The Faraday Defense T.R.A.P.-AC EMP Protection Plug Puts a 5,000-Watt Transient Suppressor Right in Your Generator's AC Outlet
The Faraday Defense T.R.A.P.-AC is a high-voltage 5,000-watt transient voltage suppression device built into a plug. It goes into the three-prong AC receptacle of an inverter or portable generator, with no wiring and no tools.
Faraday designed the T.R.A.P. line to guard against very fast transients from any source, including radiated energy from a nearby lightning strike or an overhead electromagnetic pulse (EMP). The T.R.A.P.-AC is made for owners of portable generators and inverters who want transient protection on the equipment they count on during an outage.
Faraday Defense T.R.A.P.-AC EMP Protection Plug Features
5,000-Watt Transient Voltage Suppression
Inside the plug is a high-voltage 5,000-watt transient voltage suppression device. Plugged into an AC receptacle, it works to suppress fast voltage transients at that outlet.
Plugs Into a Standard Three-Prong Receptacle
The T.R.A.P.-AC fits the three-prong AC receptacle of an inverter or portable generator. The plug face is marked NEMA 5-15 and 15A 125V. Push it in and it's installed.
Enclosed Back With No Pass-Through
The back of the T.R.A.P.-AC is enclosed. It doesn't pass power through, so its only job is suppressing transients at the outlet it occupies.
Small Device for Short Pulses
Faraday explains that the danger to inverters and portable generators from an EMP is the high voltage introduced on the cables by E1 and E2. Those transient voltages last only nanoseconds to microseconds, so a small device can suppress them.
Real-World Applications
Backup generators. Keep a T.R.A.P.-AC in an open outlet on the portable generator you rely on during outages.
Inverters. Plug it into the three-prong AC receptacle of an inverter to add transient protection to that equipment.
Layered generator protection. Faraday describes two ways to protect inverters and portable generators. The T.R.A.P.-AC covers the transient protection side, and an EMP bag or EMP cloth covers the enclosure side.
Practical Comparison
T.R.A.P.-AC Versus an EMP Bag
An EMP bag or EMP cloth encloses the generator or inverter in something conductive, which is one of the two ways Faraday describes. The T.R.A.P.-AC is the other way Faraday lists, a transient protection device inserted into the AC outlet. Faraday lists both as fundamental ways to protect this equipment.
T.R.A.P.-AC Versus a Plug-In Surge Strip
A surge strip passes power through to the devices plugged into it. The T.R.A.P.-AC has an enclosed back and passes no power, so it occupies one receptacle and is dedicated to transient suppression there.
Buyer Guidance
Choosing an Outlet
Look for a three-prong AC receptacle on your generator or inverter that the plug fits. Because the T.R.A.P.-AC doesn't pass power through, choose an outlet you can leave occupied.
Adding More Than One T.R.A.P.
Faraday says putting energy traps at multiple points in a generator or inverter helps to better shunt away unwanted energy. T.R.A.P.s can go in both the 12-volt DC auxiliary and the 120-volt AC outlets, so consider one for each type your equipment has.
This May Be A Good Fit If
- You own a portable generator or inverter
- Your equipment has a three-prong AC receptacle
- You want transient protection with no wiring
- You plan to pair it with an EMP bag or EMP cloth
Common Questions
What Does the T.R.A.P.-AC Protect Against?
Faraday designed the T.R.A.P. to guard against very fast transients from any source. That includes radiated energy from a nearby lightning strike or an overhead EMP.
How Can Something This Small Help Against an EMP?
The danger to inverters and portable generators is the high voltage introduced on their cables by E1 and E2. Those transients are extremely brief, so small devices can suppress them. Faraday notes a home is different, because it would also see a powerful E1 current surge from the power grid.
Can I Use More Than One on a Generator or Inverter?
Yes. Faraday says energy traps at multiple points help to better shunt away the unwanted energy.
Does the T.R.A.P.-AC Have an Outlet on the Back?
No. The back is enclosed, and it does not pass power through.
What's Included
- 1 x Faraday Defense T.R.A.P.-AC Transient Suppression Plug
Plug-In Transient Protection for Generators and Inverters
The Faraday Defense T.R.A.P.-AC EMP Protection Plug puts a 5,000-watt transient voltage suppression device into the three-prong AC receptacle of your portable generator or inverter. If you'd like help planning transient protection for your generator setup, the Outbound Power team is happy to help.
Faraday Defense T.R.A.P.-AC EMP Protection Plug for Generators and Inverters Specifications
|
| Fit |
| Equipment |
Inverters and portable generators |
| Outlet |
Three-prong AC receptacle |
| Outlet Types for T.R.A.P.s |
12-volt DC auxiliary and 120-volt AC outlets |
| Plug Face Marking |
NEMA 5-15, 15A 125V |
| Electrical |
| Suppression Rating |
5,000 W, high-voltage transient voltage suppression |
| Pass-Through Outlet |
No, back is enclosed |
| Protection |
| Transient Sources |
Very fast transients from any source, including nearby lightning and overhead EMP |
| EMP Threat Addressed |
E1 and E2 transient voltages on equipment cables |
| Installation |
| Method |
Plugs into the AC receptacle |
| Wiring Required |
No |
| Multiple Units |
Yes, traps at multiple points help shunt unwanted energy |