Sheet
Epoch C24230A Data Sheet