The Victron SmartSolar MPPT 150/35 Solar Charge Controller Handles Higher Voltage Solar Strings and 12, 24 or 48 V Batteries With Bluetooth Setup
The Victron SmartSolar MPPT 150/35 is a solar charge controller that takes solar strings up to 150 V open-circuit and charges 12 V, 24 V or 48 V battery banks at up to 35 A. Victron lists nominal solar input of 500 W at 12 V, 1,000 W at 24 V and 2,000 W at 48 V.
It has Bluetooth built in for setup and monitoring with the VictronConnect app, and a VE.Direct port for a GX device. This part number, SCC115035210, uses screw terminals for solar and battery wires. It is a good fit for RV, marine and off-grid systems where longer series strings, a 48 V bank or a future move to a higher system voltage matter.
Victron SmartSolar MPPT 150/35 Solar Charge Controller Features
12 V, 24 V And 48 V Battery Support
The controller auto-selects 12 V, 24 V or 48 V battery voltage. Victron's datasheet says a software tool is needed to select 36 V. That flexibility means the same controller can follow you if you upgrade your battery bank later.
150 V Solar Input With A Practical Start-Up Limit
Victron lists 150 V as the absolute maximum open-circuit solar voltage in the coldest conditions, and 145 V as the start-up and operating maximum. Size your series strings below that, using the panel's cold-weather Voc, not the number on the sticker.
35 A Charge Current And Clear Power Ratings
Nominal solar power is 500 W at 12 V, 1,000 W at 24 V, 1,500 W at 36 V and 2,000 W at 48 V. If you connect more solar, the controller limits input power. Full output current is available up to 40 degrees C (104 degrees F).
Ultrafast MPPT Tracking
Victron says ultra-fast tracking can raise harvest by up to 30 percent compared with PWM controllers and up to 10 percent compared with slower MPPT controllers. It also handles partial shading by locking onto the optimum power point.
Bluetooth And VE.Direct
Use your phone to set up, monitor, view history and update the charger. Connect the VE.Direct port to a Cerbo GX or other GX device for VRM remote monitoring.
Adaptive Charging With Adjustable Settings
The controller uses a multi-stage adaptive algorithm with eight preset algorithms and a fully programmable option. Default absorption is 14.4 / 28.8 / 57.6 V and float is 13.8 / 27.6 / 55.2 V. Temperature compensation is included, and an optional Smart Battery Sense or BMV-712 can send battery voltage and temperature wirelessly.
Protection And No Fan
Protections include solar reverse polarity, output short circuit and over-temperature protection. Peak efficiency is 98 percent and there is no cooling fan.
Real-World Applications
-
48 V off-grid power rooms. Charge a 48 V bank from a series string, pairing with 48 V inverters.
-
RVs and trailers. Use longer panel strings to keep wire sizes manageable.
-
Boats and marine house banks. Charge a 12 V or 24 V bank from deck or arch panels.
-
Remote cabins and equipment sites. Wire panels in series over a longer run to a controller near the battery.
-
Future-proof systems. Install now on a 12 V bank and keep the controller if the bank is later changed to 24 V or 48 V.
How The MPPT 150/35 Compares To Other SmartSolar Models
Choose by solar voltage, battery voltage and current. These lines come from Victron's published specifications.
-
MPPT 100/50. 100 V input, 12 V or 24 V batteries, up to 50 A. More current at lower voltages.
-
MPPT 150/35. This controller. 150 V input, 12 V, 24 V or 48 V batteries, up to 35 A.
-
MPPT 150/45. Same 150 V input and battery voltages, up to 45 A.
Pick the 150/35 when your string voltage or 48 V battery calls for the higher input range. If a 12 V or 24 V bank needs more current from a lower-voltage array, the 100/50 delivers more amps.
Is The SmartSolar MPPT 150/35 The Right Fit For Your System
Start with your panel string. Add up the open-circuit voltage of panels in series, and correct for cold weather, since Voc rises as temperature falls. The result must stay under Victron's limits. Then check the total array watts against the nominal values for your battery voltage.
Victron's manual gives examples for a 150 V controller. For a 24 V battery, the string needs a minimum of 72 cells in series, and 144 cells gives the highest controller efficiency. For a 48 V battery, the minimum is 144 cells in series. The maximum for both is 216 cells, which is six 12 V panels or three 24 V panels. Do not use panels with optimizers, and do not ground the PV array positive or negative.
This May Be A Good Fit If
- You have a 48 V battery bank, or may build one
- Your series string will exceed what a 100 V controller can take
- You need a controller for 12 V, 24 V or 48 V in one model
- Your charge current needs are 35 A or less
- You want Bluetooth monitoring with a GX option
Common Questions
Is This The Screw Terminal Or MC4 Version?
Victron lists part number SCC115035210 with screw terminals for both the solar and battery connections, rated up to 16 mm² (6 AWG). It does not have MC4 connectors.
What Is The Maximum Solar Voltage?
Victron's datasheet says 150 V is the absolute maximum in the coldest conditions, and 145 V is the start-up and operating maximum. Keep your string's cold-weather open-circuit voltage below those limits.
What Battery Fuse Is Required?
Victron's manual lists a minimum battery fuse of 40 A and a maximum of 45 A for the MPPT 150/35.
Does It Charge Lithium Batteries?
Victron lists a fully programmable charge algorithm and says the controller can reconnect to a fully discharged lithium battery with an integrated disconnect. Check your battery maker's charge limits.
Is There A Short-Circuit Current Limit I Should Know?
Victron's datasheet and product page list a maximum PV short-circuit current of 40 A. The manual lists 35 A. Please design to the lower number or ask our team if your array is close to the limit.
What's Included
- 1 x Victron SmartSolar MPPT 150/35 Solar Charge Controller (SCC115035210)
Choose A Controller That Fits Your Whole Solar Plan
Higher-voltage strings, 48 V banks and phone monitoring all start with the right controller. The Victron SmartSolar MPPT 150/35 gives you a flexible, well-documented solar charge controller with Bluetooth and a GX option. At Outbound Power, we help customers match panels, strings and battery voltage so a system works on day one. Contact our team if you want a second look at your array before you order.
Victron SmartSolar MPPT 150/35 Solar Charge Controller Specifications
|
| Product |
| Model |
SCC115035210 |
| Name |
SmartSolar MPPT 150/35 |
| Solar Input |
| Maximum PV open circuit voltage |
150 V absolute maximum coldest conditions, 145 V start-up and operating maximum |
| Maximum PV short circuit current per tracker |
40 A (datasheet and product page); the manual lists 35 A |
| Nominal PV power at 12 V |
500 W |
| Nominal PV power at 24 V |
1,000 W |
| Nominal PV power at 36 V |
1,500 W |
| Nominal PV power at 48 V |
2,000 W |
| Number of trackers |
1 |
| Start-up PV DC voltage |
The PV voltage must exceed Vbat + 5 V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1 V |
| Battery Output |
| Battery voltage |
12 V / 24 V / 48 V (auto select); 36 V needs a software tool |
| Rated charge current |
35 A |
| Maximum efficiency |
98 % |
| Self-consumption |
12 V: 20 mA, 24 V: 15 mA, 48 V: 10 mA |
| Charge voltage absorption |
14.4 V / 28.8 V / 57.6 V (adjustable) |
| Charge voltage float |
13.8 V / 27.6 V / 55.2 V (adjustable) |
| Charge algorithm |
Multi-stage adaptive (adjustable) |
| Temperature compensation |
-16 mV/°C (12 V), -32 mV/°C (24 V), -64 mV/°C (48 V) |
| Temperature sensor |
Internal |
| Communication |
| Data communication |
Bluetooth, VE.Direct |
| Protections |
| Protections |
Output short-circuit, excessive temperature, PV reverse polarity |
| Connections |
| PV connection terminal type |
Screw terminals 16 mm² (6 AWG) |
| Battery connection terminal type |
Screw terminals 16 mm² (6 AWG) |
| Environment |
| Operating temperature range |
-30 to 60 °C (full rated output up to 40 °C) |
| Maximum humidity (non-condensing) |
95 % |
| Enclosure |
| Dimensions (h x w x d) |
130 x 186 x 70 mm (5.1 x 7.3 x 2.8 in) |
| Weight |
1.25 kg (2.8 lb) |
| Colour |
Blue (RAL 5012) |
| Protection category |
IP43 (electronic components), IP22 (connection area) |
| Stored Trends |
| Data stored |
Battery voltage, battery current, battery temperature, PV voltage, PV current, load output current |
| Data retention period |
46 d |
| Standards |
| Safety |
UL 1741, CSA C22.2, EN-IEC 62109-1 |
Victron SmartSolar MPPT 150/35 Solar Charge Controller Manual
Victron SmartSolar MPPT 150/35 Solar Charge Controller Data Sheet
Victron SmartSolar MPPT 150/35 Solar Charge Controller Dimension Drawing