The Go Power! Class T Inverter Fuse With Block Protects Your Inverter's Battery Cable With One Block for 110 to 400 Amp Fuses
The Go Power! Class T Inverter Fuse With Block is a complete fuse kit for the positive cable between your battery bank and your inverter. You get a DC-rated fuse block base, a clear protective cover, mounting hardware and one Class T fuse in 110, 200, 300 or 400 amps.
It works on 12, 24, 32 and 48 volt battery systems and accepts #6 to 4/0 AWG cable on 5/16 inch studs. Battery cables are sold separately.
Go Power! Class T Inverter Fuse With Block Features
One Block for Every Fuse Rating
One block size fits all four fuses. If you move up to a larger inverter later, you change the fuse instead of the block, as long as your cable suits the new rating.
Class T Fuse With a 50,000 Amp Interrupt Rating
The DC-rated Class T fuse has slow-blow functionality and a 50,000 amp interrupt rating. Filler inside the fuse suppresses arcing, and its current-limiting design interrupts a short circuit very quickly.
Clear Cover Over the Live Terminals
The transparent cover snaps onto the base, keeps tools and stray leads off the terminals and lets you see the fuse. It is impact resistant, heat resistant and self-extinguishing.
Fire-Rated Base and Stainless Studs
The insulated base is fiberglass-reinforced polycarbonate with a V-0 fire rating, and the 5/16 inch fastenings are 18-8 stainless steel.
Real-World Applications
Lithium and large AGM banks. Go Power says these banks can deliver thousands of amps into a short circuit. A Class T fuse is designed to clear that fault without arcing or rupturing.
Inverter upgrades. Start with the fuse your inverter needs today, then fit a larger Go Power! fuse in the same block when you upgrade.
Practical Comparison
Class T Fuse Block Versus ANL or MIDI Fuses
Go Power says ANL and MIDI fuses are not rated to safely clear the fault current a lithium or large AGM bank can deliver. A Class T fuse interrupts that fault without arcing or rupturing.
Buyer Guidance
Choosing the Fuse Rating
Size the fuse to your inverter and cable, and follow your inverter manual. The spec table lists Go Power's fuse ratings for 1000 to 4000 watt inverters at 12, 24 and 48 volts, such as 110 amps for a 1000 watt inverter at 12 volts.
Where and How to Mount It
Mount the block in the positive cable close to the battery, on a firm surface in a dry, easy-to-reach spot where the danger label stays visible. Keep it out of engine compartments, where it may exceed its maximum operating temperature. Fasten it through the two holes in the base and torque the cable lugs to 10 ft-lbs.
This May Be A Good Fit If
- You're installing an inverter on a 12 to 48 volt bank
- You want Class T protection for a lithium or AGM bank
- Your battery cable is #6 to 4/0 AWG
- You may move to a larger inverter later
Common Questions
Where Does the Fuse Block Go?
In the positive cable between the battery bank and the inverter, as close to the battery positive terminal as practical.
Which Replacement Fuse Do I Buy Later?
The Go Power! F-110, F-200, F-300 or F-400, or any standard Class T fuse of the same rating.
What Should I Do if the Fuse Blows?
The label on the cover says to disconnect all power sources, turn off all loads and check for the cause of the fault before you replace the fuse.
What's Included
- 1 x DC-Rated Fuse Block Base
- 1 x Transparent Protective Cover
- 1 x Mounting Hardware Set
- 1 x Class T Fuse, 110, 200, 300 or 400 Amp (Option Chosen)
Class T Protection That Grows With Your System
The Go Power! Class T Inverter Fuse With Block gives your inverter's battery cable DC-rated Class T protection, a clear cover over the terminals and room to move up to a 400 amp fuse. If you'd like help choosing the fuse rating for your inverter, the Outbound Power team is happy to help.
Go Power! Class T Inverter Fuse With Block Specifications
|
| Model |
FBL-110, FBL-200, FBL-300, FBL-400 |
| Options |
| FBL-110 |
Block with 110 A Class T fuse |
| FBL-200 |
Block with 200 A Class T fuse |
| FBL-300 |
Block with 300 A Class T fuse |
| FBL-400 |
Block with 400 A Class T fuse |
| Electrical |
| Fuse Type |
Class T, DC rated, slow blow |
| Fuse Ratings |
110 A, 200 A, 300 A, 400 A |
| Battery Systems |
12, 24, 32 or 48 V DC |
| Interrupt Rating |
50,000 A |
| Fuse Block DC Rating |
300 V, 400 A |
| Withstand Rating |
50,000 A RMS symmetrical |
| Fuse DC Rating |
160 VDC |
| Replacement Fuses |
F-110, F-200, F-300, F-400 |
| Cable and Mounting |
| Cable Range |
#6 to 4/0 AWG |
| Studs |
5/16 in, 18-8 stainless steel |
| Terminal Lugs |
Optional universal terminal lugs |
| Lug Torque |
10 ft-lbs |
| Mounting |
2 holes in the base |
| Physical |
| Base |
Insulated fiberglass-reinforced polycarbonate, V-0 fire rated |
| Cover |
Transparent; impact resistant, heat resistant, self-extinguishing |
| Dimensions |
163 x 43 x 79 mm / 6.4 x 1.7 x 3.1 in |
| Net Weight |
0.4 kg / 0.9 lb |
| Fuse Size by Inverter Size |
| 1000 W Inverter |
12 V 110 A; 24 V 110 A |
| 1500 W Inverter |
12 V 200 A; 24 V 110 A; 48 V 110 A |
| 2000 W Inverter |
12 V 300 A; 24 V 200 A; 48 V 110 A |
| 2500 W Inverter |
12 V 300 A; 24 V 200 A; 48 V 110 A |
| 3000 W Inverter |
12 V 400 A; 24 V 200 A; 48 V 200 A |
| 4000 W Inverter |
24 V 300 A; 48 V 200 A |
Go Power! Class T Inverter Fuse With Block Manuals and Documents
Go Power! FBL Fuse Block Manual
Go Power! FBL Fuse Block and GP-DC Kit Spec Sheet