The Renogy 20A/30A/40A/60A/80A/100A/200A/300A/400A ANL Fuse Set with Fuse Gives Your DC Circuit a Covered, Replaceable Fuse
The Renogy 20A/30A/40A/60A/80A/100A/200A/300A/400A ANL Fuse Set with Fuse pairs an ANL fuse with a clear, non-conductive cover and a base with two 5/16 inch (M8) studs. It is made for DC systems operating below 72V. Choose the current rating that matches your circuit.
It is for anyone fusing a charge controller, battery, inverter or the wires that connect them in a solar or battery system.
Renogy 20A/30A/40A/60A/80A/100A/200A/300A/400A ANL Fuse Set with Fuse Features
Protects Your Controller, Battery and Wires
Renogy says the set protects your charge controller, battery, inverter and connecting wires from overcurrent. The ANL fuse is made of high-quality alloy and brass copper.
Clear Cover for Custom Installation
The clear protective cover is non-conductive, and Renogy describes it as ideal for custom installation. The same cover is compatible with all of the fuse ratings.
Ignition Protection for Closed Spaces
Renogy says ignition protection guarantees safe use of the fuse in RVs, boats or any other closed environments. The fuse is also RoHS compliant.
Fuse Replaces Without the Holder
When a fuse blows, you can replace the fuse alone. Replace the whole set only if the holder or terminals are damaged.
Real-World Applications
Controller to battery wiring. Renogy's wiring diagram places the ANL fuse in the positive cable between a charge controller and a battery.
Inverter circuits. Use the fuse set on the cable feeding an inverter.
RVs and boats. The ignition protection suits closed environments like these.
Practical Comparison
Fuse Set Versus a Bare Fuse
A bare ANL fuse needs a holder. This set includes the base and the clear cover, so the studs and fuse are covered once it is installed.
Lower Ratings Versus Higher Ratings
All nine ratings share a voltage rating below 72V. Higher ratings carry more current and have a higher interrupt capacity, so match the rating to your circuit.
Buyer Guidance
Choosing the Fuse Size
Follow the fuse size in the manual for your charge controller, battery charger or inverter. Renogy's page also suggests a fuse rated at 1.25 times the maximum operating current, for example an 80A fuse for a 60A MPPT controller. Use a rating that matches your system's rated current and never install a mismatched fuse.
Installation Notes
Disconnect all power before installing or replacing a fuse, and wear insulating gloves. Use ring terminals sized for M8 studs and tighten the nuts to 70.8 inch pounds (8 N·m). Fuse cables are not included.
This May Be A Good Fit If
- Your DC system runs below 72V
- You want a covered fuse holder in one set
- You have ring-terminal cables for 5/16 inch studs
- You want to replace a blown fuse without replacing the holder
Common Questions
What size are the posts?
The posts are 5/16 inch studs (M8). Renogy recommends ring lugs sized for M8 to M10.
Does the set include a fuse cable?
No. You need to buy a fuse cable separately.
Can I replace just the fuse?
Yes. Renogy says the fuse can be removed and replaced on its own.
What's Included
- 1 x ANL Fuse
- 1 x ANL Fuse Cover
- 1 x ANL Fuse Base with Studs, Nuts and Washers
Each option includes one set with the fuse rating you choose.
A Covered, Replaceable Fuse for Your DC Wiring
The Renogy 20A/30A/40A/60A/80A/100A/200A/300A/400A ANL Fuse Set with Fuse protects your DC circuit and keeps the connections covered. If you need help choosing a rating, the Outbound Power team is happy to help.
Renogy 20A/30A/40A/60A/80A/100A/200A/300A/400A ANL Fuse Set with Fuse Specifications
|
| Electrical |
| Voltage Rating |
72V or below |
| 20A Interrupt Capacity |
40A |
| 30A Interrupt Capacity |
60A |
| 40A Interrupt Capacity |
80A |
| 60A Interrupt Capacity |
120A |
| 80A Interrupt Capacity |
160A |
| 100A Interrupt Capacity |
200A |
| 200A Interrupt Capacity |
400A |
| 300A Interrupt Capacity |
600A |
| 400A Interrupt Capacity |
800A |
| Current Ratings |
20A, 30A, 40A, 60A, 80A, 100A, 200A, 300A, 400A (by option) |
| Blow Time at 220% of Rating |
60 seconds at maximum |
| Blow Time at 250% of Rating |
0.8 s to 10 s |
| Blow Time at 400% of Rating |
0.2 s to 2 s |
| Materials |
| Fuse Material |
Alloy and brass copper |
| Cover |
Clear, non-conductive |
| Compliance |
RoHS |
| Installation |
| Post Size |
5/16 in studs (M8) |
| Ring Terminal Size |
M8 studs (M8 to M10 acceptable) |
| Recommended Nut Tightening Torque |
70.8 in lbs (8 N·m) |
| Size and Weight |
| Dimensions |
4.88 x 1.48 x 1.48 in (124 x 37.6 x 37.5 mm) |
| Warranty |
| Material and Workmanship Warranty |
1 year |
Renogy 20A/30A/40A/60A/80A/100A/200A/300A/400A ANL Fuse Set with Fuse Manual